Skip to main content
ConductScienceScienceDex
zenodorestricted

Dataset related to the article "Feasibility and Accuracy of the Automated Software for Dynamic Quantification of Left Ventricular and Atrial Volumes and Function in a Large Unselected Population"

<p>This record contains raw data related to the article &ldquo;Feasibility and Accuracy of the Automated Software for Dynamic Quantification of Left Ventricular and Atrial Volumes and Function in a Large Unselected Population&rdquo;</p> <p>Abstract</p> <p>We aimed to evaluate the feasibility and accuracy of machine learning-based automated dynamic quantification of left ventricular (LV) and left atrial (LA) volumes in an unselected population. We enrolled 600 unselected patients (12% in atrial fibrillation) clinically referred for transthoracic echocardiography (2DTTE), who also underwent 3D echocardiography (3DE) imaging. LV ejection fraction (EF), LV, and LA volumes were obtained from 2D images; 3D images were analyzed using dynamic heart model (DHM) software (Philips) resulting in LV and LA volume-time curves. A subgroup of 140 patients also underwent cardiac magnetic resonance (CMR) imaging. Average time of analysis, feasibility, and image quality were recorded, and results were compared between 2DTTE, DHM, and CMR. The use of DHM was feasible in 522/600 cases (87%). When feasible, the boundary position was considered accurate in 335/522 patients (64%), while major (n = 38) or minor (n = 149) border corrections were needed. The overall time required for DHM datasets was approximately 40 seconds. As expected, DHM LV volumes were larger than 2D ones (end-diastolic volume: 173 &plusmn; 64 vs. 142 &plusmn; 58 mL, respectively), while no differences were found for LV EF and LA volumes (EF: 55% &plusmn; 12 vs. 56% &plusmn; 14; LA volume 89 &plusmn; 36 vs. 89 &plusmn; 38 mL, respectively). The comparison between DHM and CMR values showed a high correlation for LV volumes (r = 0.70 and r = 0.82,&nbsp;<em>p</em>&nbsp;&lt; 0.001 for end-diastolic and end-systolic volume, respectively) and an excellent correlation for EF (r = 0.82,&nbsp;<em>p</em>&nbsp;&lt; 0.001) and LA volumes. The DHM software is feasible, accurate, and quick in a large series of unselected patients, including those with suboptimal 2D images or in atrial fibrillation.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
4
Harmonization
4
Access
0
Reuse readiness
0
Engagement
4

Dataset details

Repository
zenodo
Published
January 27, 2022
License
Not reported
DOI
10.5281/zenodo.5913826

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.