Dataset related to article "Adjuvant volumetric modulated arc therapy compared to 3D conformal radiation therapy for newly diagnosed soft tissue sarcoma of the extremities: outcome and toxicity evaluation."
<p>OBJECTIVE:</p> <p>To assess the impact of adjuvant volumetric modulated arc therapy (VMAT) compared with three-dimensional conformal radiation therapy (3DCRT) in terms of toxicity and local control (LC) in patients with soft tissue sarcoma of the extremities.</p> <p>METHODS:</p> <p>From 2004 to 2016, 109 patients were treated, initially using 3DCRT and subsequently with VMAT. Clinical outcome was evaluated by contrast-enhanced MRI, thoracic and abdominal CT 3 months after treatments and then every 6 months. Toxicity was evaluated with Common Terminology Criteria for Adverse Events scale v. 4.3.</p> <p>RESULTS:</p> <p>Patients presented Stage III soft tissue sarcoma disease (77%), localized tumor (95%) at the lower extremity (87%), adipocytic histotype (46%). Surgical resection was performed in all patients, followed by adjuvant 3DCRT in 38, and VMAT in 71. The median total dose was 66 Gy/33 fractions (range 60-70 Gy;25-35 fractions). More successful bone sparing was recorded using VMAT (<em>p</em> < 0.001). Median follow-up was 61 months, 93 and 58 months for 3DCRT and VMAT group, respectively. The 2- and 5 year LC were 95.3±2.1%, and 87.4±3.4% for the whole cohort, 92.0±4.5%, 82.9±6.4% for 3DCRT, 97.1±2.0%, 89.6±4.1% for VMAT (<em>p</em> = 0.150). On univariate and multivariate analysis the factors recorded as conditioning LC were the status of the surgical resection margins (<em>p</em> = 0.028) and the total dose delivered (<em>p</em> = 0.013).</p> <p>CONCLUSION:</p> <p>The availability of modern radiotherapy technique permit a better conformity on the target with maximum sparing of normal tissue and acceptable side-effects. VMAT is a safe and feasible treatment with limited rate of toxicity, compared to 3DCRT. Results on LC of VMAT are encouraging.</p> <p>ADVANCES IN KNOWLEDGE:</p> <p>Soft tissue sarcoma of the extremities can benefit from the use of VMAT, with a reduction of the high dose to bones to avoid radiation osteonecrosis. An adequate total dose of at least 66 Gy and a radical surgical margin allow a good local control.</p>
ShareScore
12/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 0
- Reuse readiness
- 0
- Engagement
- 4