Brewer Global Iradiance (GI) total ozone data at two Norwegian sites (2000 to 2020)
<p>Total column ozone (TCO) derived from Global Irradiance (GI) measurements from the Brewer instruments B042 in Oslo (Norway) and B104 in Andøya (Norway) from 01-01-2000 to 31-12-2020.</p> <p>The data consist of daily values averaged +/-2 hours around local noon.</p> <p>GI calibrations where performed with a clear sky direct sun (DS) measurements in 06-2001, 08-2014, 08-2016, 08-2018, and 08-2019 at Andøya, and in 08-2005, 06-2019, and 08-2019 at Oslo. The data has been calibrated with standard lamp measurements and have been homogenized with DS measurements as a function of clouds and solar zenith angle.</p> <p>The method, calibration, and homogenization is described by Bernet et al. (2022) (Appendix A).</p> <p>Responsible institute: NILU - Norwegian Institute for Air Research</p> <p>Funded by the Swiss National Science Foundation and the Norwegian Environment Agency</p> <p>Bernet, L., Svendby, T., Hansen, G., Orsolini, Y., Dahlback, A., Goutail, F., Pazmiño, A., Petkov, B., and Kylling, A., Total ozone trends at three northern high-latitude stations, 2022.</p>
ShareScore
44/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 20
- Reuse readiness
- 8
- Engagement
- 4