3D ED dataset of 1,3,5-triphenylbenzene
<p>Continuous rotation 3D ED data collection of 1,3,5-triphenylbenzene (TPB). See the following table for additional details.</p> <table> <tbody> <tr> <td><strong>Project name</strong></td> <td>TPB_25032024</td> </tr> <tr> <td> </td> <td> </td> </tr> <tr> <td><strong>Instrumental</strong></td> <td> </td> </tr> <tr> <td>Instrument</td> <td>ELDICO <em>ED-1</em> electron diffractometer</td> </tr> <tr> <td>Electron source</td> <td> <p>LaB<sub>6</sub></p> </td> </tr> <tr> <td>Electron energy </td> <td>160 kV</td> </tr> <tr> <td>Wavelength</td> <td>0.02851 Å</td> </tr> <tr> <td>Beam mode</td> <td>pseudo-parallell</td> </tr> <tr> <td>Beam diameter</td> <td>750 nm</td> </tr> <tr> <td>Detector</td> <td>Dectris QUADRO</td> </tr> <tr> <td>Detetor no. of pixels</td> <td>512 x 512</td> </tr> <tr> <td>Detetor pixel size</td> <td>75 µm</td> </tr> <tr> <td>Data collection mode</td> <td>continuous rotation</td> </tr> <tr> <td>Measurement temperature</td> <td>298 K</td> </tr> <tr> <td>Instrument control software</td> <td>eldix, Version 4.3.1</td> </tr> <tr> <td> </td> <td> </td> </tr> <tr> <td><strong>Sample</strong></td> <td> </td> </tr> <tr> <td>Compound</td> <td>1,3,5-triphenylbenzene</td> </tr> <tr> <td>Chemical formula</td> <td> <p>C<sub>24</sub>H<sub>18</sub></p> </td> </tr> <tr> <td>Sample source</td> <td>commercial, 99+% purity</td> </tr> <tr> <td>Grid</td> <td>amorphous carbon on copper</td> </tr> <tr> <td>Sample preparation</td> <td>grinding of the sample between microscope slides and dry preparation on the grid</td> </tr> <tr> <td> </td> <td> </td> </tr> <tr> <td><strong>Files and data formats</strong></td> <td> </td> </tr> <tr> <td>Diffraction frame folders</td> <td>03, 06, 07, 08</td> </tr> <tr> <td>Diffraction frame format</td> <td>.cbf</td> </tr> <tr> <td>Additional files</td> <td>subfolders with STEM images of the particles at different tilt angles</td> </tr> <tr> <td>Comments</td> <td>folder _full.zip contains the full measurement data, folder _recommended.zip already has frames removed which are affected by other crystals in the beam, shadowing by the grid bars, or beam damage</td> </tr> </tbody> </table>
ShareScore
36/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 0
Dataset details
- Repository
- zenodo
- Published
- May 5, 2024
- License
- cc-by-4.0
- DOI
- 10.5281/zenodo.11119251
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.