ToolsConductScience tool
Optogenetics & PhotometryFree in-browser calculator

Fiber Photometry Signal Calculator.

Compute ΔF/F, correct photobleaching, and generate peri-event time histograms from fiber photometry recordings. Supports TDT, Doric, and generic CSV formats.

PrivateData stays in your browser
LiveNo sign-up required
Open methodFormula shown on this page
CitableMethods and citation included

Calculator

Results update in place

When to use

  • Compute delta-F/F from raw fiber photometry fluorescence values
  • Correct photobleaching in long recording sessions using exponential decay fitting
  • Generate peri-event time histograms (PETH) aligned to behavioral events
  • Compare signal magnitude across sessions using z-score normalization
  • Export corrected traces and PETH summaries for downstream analysis

Do not use for

  • For two-photon calcium imaging ROI extraction, use Suite2p or CaImAn for spatial segmentation
  • When signal-to-noise is extremely low, consider hardware improvements first
  • As a replacement for motion artifact rejection in freely-moving recordings with severe cable noise

Always record an isosbestic control channel

The 405 nm isosbestic channel captures bleaching and motion artifacts without calcium-dependent signal changes. Without it, bleaching correction relies solely on exponential fitting, which may not capture non-exponential drift.

Baseline period selection matters

The first 10% of the trace is used as the baseline by default. If your recording starts during a behavioral epoch or after LED warm-up artifacts, crop the trace or adjust the baseline period before analysis.

Photobleaching is not always single-exponential

Some fibers and indicators exhibit bi-exponential bleaching (fast + slow component). If the R-squared of the single-exponential fit is below 0.9, consider fitting the first few minutes separately or using the isosbestic subtraction method instead.

Event timing precision limits PETH resolution

PETH alignment precision is limited by your behavioral event timestamps. If events are only accurate to plus/minus 100 ms (e.g., manual scoring), high-frequency features in the PETH may be smeared. Use hardware TTL pulses for precise alignment.

1

Method

Bleaching correction uses Levenberg-Marquardt least-squares fitting of a single exponential decay (y = a*exp(-bt) + c) to the raw signal, then subtracts the fitted curve. Delta-F/F is computed relative to the first 10% of the corrected trace as baseline. Z-scores use baseline mean and standard deviation. PETH extracts time-locked windows around each event, computes point-wise mean plus/minus SEM.

2

Published

Published 2026-04-08. Calculations support planning and documentation; verify procurement decisions against manufacturer specifications or institutional SOPs.

3

How to cite

How to Cite

ConductScience Fiber Photometry Signal Calculator. ConductScience, Inc. 2026. Available at: https://conductscience.com/tools/fiber-photometry-signal-calculator

Lerner TN, et al. Intact-brain analyses reveal distinct information carried by SNc dopamine subcircuits. Cell. 2015;162(3):622-634.

Martianova E, et al. Multi-Fiber Photometry to Record Neural Activity in Freely-Moving Animals. J Vis Exp. 2019;(152):e60278.

Frequently asked

What is delta-F/F?
Delta-F/F (delta F over F) is the standard metric for reporting fluorescence changes in fiber photometry and calcium imaging. It normalizes the signal change (F minus F0) to the baseline fluorescence (F0), yielding a dimensionless ratio that is comparable across animals and sessions.
Why correct for bleaching?
Fluorescent indicators like GCaMP undergo photobleaching, a gradual irreversible loss of fluorescence intensity during continuous excitation. This produces a slow exponential decay in the raw signal that can be mistaken for a real decrease in neural activity. Fitting and subtracting the decay curve isolates the true neural-activity-related fluctuations.
What is the isosbestic channel?
The isosbestic channel (typically 405 nm for GCaMP indicators) excites the fluorophore at a wavelength where emission does not depend on calcium binding. It captures motion artifacts and bleaching without neural signal, serving as a reference for subtraction-based correction.
How is the z-score computed?
The z-score standardizes delta-F/F values by subtracting the baseline mean and dividing by the baseline standard deviation: z = (delta-F/F minus mean_baseline) / std_baseline. This converts the trace into units of standard deviations.
What PETH window should I use?
A common choice is 1-2 seconds pre-event and 3-5 seconds post-event for GCaMP6f recordings of phasic dopamine or reward signals. Slower indicators (GCaMP6s) or sustained responses may require longer post-event windows (5-10 s).
Can I upload TDT or Doric files?
Yes. The calculator supports TDT Synapse exports (columns: time, x1_470, x1_405), Doric Neuroscience Studio exports (columns: Time(s), AIn-1, AIn-2), and generic CSV files where you specify column names. All processing happens in your browser.
325
Free tools
1,200+
Institutions
100%
Client-side
0
Uploads required