Aging Test - Cylindrical Cell - Part 02 - Modules
<p><strong>Test Sample Specifications</strong></p> <ul> <li>Configuration: 3P9S (3 cells in parallel (bank), 9 banks in series) Module</li> <li>Nominal Capacity = 10.2 Ah</li> <li>Graphite / NCA Cells</li> <li>18650 Cells </li> </ul> <p><strong>Cycling Protocol - Normal Voltage Window</strong></p> <ul> <li><em>Charge:</em> CCCV at 1C up to 37.8 V and a C/20 cutoff current </li> <li><em>Discharge:</em> CC at 1C down to 24.3 V</li> <li>Capacity Fade = 20 %</li> <li>Number of Cycles = 100</li> </ul> <p><strong>Cycling Protocol - Reduced Voltage Window</strong></p> <ul> <li><em>Charge:</em> CCCV at 1C up to 36.0 V and a C/20 cutoff current </li> <li><em>Discharge:</em> CC at 1C down to 26.1 V</li> <li>Capacity Fade = 20 %</li> <li>Number of Cycles = 135</li> </ul>
ShareScore
12/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 0
- Reuse readiness
- 0
- Engagement
- 0