Skip to main content
ConductScienceScienceDex
zenodorestricted

Open 1.0-T versus closed 1.5-T cardiac MR: Image quality assessment

<p>Dataset from&nbsp;Al&igrave; M, Monti CB, Gold B, Lastella G, Papa S, Sardanelli F, Secchi F. Open 1.0-T versus closed 1.5-T cardiac MR: Image quality assessment. Clin Imaging. 2020 Dec;68:102-107. doi: 10.1016/j.clinimag.2020.06.019. Epub 2020 Jun 15. PMID: 32585415.</p> <p><strong>Abstract</strong></p> <p><strong>Purpose:&nbsp;</strong>The aim of this paper was to compare the open 1-T (O-1T) versus the closed 1.5-T (C-1.5T) cardiac magnetic resonance (MR).</p> <p><strong>Patients/methods:&nbsp;</strong>The MR examinations of two concurrent cohorts (each including 100 subjects) of patients with suspected or known cardiac disease were reviewed. Such examinations were obtained using O-1T or C-1.5T MRI. The bright-blood cine, T1-weighted (T1), T2-weighed short-tau inversion recovery (T2-STIR), late gadolinium enhancement (LGE) sequences were performed. Signal-to-noise ratio of blood (SNRb) or myocardium (SNRm), and contrast-to-noise ratio of myocardium (CNRm) were calculated. Subjective image quality (SIQ) of each sequence was graded as 0 = poor, 1 = intermediate, or 2 = optimal. Each examination was considered as diagnostic when the report answered the clinical question.</p> <p><strong>Results:&nbsp;</strong>C-1.5T was better than O-1T on cine for SNRb(median 172 versus 452), SNRm(71 versus 160) and CNRm (107 versus 265) and on T2-STIR for SNRb(10 versus 29), SNRm(74 versus 261) and CNRm(-67 versus -233)(P &lt; 0.001). On LGE, SNRm was higher with O-1T than for C-1.5T (312 versus 79, P &lt; 0.001) while CNR was lower (158 versus 389; P &lt; 0.001). No significant differences were found for SNRb on LGE and both SNRm and CNRm on T1 (P &ge; 0.215). SIQ of O-1T was not significantly different from that of C-1.5T for both R1 and R2 for cine, T1, and LGE (P &ge; 0.157); for T2-STIR, SIQ of O-1T was significantly lower (P = 0.003). R1-R2 concordance was almost perfect (&kappa; = 0.816-0.894), and all examinations were diagnostic.</p> <p><strong>Conclusion:&nbsp;</strong>Even though quantitative measurements mostly favored C-1.5T, the SIQ of O-1T was not significantly different for any sequence, with the only exception of T2-STIR.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
0
Reuse readiness
0
Engagement
0

Topics

Dataset details

Repository
zenodo
Published
July 29, 2021
License
Not reported
DOI
10.5281/zenodo.5147952

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.