Sternaspis scutata µCT scan
<p>µCT scan of a specimen of <em>Sternaspis scutata</em> stained with PTA for one week. Scan and reconstruction were obtained with the following settings:</p> <p>[System]<br> Scanner=SkyScan1272<br> Instrument S/N=15H09112<br> Software Version=1.1.10<br> Source Type=HAMAMATSU_L11871_20<br> Camera Type=XIMEA xiRAY16<br> Camera Pixel Size (µm)=7.4<br> Camera X/Y Ratio=1.0058</p> <p>[Acquisition]<br> Number Of Files= 961<br> Number Of Rows= 1640<br> Number Of Columns= 2452<br> Partial Width=OFF<br> Image crop origin X=0<br> Image crop origin Y=0<br> Camera binning=2x2<br> Image Rotation=-0.00100<br> Optical Axis (line)= 890<br> Camera to Source (mm)=174.64085<br> Object to Source (mm)=82.59950<br> Source Voltage (kV)= 70<br> Source Current (µA)= 142<br> Image Pixel Size (µm)=6.999924<br> Scaled Image Pixel Size (µm)=6.999924<br> Image Format=TIFF<br> Depth (bits)=16<br> Reference Intensity=57000<br> Exposure (ms)=1238<br> Rotation Step (deg)=0.200<br> Use 360 Rotation=NO<br> Scanning position=11.719 mm<br> Frame Averaging=ON (4)<br> Random Movement=OFF (15)<br> Flat Field Correction=ON<br> FF updating interval=120<br> Geometrical Correction=ON<br> Filter=Al 0.5mm<br> Gantry direction=CC<br> Rotation Direction=CC<br> Type of Detector Motion=STEP AND SHOOT<br> Scanning Trajectory=ROUND<br> Number Of Horizontal Offset Positions=1<br> Number of connected scans=3<br> Current scan number=1<br> Number of lines to be reconstructed=1036<br> Scan duration=1h:40m:36s<br> Maximum vertical TS=5.0</p> <p>[Reconstruction]<br> Reconstruction Program=NRecon<br> Program Version=Version: 1.7.1.0<br> Reconstruction engine=InstaRecon<br> Engine version=Version: 2.0.3.7<br> Reconstruction from batch=Yes<br> Postalignment=10.00<br> Connected Reconstruction (parts)=3<br> Sub-scan post alignment [0]=10.000000<br> Sub-scan post alignment [1]=10.000000<br> Sub-scan post alignment [2]=10.000000<br> Sub-scan scan length [0]=1035<br> Sub-scan scan length [1]=1035<br> Sub-scan scan length [2]=1036<br> Used extra shift in X per scan(micron)= 0.000 -1.993 -4.803 <br> Used extra shift in Y per scan(micron)= 0.000 -25.239 -44.091 <br> First Section=63<br> Last Section=3495<br> Reconstruction duration per slice (seconds)=0.349107<br> Total reconstruction time (2071 slices) in seconds=723.000000<br> Section to Section Step=1<br> Sections Count=3433<br> Result File Type=TIF<br> Result File Header Length (bytes)=12<br> Result Image Width (pixels)=2152<br> Result Image Height (pixels)=2056<br> Pixel Size (µm)=6.99992<br> Reconstruction Angular Range (deg)=192.20<br> Use 180+=OFF<br> Angular Step (deg)=0.2000<br> Smoothing=3<br> Smoothing kernel=2 (Gaussian)<br> Ring Artifact Correction=20<br> Draw Scales=OFF<br> Object Bigger than FOV=OFF<br> Reconstruction from ROI=ON<br> ROI Top (pixels)=2282<br> ROI Bottom (pixels)=223<br> ROI Left (pixels)=214<br> ROI Right (pixels)=2369<br> ROI reference length=2452<br> Filter cutoff relative to Nyquist frequency=100<br> Filter type=0<br> Filter type description=Hamming (Alpha=0.54)<br> Undersampling factor=1<br> Threshold for defect pixel mask (%)=0<br> Beam Hardening Correction (%)=54<br> CS Static Rotation (deg)=78.89<br> Minimum for CS to Image Conversion=0.003750<br> Maximum for CS to Image Conversion=0.105554<br> HU Calibration=OFF<br> BMP LUT=0<br> Cone-beam Angle Horiz.(deg)=11.863247<br> Cone-beam Angle Vert.(deg)=7.950323<br> Automatic matching in Z=50<br> Automatic matching in X/Y=50<br> Automatic matching in rotation=0.000000<br> Automatic fusion=1<br> <br> Data size has been reduced by conversion from 16-bit to 8-bit and decreasing the scale of the images.</p>
ShareScore
32/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 0
Dataset details
- Repository
- zenodo
- Published
- February 24, 2022
- License
- cc-by-4.0
- DOI
- 10.5281/zenodo.6275178
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.