Serial Dilution Planner.

Calculate transfer and diluent volumes for serial dilution series. Supports fold-based and custom concentration targets. Data never leaves your browser.

PrivateData stays in your browser
LiveNo sign-up required
Open methodFormula shown on this page
CitableMethods and citation included

Calculator

Results update in place

Keep the inputs and results together. In Lab Notebook, open Inbox and choose Import item.

Complete a valid result to download.

Try it out

Load example serial dilution data to see the full workflow

Serial Dilution Series

Simple Dilution (C₁V₁ = C₂V₂)

When to use

  • Plan serial dilution series for dose-response curves, standard curves, or microbial enumeration
  • Calculate exact transfer and diluent volumes for any fold dilution factor
  • Verify pipetting volumes are within accurate range before starting benchwork
  • Generate dilution protocols for lab notebooks or SOPs
  • Quick C₁V₁ = C₂V₂ calculations for single-step dilutions

Do not use for

  • Preparing buffers at specific pH — use the Buffer Recipe Calculator instead
  • Calculating colony counts from dilution plates — use the CFU Calculator instead
  • Planning multi-component mixtures where multiple solutes interact (use a formulation tool)

Errors compound in serial dilutions

Each step uses the previous tube as its source, so a pipetting error in step 1 propagates to every subsequent step. Use calibrated pipettes, pre-wet tips, and consider independent dilutions from stock for critical reference standards.

Mix thoroughly between transfers

Incomplete mixing is the #1 source of serial dilution error. Vortex or pipette-mix 5–10 times after adding diluent, before drawing the next transfer. This is especially important for viscous solutions.

Account for the volume removed

After transferring sample to the next tube, the source tube volume decreases. If you need equal volumes for all tubes (e.g., for a plate reader), prepare extra volume in each tube or use a separate aliquot for the assay.

Use a diluent that does not affect your assay

The diluent must be compatible with your downstream assay. For cell-based assays, use serum-free media. For ELISA, use assay buffer. For microbiology, use sterile PBS or broth. Water alone may lyse cells or alter pH.

1

Method

All calculations use the dilution equation C₁V₁ = C₂V₂. In auto mode, target concentrations are generated as stock / fold^n for n = 1..N. Transfer volumes are computed as (C_target / C_source) ×\times V_total. Warnings fire when transfer < 1 µL or transfer > total volume.

2

Published

Published 2026-04-05. Calculations support planning and documentation; verify procurement decisions against manufacturer specifications or institutional SOPs.

3

How to cite

How to Cite

ConductScience Serial Dilution Planner. ConductScience, Inc. 2026. Available at: https://conductscience.com/tools/serial-dilution-calculator

Goldman E, Green LH. Practical Handbook of Microbiology. CRC Press. 2015.

Serial Dilution Fundamentals

Serial dilutions produce a geometric series of concentrations by repeatedly diluting a sample by a constant factor. The key equation is C₁V₁ = C₂V₂, where:

• C₁ = source concentration (previous tube or stock) • V₁ = volume transferred from source • C₂ = target concentration in the new tube • V₂ = total volume in the new tube

Rearranging: V₁ = (C₂ / C₁) ×\times V₂. The diluent volume is simply V₂ − V₁. Each tube in a serial dilution uses the previous tube as its source, so errors compound from step to step.

Choosing the Right Dilution Scheme

Match your dilution scheme to the experiment:

1:2 serial — Fine resolution, 8 steps cover 256-fold range. Use for: antibody titrations, MIC determinations, IC50 curves where you need dense data near the inflection.
1:10 serial — Wide range, 6 steps cover 10610^{6}-fold range. Use for: CFU enumeration, viral titers (TCID50), standard curves spanning orders of magnitude.
Half-log (1:√10) — Equal spacing on log axis, 8 steps cover ~10410^{4}-fold range. Use for: dose-response pharmacology, EC50/IC50 with 4PL fitting.
Custom — When you need specific concentrations to match previous experiments or regulatory requirements (e.g., ICH calibration levels).

Frequently asked

What is a serial dilution?
A serial dilution is a stepwise dilution of a substance in solution, where each step uses a fixed dilution factor. For example, a 1:10 serial dilution means each tube is 10-fold more dilute than the previous one. This produces a geometric series of concentrations spanning several orders of magnitude, which is essential for dose-response curves, standard curves, and microbial enumeration.
What fold dilution should I use?
The choice depends on the dynamic range you need. 1:2 dilutions give fine resolution and are common for antibody titrations and IC50 curves. 1:10 dilutions span large ranges quickly and are standard for CFU counting and viral titers. 1:3 or 1:5 dilutions offer intermediate coverage. Half-log (1:√10) dilutions are used in pharmacology for evenly-spaced points on a log-dose axis.
What is the minimum pipetting volume for accuracy?
Most standard laboratory pipettes (P2, P10, P20) lose accuracy below 1 µL. For reliable results, keep transfer volumes above 1 µL and ideally above 10% of the pipette’s maximum volume. If your calculated transfer is below 1 µL, increase the total volume per tube or use a smaller fold dilution.
When should I use half-log dilutions?
Half-log (1:√10 ≈\approx 1:3.16) dilutions place points at equal half-log intervals on a logarithmic concentration axis. They are standard in pharmacology dose-response studies because they give even spacing on log-dose plots, which is optimal for fitting sigmoidal curves (4PL/5PL) and determining EC50/IC50 values.
How do I handle viscous solutions?
Viscous solutions (e.g., glycerol stocks, serum, PEG solutions) cause inaccurate pipetting because liquid adheres to pipette tips. Use positive-displacement pipettes or reverse-pipetting technique. Pre-wet tips by aspirating and dispensing 3–5 times. Use larger total volumes to reduce the relative error from viscous transfer. Cut pipette tips can also help with very viscous samples.
What is a dilution factor?
The dilution factor is the ratio of the initial concentration to the final concentration after dilution. A 1:10 dilution has a dilution factor of 10 (the sample is 10x more dilute). The dilution factor equals the total volume divided by the volume of sample transferred. In a serial dilution, each step multiplies the cumulative dilution by the fold factor.