Neonatal 3T PRESS Basis Sets (MARBLE)
<p>Neonatal 3T basis sets used for the multi-site MARBLE study, simulated using Vespa. These correspond to the vendor-provided PRESS sequences used on Siemens, Philips and GE scanners, as described in Lally PJ, Montaldo P et al. Lancet Neuro 2019.</p> <p>For each vendor, a basis set is provided for each of TE=60ms and TE=288ms.</p> <p>File types:</p> <ul> <li>.RAW files (compressed into RAW.zip) - includes additional metabolites which were not included in the final basis set, but could still be useful for other neonatal MRS studies.<br> <em>*In GSH, glycine component has an additional 10Hz Gaussian broadening applied, following Kaiser LG. et al. JMR 202.2 (2010): 259-266*</em></li> <li>.in files - makebasis input file used to generate the fitting basis set from .RAW files</li> <li>.basis files - fitting basis set.<br> <em>*For MARBLE, the following metabolites were omitted from the fit with 'CHOMIT' control parameters: AcAc, Acn, Etm, Ser. The following metabolites were also combined with 'CHCOMB' due to their strong correlation during fitting: Thr+Lac, Asc+GSH*</em></li> <li>.pdf files - visualisation of the basis set components</li> </ul> <p>Some specific details:</p> <ul> <li>Narrow FWHM (1Hz Gaussian broadening) to allow accurate quantification of sharp linewidth neonatal spectra and undoped MRS phantoms.</li> <li>Two versions of each basis set: i) each metabolite has a single component in the basis set (as usual); ii) singlet peaks of NAA, Cho, Cr are separated from other resonances to allow two-point T2 relaxometry between TEs (as used for MARBLE)</li> <li>Ideal RF pulses are assumed</li> <li>TE1,TE2 are adjusted according to vendor/TE</li> <li>Reference singlet at 0ppm</li> </ul> <p><em>If using this to calculate peak area ratios at TE=288ms, multiply the LCModel provided 'concentrations' by a factor of the number of protons that contribute to each peak (i.e. 3 for NAA singlet @ 2.0ppm, 3 for Cr singlet @ 3.0ppm, 3 for Lac+Thr doublet @ 1.3ppm, 9 for Cho singlet @ 3.2ppm) - this will give you relative peak areas which are consistently scaled. </em></p> <p>Contact: p.lally [at] imperial.ac.uk</p>
ShareScore
32/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 8
- Access
- 16
- Reuse readiness
- 0
- Engagement
- 0
Topics
Dataset details
- Repository
- zenodo
- Published
- July 14, 2020
- License
- cc-by-4.0
- DOI
- 10.5281/zenodo.3946685
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.