Skip to main content
zenodoopen

Investigating the ageing process of polymer modified bitumen using a modified Thin-Film Oven Test in the aspect of recycling purpose within Weave-UNISONO 2021 project, NCN project No 2021/03/Y/ST8/00079

<div><strong>Summary:</strong></div> <div>One polymer-modified bitumen PMB 25/55-60 was tested in two stages: original and after the modified Thin-Film Oven Test (TFOT). The time ranges from 1h-5h, and temperatures from 120&deg;C-200&deg;C were used. The Fourier-Transform Infrared (FTIR) Spectroscopy and Dynamic Shear Rheometer (DSR) with parallel plates were conducted. Test temperatures range from 30&ndash;70&deg;C for a 25 mm diameter plate and 0&ndash;30&deg;C for an 8 mm plate with 10&deg;C intervals and angular frequency range of 0.1, 1.0, and 10 Hz.</div> <div>&nbsp;</div> <div>&nbsp;</div> <div><strong>The dataset includes:</strong></div> <div>Basic characteristics of bituminous binder (R&amp;B Temperatur, Penetration), CSV raw data:</div> <div> <ul> <li>01 - SP Pen.csv</li> </ul> </div> <div>&nbsp;</div> <div>Dynamic shear rheometer (Temperatures 0-70 &deg;C, Angular Frequency 0.1Hz, 1.0Hz, 10 Hz, Complex Shear Modulus, Phase Angle):</div> <ul> <li>02.1 - DSR Rheology_Unaged.csv</li> <li>02.2 - DSR Rheology_2h_140C.csv</li> <li>02.3 - DSR Rheology_2h_200C.csv</li> <li>02.4 - DSR Rheology_5h_140C.csv</li> <li>02.5 - DSR Rheology_5h_200C.csv</li> </ul> <div>&nbsp;</div> <div>FTIR - Fourier-Transform Infrared Spectroscopy&nbsp;</div> <div> <ul> <li>OPUS Spectroscopy files.zip</li> </ul> </div> <div>&nbsp;</div> <div>---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; --- &nbsp;---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---</div> <div>to open the OPUS files, please go to the &copy; Bruker webpage and download the free OPUS Viewer.</div> <div>https://www.bruker.com/en/products-and-solutions/infrared-and-raman/opus-spectroscopy-software/downloads.html</div> <div>---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; --- &nbsp;---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---</div> <div>&nbsp;</div>

ShareScore

44/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
20
Reuse readiness
8
Engagement
4

Topics