Aging Test - Cylindrical Cell - Part 01 - Single Cells
<p><strong>Test Sample Specifications</strong></p> <ul> <li>Nominal Capacity = 3400 mAh</li> <li>Graphite / NCA </li> <li>18650 Cell </li> </ul> <p><strong>Cycling Protocol - Normal (N) Voltage Window</strong></p> <ul> <li><em>Charge:</em> CCCV at C/2 up to 4.2 V and a 50 mA cutoff current </li> <li><em>Discharge:</em> CC at C/2 down to 2.7 V</li> </ul> <p><strong>Cycling Protocol - Reduced (R) Voltage Window</strong></p> <ul> <li><em>Charge:</em> CCCV at C/2 up to 4.0 V and a 50 mA cutoff current </li> <li><em>Discharge:</em> CC at C/2 down to 2.9 V</li> </ul> <p><strong>Cycling Life</strong></p> <p>Capacity fade and number of cycles are included in the filename.</p> <p><strong><em>Example: </em></strong></p> <ul> <li>File = 'Ba01_N20_OV1_300.xls'</li> <li>N20 = 20% Capacity fade under the normal voltage window</li> <li>Number of Cycles = 300</li> </ul>
ShareScore
12/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 0
- Reuse readiness
- 0
- Engagement
- 0
Topics
Dataset details
- Repository
- zenodo
- Published
- January 14, 2021
- License
- Not reported
- DOI
- 10.5281/zenodo.4443455
Scored with release 0.9.0