Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

44

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

44 results for “IODP Expedition 350”

Learn how ShareScore rates datasets ↗
zenodo40/100

IODP Expedition 350 Magnetic remanence (SRM-longcore)

<p>Magnetic remanence was measured on section halves (and rarely on whole-round sections) using a 2G Enterprises 760R cryogenic magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization steps were performed on the samples by alternating field (AF) demagnetizer coils mounted in-line within the instrument.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Titration

<p>Various chemical constituents (most commonly chloride) were measured by titration using either an autotitrator (chloride) or a manual titrator (other compounds). Chloride was measured by ion-selective electrode and a silver nitrate titration until all chloride is bound as silver chloride.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Thermal conductivity

<p>Thermal conductivity was measured using the heated needle method in either full-space needle configuration (soft/saturated sediments) or half-space needle configuration (harder materials) of a TeKa Berlin TK-04 thermal conductivity meter. Heat is applied to the sample and then thermal equilibrium is sought. The heating and equilibration curve is reduced to derive the thermal conductivity value. Raw data are stored if a user wishes to do off-line or postexpedition reduction.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Sample report

<p>Report includes detailed information about samples taken for testing: location/depth, type/form factor, test, request number, and database identifier.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Visual core description

<p>Descriptions of samples, generally at the section half and smear slide or thin section scale, were performed by shipboard scientists and recorded in the JRSO description software. Descriptive data for both macroscopic and microscopic examination were collected in a Microscoft Excel workbook by hole. A zip file of the entire expedition&#39;s observations is also available.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Interstitial water composite report

<p>This composite report includes data from numerous interstitial water (IW) analyses (e.g., ICP-LIQUIDS and IONCHROM) in a variable set of columns. Each row combines the data from several tests (groups of measurements made on the same sample at the same time) for a particular IW sample. If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate analysis (ALKALINITY, ICP-LIQUIDS, IONCHROM, SALINITY, SPEC, TITRATOR, and potentially others). Major and minor elements were determined by inductively coupled plasma-atomic emission spectrocsopy (ICP-LIQUIDS). Cations and anions were measured by ion chromatography (IONCHROM). Complex ions were measured by colorimetric measurements using a UV-VIS spectrometer (SPEC). Alkalinity and chloride was measured by titration (ALKALINITY and TITRATOR). Dissolved carbon (DC), dissolved inorganic carbon (DIC), and dissolved organic carbon (DOC) were measured by combustion in a total organic carbon (TOC) analyzer. Salinity was measured by refractometer (SALINITY). pH was measured by ion-selective electrode as part of the alkalinity procedure and is reported in the ALKALINITY analysis.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Moisture and Density

<p>Moisture and density (MAD) data were acquired on ~10 mL sediment or rock samples by measuring three out of four material parameters: wet (saturated) mass, wet volume, dry mass, and/or dry volume after 24 h drying in a convection oven at 105 degrees C. From the moisture and volume measurements, the following phase relationships are calculated: wet and dry water content, wet bulk density, dry bulk density, grain density, porosity, and void ratio. The combination of measurements is defined by the submethod chosen: A, B, C, or D. Wet (A, B, or C) and dry (A, B, C, or D) mass is determined using motion-compensated balances. Wet volume is determined either by helium pycnometry (A) or by the sample&#39;s geometric dimensions using calipers (A or D). Dry volume (C or D) is measured by helium pycnometry. Submethods A and B are not recommended by IODP. Submethod C is suitable for saturated materials such as fine-grained sediments. Submethod D is suitable for unsaturated porous material such as certain limestones and basalts.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Carbonates composite report

<p>This composite report includes data from two analyses (total carbon from Elemental analysis [CHNS], and inorganic carbon from [Coulometer]). Each row combines the CHNS and Coulometer data from measurements made on the same sample at the same time for a particular section and section offset (depth). If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate data type (Elemental analysis and Coulometer). If the same sample was measured multiple times by any of the methods, results in the report will be combined on one line where possible. Each additional replicate result will be shown in subsequent rows and will be combined where possible. Report includes results for carbon forms: total, inorganic, calcium carbonate, and organic by difference, along with total hydrogen, nitrogen, and sulfur.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Spectrophotometry

<p>Interstitial water constitutents were measured by UV-VIS spectrometry using colorimetric methods (e.g., ammonium, nitrate, nitrite, phosphate, silica, and sulfide) by an Agilent CARY 100 UV-VIS spectrophotometer.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Scanning electron microscope images

<p>Microscopic images of discrete samples were acquired using a scanning electron microscope (SEM) and captured as image files. These files were uploaded along with a brief description and a record of the microscopic conditions when the image was taken.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 RGB channels (calculated from core photos)

<p>Red, green, and blue pixel data were extracted from Section Half Imaging Logger (SHIL) linescan images, typically binned at 0.5 cm resolution using the central 2 cm of the image.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Section summary

<p>Report includes data for individual core sections: coring/drilling depths and recovery, database identifiers for the whole section and section halves, and number of samples taken from the section before and after splitting.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 P-wave velocity bayonet (section)

<p>P-wave velocity data were measured on undisturbed section halves using pairs of piezoelectric transducers mounted in bayonets that are inserted into soft sediment along the JRSO-defined y-axis and/or z-axis. Report includes P-wave velocity in y and/or z direction, bayonet separation, traveltime between transducers, and first arrival picks.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Core orientation

<p>Core orientation data were measured downhole during advanced piston corer (APC) coring, either by Minex FlexIT or Icefield MI-5 core orientation tool. These tools measure magnetic strength and orientation, 3-axis accelerometer data, and tool temperature data.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Magnetic susceptibility (point or contact system)

<p>Magnetic susceptibility was measured on section halves on the Section Half Multisensor Logger (SHMSL) using a Bartington MS2 meter and either a MS2E or MS2K probe. Because all JRSO cores meet minimum size requirements for these two probes, MSPOINT data are corrected for volume and recorded in SI susceptibility units (x10<sup>-5</sup>).</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Magnetic susceptibility (whole round)

<p>Magnetic susceptibility was measured on whole-round sections (and rarely section halves) on the Whole-Round Multisensor Logger (WRMSL) and/or Special Task Multisensor Logger (STMSL) using a Bartington MS2 meter and a 90 mm or 80 mm MS2C loop. As volume of the sample is not controlled for this experiment, susceptibility units are recorded in instrument units and are not volume-corrected.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 Bulk Density (GRA)

<p>Gamma ray attenuation (GRA) data were acquired using a Cs-137 collimated source and a sodium iodide (thallium), or NaI(Tl), scintillation detector. The signal was calibrated using water and aluminum standards to provide a proxy for bulk density. This measurement was performed by a sensor mounted on either the Whole-Round Multisensor Logger (WRMSL) or the Special Task Multisensor Logger (STMSL); which track was used for a given data set is indicated in the data.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 ICP-AES elemental analysis (interstitial water)

<p>Elemental concentration in interstitial water samples was measured by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). Data are presented by element-wavelength pair (e.g., more than one calcium line may be reported). Elemental lines for which data do not exist for a particular expedition will not appear.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 P-wave velocity caliper (section/discrete)

<p>P-wave velocity data were measured on undisturbed section halves (JRSO-defined x-axis) and/or discrete cube and cylinder samples (x, y, or z-axis) using pairs of piezoelectric transducers mounted on a caliper system. Report includes P-wave velocity in x, y, and/or z-direction, caliper separation, traveltime between transucers, and first arrival picks.</p>

opencc-zeroMay 2015View details →
zenodo40/100

IODP Expedition 350 ICP-AES elemental analysis (solids)

<p>Elemental contents in hard rock and sediment samples was measured by inductively coupled plasma - atomic emission spectrocopy (ICP-AES). Data are presented by element-wavelength pair (e.g., more than one calcium line may be reported). Elemental lines for which data do not exist for a particular expedition will not appear.</p>

opencc-zeroMay 2015View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record