Skip to main content
ConductScienceScienceDex
zenodorestricted

Dataset related to the article "Acute outcome after a single cryoballoon ablation: Comparison between Arctic Front Advance and Arctic Front Advance PRO"

<p>This record contains raw data related to the article &ldquo;Acute outcome after a single cryoballoon ablation: Comparison between Arctic Front Advance and Arctic Front Advance PRO&rdquo;</p> <p>ABSTRACT</p> <p>BACKGROUND:</p> <p>The novel fourth-generation&nbsp;cryoballoon&nbsp;(CB4) potentially allows for enhanced catheter maneuverability and more frequent capture of pulmonary vein (PV) potentials which can be used to monitor real-time PV isolation (PVI). The aim of our study is to compare the&nbsp;acute&nbsp;procedural endpoints between the CB4 and second-generation&nbsp;cryoballoon&nbsp;(CB2).</p> <p>METHODS:</p> <p>A&nbsp;single-center retrospective chart review was used to examine 50 consecutive patients with drug-refractory atrial fibrillation undergoing CB4-based PVI. Procedural data and&nbsp;acute&nbsp;success of these patients were compared to 50 propensity-matched controls who underwent&nbsp;cryoballoon&nbsp;ablation&nbsp;procedure using CB2.</p> <p>RESULTS:</p> <p>Procedures performed with the CB4 showed significant shorter fluoroscopy time (14.8&nbsp;&plusmn; 5.5&nbsp;vs 18.0 &plusmn; 6.5&nbsp;minutes, P&nbsp;=&nbsp;.04), shorter procedure time (58.3 &plusmn; 15.7&nbsp;vs 65.3 &plusmn; 21&nbsp;minutes, P&nbsp;=&nbsp;.13), and shorter total&nbsp;ablation&nbsp;time (10.8 &plusmn; 1.5&nbsp;vs 13.8 &plusmn; 1.9&nbsp;minutes, P&nbsp;=&nbsp;.42). The real-time PVI visualization rate was 33.3% in the CB2 group and 74.7% in the CB4 group (P&nbsp;&lt;&nbsp;.001). CB4 was correlated to significant increase of&nbsp;acute&nbsp;real-time recordings with regard to all the&nbsp;single&nbsp;PV (left superior PV: 58%&nbsp;vs 84%, P&nbsp;=&nbsp;.02; left inferior PV: 26%&nbsp;vs 71%, P&nbsp;=&nbsp;.001; right superior PV 29%&nbsp;vs 61%, P&nbsp;=&nbsp;.01; and right inferior PV 19%&nbsp;vs 58%, P&nbsp;=&nbsp;.002).</p> <p>CONCLUSION:</p> <p>The CB4 was more often able to capture real-time recordings of PV potentials and the subsequent&nbsp;acute&nbsp;PV isolation.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
4
Harmonization
4
Access
0
Reuse readiness
0
Engagement
4

Dataset details

Repository
zenodo
Published
May 6, 2020
License
Not reported
DOI
10.5281/zenodo.3813427

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.