Laboratory Ultrasonic cleaner

The ultrasonic cleaner is a microprocessor-controlled device that uses ultrasonic or high-frequency sound waves to clean the jewelry and other delicate items. Ultrasonic cleaning is based on the cavitation effect caused by high-frequency ultrasonic wave vibration signals in fluid. Microscopic bubbles that expand and rapidly collapse cause cavitation, which creates an effective cleaning action on the surface of the object being cleaned. Additionally, the bubbles are small enough to penetrate even microscopic crevices, cleaning them thoroughly and consistently.

$230.00

Description

Capacity2L3.2L6.5L10L15L20L22L30L
Ultrasound frequency (Khz)40KHZ40KHZ40KHZ40KHZ40KHZ40KHZ40KHZ40KHZ
Ultrasonic power80W120W180W240W360W420W480W600W
Voltage (V)AC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60HzAC220V 50Hz / 110V 60Hz
Heating power50W100W250W300W400W600W600W800W
Temperature Setting20℃-80℃20℃-80℃20℃-80℃20℃-80℃20℃-80℃20℃-80℃20℃-80℃20℃-80℃
Tank MaterialStainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304Stainless Steel SUS304
Plug Type AvailableUS or EU US or EU US or EU US or EU US or EU US or EU US or EU US or EU
Timer Setting1 - 30 mins1-99mins1-99mins1-99mins1-99mins1-99mins1-99mins1-99mins
Tank size (LxWxH mm)150x135x100240x135x100300x150x150300X240X150330X300X150330X300X200500X300X150500X300X200
Product size (LxWxH mm) 180x165x210280x180x210330x180x280330x270x280360x330x280360x330x330550x330x280530x330x330
Gross weight3kgs4kgs6.5kgs8.6kgs10.2kgs11.6kgs14.8kgs16.6kgs
Vibrator2pcs2pcs3pcs4pcs6pcs6pcs8pcs10pcs
Package Content

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

1 x Ultrasonic Cleaner

1 x Cleaning Basket

1 x Instruction Manual

Introduction and Principle

Ultrasonic cleaners are immersion cleaners that utilize high-frequency and high-intensity ultrasound waves to remove contamination from surfaces in an “ultrasonically activated liquid” (Fuchs, 2015). The machine employs the phenomenon of cavitation (microscopic bubble formation) for cleaning. It consists of a metal tank with transducers attached to the bottom or sidewall. A cleaning fluid is introduced into the tank. Ultrasonic cleaners are used in animal labs to clean surgical tools and murine implants and prepare uniform solutions by sonication. 

Ultrasonic waves are vibrations with frequencies above the audible human frequency range. They may be classified into two types: power ultrasound and diagnostic ultrasound—the introduction of ultrasonic waves in a liquid results in two major phenomena, i.e., cavitation and heating. Cavitation is described as the formation of bubbles in a liquid. Bubbles generated and collapsed by ultrasonic waves cause physical and chemical effects on liquid/liquid or solid/ liquid systems. Cavitation causes strong agitation of the liquid surfaces, thereby producing bubbles that expand and collapse, resulting in the cleaning of surfaces. These microscopic bubbles reach deep crevices and scrub for deep cleaning. The ultrasonic cleaner works best if the cavitation is fine and manifold (Wang et al., 2012). 

Two important characteristics related to cavitation that make the ultrasonic cleaner a powerful device for surface decontamination include:

  1. The cavitation bubble collapses near the surface non-symmetrically above the cavitation threshold. It causes the generation of a powerful jet directed towards the surface to be decontaminated from dirt and bacteria. The conventional ultrasonic cleaners operate within the 40kHz range. 
  2. The passage of acoustic waves through the cleaning fluid causes acoustic streaming, thereby reducing the thickness of the hydrodynamic boundary layer on any immersed surface. Consequently, the greater exposure of tiny particles on the surface to the streaming fluid can overcome the adhesion force between the surface and the particle. This phenomenon is employed in high frequency (1MHz) megasonic cleaners (Mason, 2016).

Parameters affecting the efficiency of ultrasonic cleaners

  • Cleaning Fluid

The solvent used as cleaning fluid in ultrasonic cleaners must also serve as an organic fluid that carries vibrations from the transducer to the surface being cleaned. The chemical properties of the solvent must allow it to solvate maximum possible contamination. Therefore, the cleaning fluid should have appropriate viscosity, vapor pressure, surface tension, and good cavitating properties.  

  • Bath Temperature

The bath temperature is an important parameter that affects the efficiency of ultrasonic cleaners. Temperature affects the cleaning fluid’s cavitation intensity. Maximum cavitation intensity for water is 35oC, whereas it lies between 50oC and 65oC for most aqueous cleaning solutions. The researchers suggest that reagents like acids, detergents, or alkalis added to the cleaning solutions show a stronger cleaning effect at higher temperatures. 

  • Standing Waves

The performance of ultrasonic cleaners is also affected by acoustic standing waves. A standing wave is produced when the transducer at the tank’s base generates a single frequency and hits the liquid surface before reflecting into the tank. This standing wave produces cavitation zones over the bath’s depth equivalent to “half-wave distances for the frequencies used.” A circuit is inserted into the ultrasonic cleaner to resolve the problem. This circuit causes the signal sent to the transducer to have a slight frequency variation over a given time duration, i.e., a frequency sweep. The frequency sweep ultimately prevents standing waves. 

  • Frequency

The ultrasonic cleaners worked earlier at a frequency of 20kHz, but it was audible to some young workers. Nowadays, cleaners with 40kHz frequency are used. This frequency is inaudible to researchers of all ages. Recently, megasonic cleaners operating at 1MHz frequency have been developed (Mason, 2016). 

 

Apparatus and Equipment

An ultrasonic cleaner is a stainless-steel tank with piezo-ceramic transducers. These transducers, present at the tank’s base, are connected to an ultrasonic generator. The tank contains cleaning fluid that is water in most cases. If the tank is fitted with transducers and produces cavitation, it is considered active. The tank can be activated by either inserting an immersible transducer or connecting the transducers to the bottom or sides of the tank. Consequently, the tank’s inner surfaces are energized, and cavitation is produced. 

The ultrasonic cleaners used in the laboratory have a deep-drawn tank with transducers fitted to the tank’s base or sidewall. These transducers energize the wall/bottom and transfer vibrational energy to cavitate the cleaning fluid. Ultrasonic cleaners available at Conduct Science have a 6.5L capacity and 33cm×18cm×28cm dimensions. 

 

Applications

Cleaning Murine Implants before Surgery 

Millard and Shepherd (2007) used an ultrasonic cleaner to clean a single-channel stimulator designed for chronic stimulation of neural tissue in rodents before implant. The researchers rinsed the stimulator in double-distilled water for 20 minutes and then rinsed it in an ultrasonic cleaner for 20 minutes. The cleaner had 100% ethyl alcohol. Following this, the stimulator was cleaned using double-distilled water. Then, they dried the assembly at 37oC, sterilized it, and implanted it into the animal. They observed that the stimulator successfully delivered electrical pulses to the neural tissue. 

Preparing Uniform Solutions during experiments

Keough et al. (2015) used lysolecithin as a focal injection for the demyelination and remyelination of the murine spinal cord. The researchers dissolved lysolecithin in 1% PBS (phosphate buffer saline) solution, prepared its 75µl aliquots, and stored them at -20oC. They sonicated the lysolecithin tube in an ultrasonic cleaner for half an hour to prepare a uniform solution. The frozen solution was thawed to room temperature before use.

Post-surgical Cleaning of Surgery Tools

Shih et al. (2012) studied blood flow and neurovascular coupling in rodent brains using two-photon microscopy. The researchers employed stereotaxic surgical procedures to produce cranial windows for convenient optical access to the rodent cortex. Before initiating surgery, they used an ultrasonic cleaner to clean all tools by sonication before surgery. Surgical Milk and Maxizyme were used as cleaning fluids. 

Cleaning of Endodontic Instruments 

A study conducted by Perakaki, Mellor, and Qualtrough (2007) investigated whether the ultrasonic cleaner or washer-disinfector was more effective at cleaning endodontic instruments. The results indicated that although both methods of cleaning were effective at cleaning residual debris from the endodontic files than the control group, significantly lesser residual debris was seen in the files cleaned with the ultrasonic cleaner. 

Exfoliation of Graphite Oxide (GpO) to obtain Graphene Oxide Sheets

Graphene Oxide (GO) is used in applications of biotechnology, medicine, optics, electronics, chemistry, and energy storage. It is obtained through the exfoliations of GpO, which are performed by either probe sonicators or bath sonicators (Ultrasonic Cleaner). Mellado, Figueroa, Baez, Meléndrez, and Fernández (2019) conducted an experiment to assess which cleaning method causes less damage to the graphene oxide sheet structure and morphology after exfoliation. 

X-ray diffraction, Atomic force microscopy, z-potential analysis, Scanning electron microscopy, Elemental analysis, Fourier transform infrared (FTIR) spectrometry and Raman spectroscopy were the techniques used to characterize the structure, morphology, oxygen content, exfoliation content, and surface charge of the GPO and GO samples. The results indicated that probe sonication caused deformities between the layers of the GpO samples, degrading their morphological properties and causing greater rugosity. Moreover, it caused a reduction in the number of functional groups available for further chemical transformation. On the other hand, the ultrasonic cleaner caused less damage and fewer wrinkles to the structure and morphology of the GO sheets since it was a less invasive technique and the sample temperature was easily controlled. 

Tenderization of Raw Seafood 

Chang and Wong (2018) investigated the tenderization effects of the Ultrasonic bath on farmed cobia sashimi. The ultrasonic cleaner’s tenderization effects were compared with aged treatment by analyzing the textural and biochemical characteristics of farmed cobia sashimi subjected to either treatment. The results from the aged treatment indicated that the sashimi samples’ texture reached the optimal range on day seven, but this decreased its freshness. Therefore, this treatment cannot be used in restaurants. On the other hand, tenderization with the ultrasonic bath resulted in optimal firmness after 90 minutes of treatment. The ultrasonic treatment was observed to accelerate the biochemical reactions in the samples. Therefore, it shows potential for use in the restaurant industry. 

 

Strengths and Limitations

The first and foremost advantage of ultrasonic cleaners is that microscopic bubbles produced by cavitation can reach crevices that are otherwise inaccessible with traditional cleaning methods. Secondly, ultrasonic cleaners allow robust cleaning of surfaces and require less time to clean. Thirdly, the frequency sweep used to avoid standing waves ensures uniform cleaning. Lastly, the jet formed by the collapse of cavitation bubbles provides a cleaner solvent for washing the surface (Mason, 2016).

A potential disadvantage of ultrasonic cleaners is that they comprise electronic parts that can be damaged on exposure to higher temperatures. Therefore, optimum temperature levels must be maintained while using these cleaners. 

Precautions

  • Always fill the cleaning tank to an appropriate level—lack of cleaning fluid results in decreased cavitation.
  • Do not use flammable chemicals like alcohol or gasoline. Water-based solutions must be used.
  • Do not place the parts, containers, or metal directly at the tank’s base. Always use a tray for such items or suspend them with wires. 
  • Do not pour boiled water into the bath.
  • Allow the cleaner to rest between consecutive cycles.
Summary
  • Ultrasonic cleaners are immersion cleaners that utilize high-frequency and high-intensity ultrasound waves to remove contaminants and clean surfaces. 
  • A cleaning fluid is introduced in the tank that serves as a cleaning agent and an organic fluid that carries vibrations from the transducer to the surface being cleaned.
  • Cavitation causes strong agitation of the liquid surfaces, thereby producing bubbles that expand and collapse, resulting in the cleaning of surfaces.
  • Parameters affecting the efficiency of ultrasonic cleaners include cleaning fluid, standing waves, frequency, and bath temperatures. 
  • An ultrasonic cleaner is a stainless-steel tank with piezo-ceramic transducers. These transducers, present at the tank’s base, are connected to an ultrasonic generator.
  • Ultrasonic cleaners can be used in animal labs to clean surgical tools and murine implants and prepare uniform solutions by sonication.

 

References
  1. Fuchs, F. J. (2015). Ultrasonic cleaning and washing of surfaces. In Power ultrasonics (pp. 577-609). Woodhead Publishing.
  2. Wang, W. M., Yu, B., & Zhong, C. J. (2012). Use of ultrasonic energy in the enzymatic desizing of cotton fabric. Journal of Cleaner Production33, 179-182.
  3. Mason, T. J. (2016). Ultrasonic cleaning: An historical perspective. Ultrasonics sonochemistry29, 519-523.
  4. Millard, R. E., & Shepherd, R. K. (2007). A fully implantable stimulator for use in small laboratory animals. Journal of neuroscience methods166(2), 168-177.
  5. Keough, M. B., Jensen, S. K., & Yong, V. W. (2015). Experimental demyelination and remyelination of murine spinal cord by focal injection of lysolecithin. JoVE (Journal of Visualized Experiments), (97), e52679.
  6. Shih, A. Y., Driscoll, J. D., Drew, P. J., Nishimura, N., Schaffer, C. B., & Kleinfeld, D. (2012). Two-photon microscopy as a tool to study blood flow and neurovascular coupling in the rodent brain. Journal of Cerebral Blood Flow & Metabolism32(7), 1277-1309.
  7. Perakaki, K., Mellor, A. C., & Qualtrough, A. J. (2007). Comparison of an ultrasonic cleaner and a washer disinfector in the cleaning of endodontic files. The Journal of hospital infection, 67(4), 355–359. https://doi.org/10.1016/j.jhin.2007.09.009
  8. Chang, H. C., & Wong, R. X. (2012). Textural and biochemical properties of cobia (Rachycentron canadum) sashimi tenderised with the ultrasonic water bath. Food chemistry132(3), 1340–1345. https://doi.org/10.1016/j.foodchem.2011.11.116