MRI raw data to publication: Fuzzy ripple artifact in high resolution fMRI: identification, cause, and mitigation.
<p>These Data are refering to the maunscript "Fuzzy ripple artifact in high resolution fMRI: identification, cause, and mitigation" authored by </p> <p>Renzo Huber1, Rüdiger Stirnberg2, A Tyler Morgan1, David A Feinberg3,4-5, Samantha J Ma6, Philipp Ehses3, Omer Faruk Gulban2,7, Kenshu Koiso2, Isabel Gephart1, Stephanie Swegle1, Susan Wardle1, Emily Ma2, Andrew Persichetti1, Alexander JS Beckett4-5, Tony Stöcker3, Nicolas Boulant8, Benedikt A Poser2, Peter Bandettini1</p> <p><strong> </strong></p> <p>1 NIMH, NIH, Bethesda, United States,</p> <p>2 German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany,</p> <p>3 Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA, United States, </p> <p>4 Advanced MRI Technologies, Sebastopol, CA, United States,</p> <p>5 CN, FPN, University of Maastricht, The Netherlands,</p> <p>6 Siemens Medical Solutions USA, Inc., Berkeley, CA, USA,</p> <p>7 Brain Innovation, Maastricht, The Netherlands,</p> <p>8 CEA, NeuroSpin, University Paris Saclay, France.</p> <p> </p> <h1>Abstract</h1> <p><strong>Purpose:</strong> High resolution fMRI is an emerging research field focused on capturing functional signal changes across cortical layers. However, the data acquisition is limited by low spatial frequency EPI artifacts; termed as Fuzzy Ripples. These artifacts limit the practical applicability of acquisition protocols with higher spatial resolution, faster acquisition speed, and they challenge imaging in lower brain areas. </p> <p><strong>Methods: </strong>We characterize Fuzzy Ripple artifacts across commonly used sequences and distinguish them from conventional EPI Nyquist ghosts, off-resonance effects, and GRAPPA artifacts. To investigate their origin, we employ dual polarity readouts.</p> <p><strong>Results: </strong>Our findings indicate that Fuzzy Ripples are primarily caused by kx-specific imperfections in gradient trajectories, which can be exacerbated by inductive coupling between third-order shims and readout gradients. We also find that these artifacts can be mitigated through complex-valued averaging of dual polarity EPI or by disconnecting the third-order shim.</p> <p><strong>Conclusion:</strong> The proposed mitigation strategies allow for overcoming current limitations in layer-fMRI protocols: </p> <p>(1) Achieving resolutions beyond 0.8mm is feasible, and even at 3T, we achieved 0.53mm voxel functional connectivity mapping. </p> <p>(2) Temporal acquisition speed can be increased to GRAPPA 8. </p> <p>(3) Sub-millimeter fMRI is achievable in lower brain areas, including the cerebellum.</p> <p> </p>
ShareScore
24/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 0
- Engagement
- 0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.