METHODS. Bovine ilia were used in the simulations because their histological structure (a fibrolamellar cortex overlying cancellous bone26) was found to match that of the Triceratops ilium. Bone sections 10 x 50 x 縠 3.0 cm with cortices ranging from 0.5 to 5.5 mm in depth (the range of initial cortical-thickness estimates based on gross morphology) were mounted on a servohydraulic mechanical loading frame (MTS Bionix, Minneapolis) and penetrated with an aluminium-bronze T. rex tooth replica. The replica was cast from an actual adult T. rex maxillary tooth, after casts made from some ofthe deeper bite marks revealed the size and shape of the teeth that had impacted the pelvis8 • The replica was penetrated into the ilia sections at 1 mm s-1 to a depth of 11.5 mm, equivalent to the maximum depth of the deepest ilium bite mark8 • Forces were measured with an MTS 25 N strain-gauge-based axial load cell accurate to 0.2%. The forces increased with increasing penetration depth even after the cortical layer had been perforated and the underlying cancellous bone was being crushed. The increase in force with penetration depth is attributed to a greater cortical surface area coming into contact with the semi-conical penetrator tooth as it descended through the ilia. in Bite-force estimation for Tyrannosaurus rex from tooth-marked bones

METHODS. Bovine ilia were used in the simulations because their histological structure (a fibrolamellar cortex overlying cancellous bone26) was found to match that of the Triceratops ilium. Bone sections 10 x 50 x 縠 3.0 cm with cortices ranging from 0.5 to 5.5 mm in depth (the range of initial cortical-thickness estimates based on gross morphology) were mounted on a servohydraulic mechanical loading frame (MTS Bionix, Minneapolis) and penetrated with an aluminium-bronze T. rex tooth replica. The replica was cast from an actual adult T. rex maxillary tooth, after casts made from some ofthe deeper bite marks revealed the size and shape of the teeth that had impacted the pelvis8 • The replica was penetrated into the ilia sections at 1 mm s-1 to a depth of 11.5 mm, equivalent to the maximum depth of the deepest ilium bite mark8 • Forces were measured with an MTS 25 N strain-gauge-based axial load cell accurate to 0.2%. The forces increased with increasing penetration depth even after the cortical layer had been perforated and the underlying cancellous bone was being crushed. The increase in force with penetration depth is attributed to a greater cortical surface area coming into contact with the semi-conical penetrator tooth as it descended through the ilia.

ShareScore

28/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
16
Reuse readiness
0
Engagement
0

Topics