zenodoopen
IODP Expedition 366 Thermal conductivity
<p>Thermal conductivity was measured using the heated needle method in either full-space needle configuration (soft/saturated sediments) or half-space needle configuration (harder materials) of a TeKa Berlin TK-04 thermal conductivity meter. Heat is applied to the sample and then thermal equilibrium is sought. The heating and equilibration curve is reduced to derive the thermal conductivity value. Raw data are stored if a user wishes to do off-line or postexpedition reduction.</p>
ShareScore
40/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 20
- Reuse readiness
- 8
- Engagement
- 0
Topics
Expedition 366MarianaSite 1200Site U1491Site U1492Site U1493Site U1494Site U1495Site U1496Site U1497Site U1498Leg 195Deep biospheresubseafloor biosphereEarth in Motionseismic zonesJOIDES ResolutionPacific plateAsut Tesoru SeamountConical SeamountFantangisna SeamountSouth Chamorro SeamountYnazao SeamountBlue Moon Seamount