Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
761
datasets available to search
ShareScore release 0.7.1
Dataset results
761 results for “ligament”
Raw data for viscoelastic anterior cruciate ligament characteristics
<p>Here, you can find three MS Excel files containing raw, statistical and analysed data for the study of viscoelastic properties of canine cranial cruciate ligaments at slow strain rates. </p> <p>The second version of this dataset has updated Hysteresis file. </p>
Subset Data 1: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 1 to 2700)
<p><em><strong>Subset Data 1: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 1 to 2700)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 2: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 2701 to 5400)
<p><em><strong>Subset Data 2: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 2701 to 5400)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 6: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 13501 to 16200)
<p><em><strong>Subset Data 6: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 13501 to 16200)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 4: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 8101 to 10800)
<p><em><strong>Subset Data 4: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 8101 to 10800)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 5: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 10801 to 13500)
<p><em><strong>Subset Data 5: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 10801 to 13500)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 3: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 5401 to 8100)
<p><em><strong>Subset Data 3: 2700 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 5401 to 8100)</strong></em></p> <ul> <li>2700 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Subset Data 7: 607 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 16201 to 16807)
<p><em><strong>Subset Data 7: 607 Thoracolumbar Osteo-Ligamentous Spine Virtual FE Meshes (Models 16201 to 16807)</strong></em></p> <ul> <li>607 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 38MB.</li> <li>An excel file: "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "<a href="../records/8107354/files/how_to_replace_point_coordinates.mp4?download=1">how_to_replace_point_coordinates.mp4</a>". It shows how you can replace point coordinates here to the mean FE input file "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/stl.part01.rar?download=1">stl.part01.rar</a> to <a href="../records/8108354/files/stl.part09.rar?download=1">stl.part09.rar</a>).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
Repository of Thoracolumbar Osteo-Ligamentous Spine Patient-Personalised FE Meshes
<p><em><strong>Repository of Thoracolumbar Osteo-Ligamentous Spine Patient-Personalised FE Meshes:</strong></em></p> <ul> <li>42 FE input files (.inp extension, Abaqus software, Simulia) representing patient-personalised thoracolumbar spine hexahedral meshes, including point coordinates, mesh connectivity IDs and element sets. Each input file is almost 99MB (totally 3.86GB), and it includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments.</li> <li>An excel file: "<a href="../records/10994164/files/Descriptive_List%20(42_P-S_FE_Models).xlsx?download=1">Descriptive_List (42_P-S_FE_Models).xlsx</a>" reporting measured spinopelvic parameters for 42 patient-personalised FE hexahedral meshes. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort and patient-personalised FE meshes. Model ID in the excel file is correspondent to the model’s name.</li> <li>One png file: "<a href="../records/10994164/files/42_P-S.png?download=1">42_P-S.png</a>" representing the first 10 patient-personalised thoracolumbar spine hexahedral models out of 42 FE models.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="../records/10994164/files/Descriptive_List%20(42_P-S_FE_Models).xlsx?download=1">Descriptive_List (42_P-S_FE_Models).xlsx</a>" is correspondent to the same model number in the 42 stereolithography (stl) files (.stl extension) representing the thoracolumbar spine triangulated meshes (DOI: <a href="https://doi.org/10.5281/zenodo.8108354">10.5281/zenodo.8108354</a>; <a href="../records/8108354/files/42%20Patient-Specific%20stl%20files.rar?download=1">42 Patient-Specific stl files.rar</a>).</p> <p>2-Models are reconstructed thanks to the Statistical Shape Modelling (SSM) and mesh morphing techniques, i.e., spine sagittal geometrical parameters could be measured by a clinical software like sterEOS or Surgimap, then, different shape modes of morphed-mesh SSM tool could be activated in order to obtain spine deformity. Then, pros and cons analyses between patient geometrical data and synthesized geometrical information could exploit FE patient-personalised thoracolumbar osteo-ligamentous spine models.</p> <p>3- FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: jerome.noailly@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-9: model 8288 to 9288)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-9: model 8288 to 9288)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-10: model 9289 to 10289)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-10: model 9289 to 10289)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-17: model 16296 to 16807)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-17: model 16296 to 16807)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-11: model 10290 to 11290)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-11: model 10290 to 11290)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-12: model 11291 to 12291)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-12: model 11291 to 12291)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-8: model 7287 to 8287)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-8: model 7287 to 8287)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-15: model 14294 to 15294)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-15: model 14294 to 15294)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-13: model 12292 to 13292)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-13: model 12292 to 13292)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-16: model 15295 to 16295)
<p><em><strong>16807 thoracolumbar osteo-ligamentous spine virtual FE input files (part-16: model 15295 to 16295)</strong></em></p> <ul> <li>16807 FE input files representing thoracolumbar spine hexahedral models, including point coordinates. To reduce the size of shared virtual finite element (FE) models, only point coordinates are shared here. The mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" is also shared, which includes point coordinates, mesh connectivity IDs, and element sets. To generate virtual FE input files for any of the 16807 models, the corresponding shared point coordinates can be replaced into the mean FE input file (<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>). Mesh connectivity IDs, and element sets are the same in all of FE input files. Mean FE input file includes vertebras and IVDs hexahedral meshes; pelvis, sacrum, and the femoral head triangulated meshes; and ligaments. Each point coordinate file is almost 39MB.</li> <li>An excel file: "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" reporting measured spinopelvic parameters for 16807 virtual FE hexahedral models. The Excel file includes measured spinopelvic parameters (PI, PT, SS, LL, LL-PI, GT, RPV, RLL, LDI, RSA, TPA, and scoliosis cobb angle), GAP and IVD centric thickness for FE virtual cohort. Model ID in the excel file is correspondent to the model’s name.</li> <li>One video file: "how_to_replace_point_coordinates.mp4". It shows how you can replace point coordinates here to the mean FE input file "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Mean_Model%20%28Template%29.inp">Mean_Model (Template).inp</a>" in order to generate specific FE input file.</li> </ul> <p><em><strong>Notes:</strong></em></p> <p>1- Model number in "<a href="https://zenodo.org/api/files/bdc067d7-cb7d-40b7-9974-5ada43e1a0c5/Descriptive_List%20%2816807_FE_virtual_models%29.xlsx">Descriptive_List (16807_FE_virtual_models).xlsx</a>" is correspondent to the same model number in the 16807 stereolithography (stl) files (.stl extension) representing the virtual thoracolumbar spine triangulated meshes (DOI: 10.5281/zenodo.7715658; stl.part01.rar to stl.part09.rar).</p> <p>2-These point coordinates are sampled by combining the first 5 shape modes of the morphed-mesh statistical shape model in which each shape mode is discretized into 7 standard deviations: -3, -2, -1, 0, 1, 2, 3.</p> <p>3- Generated FE inp files can be opened by Abaqus 2019 and later. Any other FE software which supports .inp extension also can open the files.</p> <p><em><strong>Developed by: </strong></em>Morteza Rasouligandomani (Ph.D. student in biomedical engineering, Pompeu Fabra university, BCN Med-Tech group, DTIC department, Barcelona, Spain).</p> <p>Email contact: morteza.rasouli@upf.edu</p>
Quantitative results of the analysis of relevant components of the human scapholunate interosseous ligament (SLIL)
<p>This dataset corresponds to the quantification results carried out for the human scapholunate interosseous ligament (SLIL) and several control tissues analyzed in the manuscript entitled "Histological characterization of the human scapholunate ligament". The SLIL plays a fundamental role in stabilizing the wrist bones, and its disruption is a frequent cause of wrist arthrosis and disfunction. Traditionally, this structure is considered to be a variety of fibrocartilaginous tissue and consists of three regions: dorsal, membranous and palmar. Despite its functional relevance, the exact composition of the human SLIL is not well understood. In the present work, we have analyzed the human SLIL and control tissues from the human hand using an array of histological, histochemical and immunohistochemical methods to characterize each region of this structure. Results reveal that the SLIL is heterogeneous, and each region can be subdivided in two zones that are histologically different to the other zones. Analysis of collagen and elastic fibers, and several proteoglycans, glycoproteins and glycosaminoglycans confirmed that the different regions can be subdivided in two zones that have their own structure and composition. In general, all parts of the SLIL resemble the histological structure of the control articular cartilage, especially the first part of the membranous region (zone M1). Cells showing a chondrocyte-like phenotype as determined by S100 were more abundant in M1, whereas the zone containing more CD73-positive stem cells was D2. These results confirm the heterogeneity of the human SLIL and could contribute to explain why certain zones of this structure are more prone to structural damage and why other zones have specific regeneration potential. The original data obtained for the quantitative analyses of each component are shown in this dataset.</p>
3D models for the ligaments of the Interosseous Membrane of 5 forearms with their biomechanical simulation scenes
<p>This dataset contains a group of 15 ligaments corresponding to the five specimens (3 per forearm) modeled as 3D tetrahedral meshes. In addition, 15 simulation scenes written in SOFA framework (INRIA) are supplied to implement stretch experiments. Details about the study are provided in the technical report.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.