Skip to main content
zenodoopen

GC-MS raw data_Figure 6E_Lysophosphatidic Acid Shifts Metabolic and Transcriptional Landscapes to Induce a Distinct Cellular State in Human Pluripotent Stem Cells

<p><strong>Sample name</strong></p> <p>hESCs (H1 cells) were given&nbsp;treatments for&nbsp;two days and then collected for GC-MS analysis.</p> <p>E8: E8 medium</p> <p>AX: E8 + 1.6% AlbuMAX;</p> <p>BSA: E8 + 1% albumin;</p> <p>BSA+hCDL: E8 + 1% albumin + 0.1% hCDL;</p> <p>LPA+BSA: E8 + 1 &mu;M LPA + 1% albumin;</p> <p>LPA+BSA+hCDL:&nbsp;E8 + 1 &mu;M LPA + 1% albumin + 0.1% hCDL</p> <p>STD: standard lipids mixture used as reference</p> <p><strong>Extraction and Methylation</strong></p> <p>Sample preparation was conducted according to the previously reported method&nbsp;(Araujo et al., 2008)&nbsp;with the modification. Briefly, spent medium was removed, and cells were rinsed with 1 mL/well 0.9% (w/v) saline twice. Then 0.5 mL/well -80&deg;C 80% methanol was added to quench the metabolism. Five wells of cells (from 6-well plate) were scrapped off into a glass screw-cap tube. Then 4 mL heptadecanoate containing chloroform (4 &mu;g/mL, internal standard for fatty acids) was added into the tube. Vortex, and then centrifuge at 2000 rpm for 5 min. Cellular debris was carefully removed, and nitrogen blow the solution till dry. Add 1.5 mL hexane and 1.5 mL 14% boron trifluoride (BF<sub>3</sub>)/methanol solution. Seal the tube with nitrogen gas, heat it at 100&deg;C for 1 h using MK200-2 dry bath incubator (Aosheng), and then cool down to room temperature. Add 1 mL water into the tube, vortex and then centrifuge at 3000 rpm for 10 min. The upper layer was transferred into a new 1.5-mL eppendorf tube and evaporated by nitrogen gas. The residue was re-dissolved in 100 &mu;L hexane for GC-MS analysis.</p> <p><strong>GC-MS method</strong></p> <p>Samples were analyzed using an Agilent GC-MS system (Agilent) consisting of a 6890 gas chromatography and a 5973 mass spectrometer. Fatty acid methyl esters were separated by an Omegawax&trade; 250 fused silica capillary column (30 m &times; 0.25 mm i.d., 0.25 &mu;m film thickness, Supelco, Bellefonte, PA). The optimized oven temperature program was: initial temperature set at 180&deg;C and held for 3 min; ramped to 206&deg;C at 2&deg;C/min and held at 206&deg;C for 25 min, then, ramped to 240&deg;C at 10&deg;C/min and held for 5 min. Overall, the total run time was 50 min. Carrier gas was high-purity helium at a flow rate of 1.5 mL/min. Injector temperature was set at 250&deg;C. Injection volume was 2 &mu;L with a split ratio of 1:15. The mass spectrometer was operated in electron-impact (EI) mode at 70 eV ionization energy. The temperatures of quadrupole and ionization source were set at 150&deg;C and 280&deg;C, respectively. The spectra from 3 to 50 min were acquired with the&nbsp;<em>m/z</em>&nbsp;range of 35&ndash;550 at a scan rate of 0.34 s per scan.</p>

ShareScore

40/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
8
Access
16
Reuse readiness
8
Engagement
0

Topics