Measurement report: Radiative efficiencies of (CF3)2CFC, CF3OCFCF2, and CF3OCF2CF3

<p>Absorption cross-sections of emerging greenhouse gases (GHG) were measured to estimate the radiative efficiency using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer&ndash;Lambert parameters of absorber pressure, temperature, and optical path length (OPL) were accurately determined to be traceable to the primary standards. The OPL of the multipass cell mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N<sub>2</sub>O absorptions was found to be in the range of 2217.4&ndash;2219.0 cm<sup>-1</sup>, with a spectral resolution of 0.026 cm<sup>-1</sup>, yielding a ratio of OPLs that falls between the multipass cell and reference cell. This cell-to-cell comparison method is free from the uncertainty in the referring line strength, which reduced the calibration uncertainty compared with the direct line-strength referring method. With the OPL-calibrated multipass cell (3.169 &plusmn; 0.079 m), the absorption cross-sections were measured at low absorber pressures with a spectral resolution of 2 cm<sup>-1</sup>, integrated at 10 cm<sup>-1</sup> intervals, and multiplied by the new narrow band model to yield the radiative efficiencies. The radiative efficiency values of CF<sub>4</sub>, SF<sub>6</sub>, and NF<sub>3</sub> were evaluated to be 0.085 &plusmn; 0.002, 0.573 &plusmn; 0.016, and 0.195 &plusmn; 0.008 W m<sup>-2</sup> ppb<sup>-1</sup>, respectively, which are consistent with previously reported values. For the emerging GHGs, the radiative efficiency values were determined to be 0.201 &plusmn; 0.008 Wm<sup>-2</sup>ppb<sup>-1</sup> for heptafluoroisobutyronitrile (CF<sub>3</sub>)<sub>2</sub>CFCN; commercially referred to as <em>Novec-4710</em>), 0.328 &plusmn; 0.013 Wm<sup>-2</sup>ppb<sup>-1</sup> for perfluoro methyl vinyl ether (CF<sub>3</sub>OCFCF<sub>2</sub>; PMVE), and 0.544 &plusmn; 0.022 Wm<sup>-2</sup>ppb<sup>-1</sup> for 1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane (CF<sub>3</sub>OCF<sub>2</sub>CF<sub>3</sub>; PFMEE).</p>

ShareScore

40/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
20
Reuse readiness
8
Engagement
0

Topics

Dataset details

Repository
zenodo
Published
September 30, 2022
License
cc-by-4.0
DOI
10.5281/zenodo.7132869

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.