Skip to main content
zenodorestricted

Diagnosis of left atrial appendage thrombus in patients with atrial fibrillation: delayed contrast-enhanced cardiac CT

<p>Dataset from the article&nbsp;Spagnolo P, Giglio M, Di Marco D, Canna&ograve; PM, Agricola E, Della Bella PE, Monti CB, Sardanelli F. Diagnosis of left atrial appendage thrombus in patients with atrial fibrillation: delayed contrast-enhanced cardiac CT. Eur Radiol. 2021 Mar;31(3):1236-1244. doi: 10.1007/s00330-020-07172-2. Epub 2020 Sep 4. PMID: 32886202; PMCID: PMC7880950.</p> <p><strong>Abstract</strong></p> <p><strong>Objectives:&nbsp;</strong>The current reference standard for diagnosing LAA thrombi is transesophageal echocardiography (TEE), a semi-invasive technique. We aimed to devise an optimal protocol for cardiac computed tomography (CCT) in diagnosing left atrial appendage (LAA) thrombus in patients with atrial fibrillation (AF), using TEE as reference standard.</p> <p><strong>Methods:&nbsp;</strong>Two hundred sixty consecutive patients referred for radiofrequency ablation for AF were prospectively enrolled. All patients underwent CCT and TEE within 2 hours. The CCT protocol included one standard angiographic phase and three delayed acquisitions at 1-, 3-, and 6-min after contrast injection. Thrombi were defined as persisting defects at 6-min delayed acquisition.</p> <p><strong>Results:&nbsp;</strong>TEE demonstrated spontaneous contrast in 52 (20%) patients and thrombus in 10 (4%). In 63 patients (24%), CCT demonstrated LAA early filling defects at angiographic phase. Among them, 15 (6%) had a persistent defect at 1-min, 12 (5%) at 3-min, and 10 (4%) at 6-min. All 10 thrombi diagnosed on TEE were correctly identified by delayed CCT, without any false positives. For all phases, sensitivity and negative predictive were 100%. Specificity increased from 79% for the angiographic phase to 100% at 6-min. Positive predictive value increased from 16% to 100%. Estimated radiation exposure was 2.08 &plusmn; 0.76 mSv (mean &plusmn; standard deviation) for the angiographic phase and 0.45 &plusmn; 0.23 mSv for each delayed phase.</p> <p><strong>Conclusion:&nbsp;</strong>A CCT protocol adding a 6-min delayed phase to the angiographic phase can be considered optimized for the diagnosis of LAA thrombi, with a low radiation dose.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
0
Reuse readiness
0
Engagement
0

Topics