Experimental dataset: stationary images for digital image correlation uncertainty quantification
<div>----------------------------------------------------------------------------------------------------------------------------------------------------------------------</div> <div>-------------------------------------------------------------------------------- <strong>SUMMARY</strong> ---------------------------------------------------------------------------</div> <div>----------------------------------------------------------------------------------------------------------------------------------------------------------------------</div> <div> </div> <div>Stereo-DIC 5 MPx system was used to capture sets of stationary images for quantification of DIC uncertainties.</div> <div> </div> <div>----------------------------------------------------------------------------------------------------------------------------------------------------------------------</div> <div>-------------------------------------------------------------------------------- <strong>FOLDERS </strong>---------------------------------------------------------------------------</div> <div>----------------------------------------------------------------------------------------------------------------------------------------------------------------------</div> <div> </div> <div><strong>Image sets:</strong> </div> <div> </div> <div><strong>Set 1: </strong>100 stationary images with cross polarisation to reduce effect of specular reflection. Test sample clamped in the clamps of a uniaxial tensile test bench.</div> <div><strong>Set 2: </strong>Same as set 1, but test sample unclamped at the bottom, displaced by 1 mm vertically. Meant to introduce rigid body motion into teh stationary images. </div> <div>For investigation of the impact of cross-polarisation: image gradients made similar as much as possible by adjusting exposure time and apetrture. </div> <div><strong>Set 3:</strong> With cross polarisation - 100 stationary images.</div> <div><strong>Set 4:</strong> Without cross polarisation - 100 stationary images.</div> <div> </div> <div>Images for stereo calibration:</div> <div> </div> <div><strong>Calib_sets_1_2: </strong>Calibration images for sets 1 and 2 mentioned above </div> <div><strong>Calib_sets_3:</strong> Calibration images for set 3 mentioned above </div> <div><strong>Calib_sets_4: </strong>Calibration images for set 4 mentioned above </div> <div> </div> <div>----------------------------------------------------------------------------------------------------------------------------------------------------------------------</div> <div>------------------------------------------------------------------------ <strong>SUPPORTING NINFORMATION </strong>--------------------------------------------------------------------</div> <div>---------------------------------------------------------------------------------------------------------------------------------------------------------------------- </div> <div> </div> <div>Image folder for each set contains an *.xaml file with image capture settings.</div> <div>Each calibration image folder contains a *.caldat file with intrinsic and extrinsic stereo camera parameters identified by MatchID 2024.2 DIC package.</div>
ShareScore
32/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 4
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 0