Hyperspectral X-ray CT datasets of three chemical phantoms

<p><strong>General Data description:</strong></p> <p>The following are hyperspectral (energy-resolved) X-ray CT datasets for a set of chemical phantom samples, each containing multiple phases of an aqueous contrast agent at different concentrations. All scans were acquired with an energy-sensitive HEXITEC detector in the Henry Moseley X-ray Imaging Facility at The University of Manchester.</p> <p>The following data contains all the files necessary for reconstruction of each dataset. The phantom samples were produced as they each offer a distinct spectral marker which, when measured by an energy-sensitive detector, may be used as a form of calibration for spectral analysis. The phantoms were for the common contrast agents of I<sub>2</sub>KI, BaSO<sub>4</sub> and PTA.</p> <p><strong>File descriptions:</strong></p> <p>Contained are four MATLAB (.mat) data files, as well as three text (.txt) metadata files.</p> <p>Iodine_Phantom_scan_parameters.txt provides the full sample and detector geometry of the scan acquisition for the I<sub>2</sub>KI phantom. The concentrations for the iodine phases were 25, 50, 76 and 101 mg/ml of aqueous I<sub>3</sub><sup>-</sup> ions respectively.</p> <p>Barium_Phantom_scan_parameters.txt provides the full sample and detector geometry of the scan acquisition for the BaSO<sub>4</sub> phantom. The concentrations for the BaSO<sub>4</sub> phases were 100, 200 and 400 mg/ml of BaSO<sub>4</sub> respectively.</p> <p>Tungsten_Phantom_scan_parameters.txt provides the full sample and detector geometry of the scan acquisition for the PTA phantom. The concentrations for the PTA phases were 50, 100 and 200 mg/ml of PTA respectively.</p> <p>Iodine_phantom_sinogram.mat contains the full 4D sinogram constructed following flatfield normalisation of the raw projection data for the I<sub>2</sub>KI phantom. The 4D array contains the total number of energy channels acquired during scanning, followed by vertical and horizontal pixel number, and finally total projections angles acquired. In addition, a ring artefact reduction filter was applied, as well as a centre-of-rotation correction.</p> <p>Barium_phantom_sinogram.mat contains the full 4D sinogram constructed following flatfield normalisation of the raw projection data for the BaSO<sub>4</sub> phantom. The 4D array contains the total number of energy channels acquired during scanning, followed by vertical and horizontal pixel number, and finally total projections angles acquired. In addition, a ring artefact reduction filter was applied, as well as a centre-of-rotation correction.</p> <p>Tungsten_phantom_sinogram.mat contains the full 4D sinogram constructed following flatfield normalisation of the raw projection data for the PTA phantom. The 4D array contains the total number of energy channels acquired during scanning, followed by vertical and horizontal pixel number, and finally total projections angles acquired. In addition, a ring artefact reduction filter was applied, as well as a centre-of-rotation correction.</p> <p>Energy_axis.mat provides a direct conversion between the energy channels, and the energies (in keV) that they correspond to, following a calibration procedure prior to scanning.</p>

ShareScore

48/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
20
Reuse readiness
8
Engagement
8

Topics