Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

374

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

374 results for “Power Data”

Learn how ShareScore rates datasets ↗
nasa12/100

MMS 1 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Slow Mode, 16 s Data

The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system (scm1 = - x sensor; scm2 = -z sensor; scm3 = -y sensor). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 3 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system, see SCM data product guide for details, https://lasp.colorado.edu/mms/sdc/public/datasets/fields/. This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The DSP and SCM instrument papers can be found at https://link.springer.com/article/10.1007/s11214-014-0115-x and https://link.springer.com/article/10.1007/s11214-014-0096-9, respectively. The DSP and SCM data product guides can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 1 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Slow Mode, 16 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 3 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Slow Mode, 16 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 4 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system, see SCM data product guide for details, https://lasp.colorado.edu/mms/sdc/public/datasets/fields/. This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The DSP and SCM instrument papers can be found at https://link.springer.com/article/10.1007/s11214-014-0115-x and https://link.springer.com/article/10.1007/s11214-014-0096-9, respectively. The DSP and SCM data product guides can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 4 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 2 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system, see SCM data product guide for details, https://lasp.colorado.edu/mms/sdc/public/datasets/fields/. This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The DSP and SCM instrument papers can be found at https://link.springer.com/article/10.1007/s11214-014-0115-x and https://link.springer.com/article/10.1007/s11214-014-0096-9, respectively. The DSP and SCM data product guides can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 2 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 2 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Slow Mode, 16 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 3 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 2 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Slow Mode, 16 s Data

The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system (scm1 = - x sensor; scm2 = -z sensor; scm3 = -y sensor). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
nasa12/100

MMS 1 Digital Signal Processor (DSP) Double Probe (ADP, SDP), Electric Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data

The MMS electric field power spectral density (EPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP). This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 56 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The averaging process has 48-bit accuracy to maximize the dynamic range. The amplitudes undergo a pseudo-logarithmic compression to an 8-bit number representing over 120 dB of dynamic range at ~5% precision.

restrictednotspecifiedAug 2025View details →
zenodo8/100

data set related to article Testing the Efficacy of Coping Power Universal on Behavioral Problems and Pre-academic Skills in Preschoolers

<p>This record contains rae data related to article Testing the Efficacy of Coping Power Universal on Behavioral Problems and Pre-academic Skills in Preschoolers</p>

restrictedFeb 2022View details →
zenodo8/100

data set related to article One Year Follow Up Efficacy of the Coping Power Universal and Its Relations with Teachers' Occupational Stress

<p>this record contains raw data related to article One Year Follow Up Efficacy of the Coping Power Universal and Its Relations with Teachers&#39; Occupational Stress</p>

restrictedFeb 2022View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record