DYNAMICAL REFINEMENT WITH MULTIPOLAR ELECTRON SCATTERING FACTORS
<p>The following submission contains the data collection of datasets for the sample 1-methyluracil. Data were used in publication entitled Dynamical refinement with multipolar electron scattering factors. Many crystals were measured but only the two had sufficient quality to be included in the study. Data were collected using the precession assisted 3D electron diffraction technique. All the data sets were processed with PETS2 software. Information below summarizes the data collection parameters for the data sets.</p> <p>General information:</p> <p> </p> <p>Publication title:</p> <p>Dynamical refinement with multipolar electron scattering factors</p> <p> </p> <p>Authors:</p> <p>Barbara Olech, Petr Brázda, Lukas Palatinus, and Paulina Maria Dominiak</p> <p> </p> <p>Reference to the research article:</p> <p>Olech B, Brázda P, Palatinus L, Dominiak PM Dynamical refinement with multipolar electron scattering factors<br>IUCrJ, 2024, 11, 309-324 [DOI: 10.1107/S2052252524001763]Experimental:</p> <p> </p> <p>Reference to the research grant:</p> <p>This research was funded through the OPUS LAP program by the National Science Centre, Poland (grant No. 2020/39/I/ST4/02904 awarded to PMD) and by the Czech Science Foundation (grant No 21-44862L awarded to LP).</p> <p> </p> <p>Instrument</p> <p>Transmission electron microscope FEI Tecnai G2 20</p> <p> </p> <p>Radiation source</p> <p>LaB6</p> <p> </p> <p>Accelerating voltage</p> <p>200 kV</p> <p> </p> <p>Wavelength</p> <p>0.0251 Å</p> <p> </p> <p>Probe Type</p> <p>Microdiffraction</p> <p> </p> <p>Beam Convergence</p> <p>Parallel beam, convergence <0.1mrad</p> <p> </p> <p>Precession angle</p> <p>0.7°</p> <p> </p> <p>Tilt step</p> <p>1.0°</p> <p> </p> <p>Detector</p> <p>SIS Veleta 14bit CCD camera (side-mounted)</p> <p> </p> <p>Number of pixels in the image</p> <p>2048 x 2048</p> <p> </p> <p>Effective camera length</p> <p>1200 mm</p> <p> </p> <p>Beam Diameter (crystal 1)</p> <p>1230 nm</p> <p> </p> <p>Beam Diameter (crystal 2)</p> <p>1650 nm</p> <p> </p> <p>Calibration constant</p> <p>0.001842 Å-1/pixel</p> <p> </p> <p>Compound name</p> <p>1-methyluracil</p> <p> </p> <p>Chemical composition</p> <p>C5 H6 N2 O2</p> <p> </p> <p>Sample source</p> <p>Sigma Aldrich, recrystallized from water </p> <p> </p> <p>Sample preparation</p> <p>Powder crushed in agate mortar and deposited on Cu grid with holey C film</p> <p> </p> <p>Data Type</p> <p>Electron diffraction data - 3D ED</p> <p> </p> <p>Data collection method</p> <p>Precession assisted tilt step tomography</p> <p> </p> <p>Precession angle</p> <p>0.7°</p> <p> </p> <p>Temperature (K) used during data collection</p> <p>100 K</p> <p> </p> <p>Number of crystals contributing to the data set</p> <p>2</p> <p> </p> <p>Number of experimental frames: Crystal 1</p> <p>94</p> <p> </p> <p>tilt range, tilt step: Crystal 1</p> <p>+45° to -48°, 1.00°</p> <p> </p> <p>Exposure time per frame: Crystal 1</p> <p>4000 ms</p> <p> </p> <p>Electron dose per frame: Crystal 1</p> <p>0.28 e.Å^-2</p> <p> </p> <p>Number of experimental frames: Crystal 2</p> <p>60</p> <p> </p> <p>tilt range, tilt step: Crystal 2</p> <p>-5° to +54°, 1.00°</p> <p> </p> <p>Exposure time per frame: Crystal 2</p> <p>2000 ms</p> <p> </p> <p>Electron dose per frame: Crystal 1</p> <p>0.05 e.Å^-2</p> <p> </p> <p> </p> <p>Software:</p> <p> </p> <p>Software used for the data collection</p> <p>RATS software</p> <p> </p> <p>Software used for processing</p> <p>PETS2</p> <p> </p> <p>Files and data formats</p> <p>tiff_16bit</p> <p> </p> <p>Notes:</p> <p>The software, RATS used for data collection is an in-house software developed in FZU, Prague.</p>
ShareScore
32/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 0
Dataset details
- Repository
- zenodo
- Published
- November 7, 2023
- License
- cc-by-4.0
- DOI
- 10.5281/zenodo.10079327
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.