Data related to publication "Coherent phase transfer for real-world twin-field quantum key distribution; Supplementary Information"
<p>These files contains datasets from which the Figures appearing in the Supplementary Information have been calculated. </p> <p>Description of datasets:</p> <p>Datasets related to SupplFig1 contain two columns: Frequency in Hz and phase noise in rad^2/Hz</p> <p>Data_SupplFig1_stabilised_fringes: psd of the phase noise calculated from the interference fringes in a stabilised condition</p> <p>Data_SupplFig1_unstabilised_fringes: psd of the phase noise calculated from the interference fringes in an unstabilised condition</p> <p>Data_SupplFig1_roundtrip_sensing_laser: psd of the sensing laser signal after a round-trip in the interferometer, calculated from self-heterodyne beatnote</p> <p>Data_SupplFig1_differential_roundtrip_sensing_vs_reference_laser: psd of the difference between the round-trip self-heterodyne beatnotes at the sensing and reference laser wavelengths</p> <p>Datasets related to SupplFig2 contain two columns: time in seconds and normalised intensity (calculated as detailed in the main publication).</p> <p>Data_SupplFig2_High_power_PD_free_evol: normalised intensity of the interference signal obtained with classical power level at the source. This trace was recorded with a photodiode when no artificial phase drift was applied</p> <p>Data_SupplFig2_High_power_PD_phase_drift: normalised intensity of the interference signal obtained with classical power level at the source. This trace was recorded with a photodiode when an artificial phase drift was applied (8pi/s)</p> <p>Data_SupplFig2_High_power_SPD_free_evol: normalised intensity of the interference signal obtained with classical power level at the source. This trace was recorded on an SPD (after suitable attenuation) when no artificial phase drift was applied </p> <p>Data_SupplFig2_High_power_SPD_phase_drift: normalised intensity of the interference signal obtained with classical power level at the source. This trace was recorded on an SPD (after suitable attenuation) when an artificial phase drift was applied (8pi/s)</p> <p>Data_SupplFig2_Attenuated_SPD_free_evol: normalised intensity of the interference signal obtained with attenuated beams at the source. This trace was recorded on an SPD when no artificial phase drift was applied </p> <p>Data_SupplFig2_Attenuated_SPD_phase_drift: : normalised intensity of the interference signal obtained with attenuated beams at the source. This trace was recorded on an SPD when an artificial phase drift was applied (8pi/s)</p> <p> </p>
ShareScore
44/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 20
- Reuse readiness
- 8
- Engagement
- 4