Measuring the Optical Absorption of Single Nanowires
<p>In this work we present a method to quantitatively measure the optical absorption of single nanowires that can be applied over a wide range of temperatures and with a high enough sensitivity to enable the measurement of below-band-gap absorption (as well as the absorption of single molecules). The method is based on accurately measuring the heat flow coming from a nanowire when it is illuminated by a laser beam. We experimentally verify this method by measuring the absorption of both a zincblende and a wurtzite GaAs, a wurtzite GaP, and a superlattice <span class="MathJax_CHTML mjx-chtml"><span class="mjx-math"><span class="mjx-mrow"><span class="mjx-msub"><span class="mjx-base"><span class="mjx-mi"><span class="MJXc-TeX-main-R mjx-char">Zn</span></span></span><span class="mjx-sub"><span class="mjx-mn"><span class="MJXc-TeX-main-R mjx-char">3</span></span></span></span><span class="MJXc-space1 mjx-msub"><span class="mjx-base"><span class="mjx-mi"><span class="MJXc-TeX-main-R mjx-char">P</span></span></span><span class="mjx-sub"><span class="mjx-mn"><span class="MJXc-TeX-main-R mjx-char">2</span></span></span></span></span></span></span> nanowire. Furthermore, we find that the <span class="MathJax_CHTML mjx-chtml"><span class="mjx-math"><span class="mjx-mrow"><span class="mjx-msub"><span class="mjx-base"><span class="mjx-mi"><span class="MJXc-TeX-main-R mjx-char">Zn</span></span></span><span class="mjx-sub"><span class="mjx-mn"><span class="MJXc-TeX-main-R mjx-char">3</span></span></span></span><span class="MJXc-space1 mjx-msub"><span class="mjx-base"><span class="mjx-mi"><span class="MJXc-TeX-main-R mjx-char">P</span></span></span><span class="mjx-sub"><span class="mjx-mn"><span class="MJXc-TeX-main-R mjx-char">2</span></span></span></span></span></span></span> nanowires have the largest absorption of all these materials. We analyze the advantages and disadvantages of the method and study its range of applicability.</p>
ShareScore
28/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 0
- Engagement
- 4
Dataset details
- Repository
- zenodo
- Published
- August 16, 2020
- License
- cc-by-4.0
- DOI
- 10.5281/zenodo.4010192
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.