Psoas Cross-Sectional Measurements Using Manual CT Segmentation before and after Endovascular Aortic Repair (EVAR).
<p>Monti CB, Righini P, Bonanno MC, Capra D, Mazzaccaro D, Giannetta M, Nicolino GM, Nano G, Sardanelli F, Marrocco-Trischitta MM, Secchi F. Psoas Cross-Sectional Measurements Using Manual CT Segmentation before and after Endovascular Aortic Repair (EVAR). J Clin Med. 2022 Jul 12;11(14):4023. doi: 10.3390/jcm11144023. PMID: 35887786; PMCID: PMC9325160.</p> <p>Abstract</p> <p>Sarcopenia has been associated with an increased incidence of adverse outcomes, including higher mortality, after endovascular aortic repair (EVAR). We aim to use computed tomography (CT) to quantify changes in total psoas muscles area (PMA) and psoas muscle density (PMD) after EVAR, and to evaluate the reproducibility of both measurements. PMA and PMD were assessed via manual segmentation of the psoas muscle on pre- and post-operative CT scans belonging to consecutive patients who underwent EVAR. Wilcoxon test was used to compare PMA and PMD before and after EVAR, and inter- and intra-reader agreements of both methods were evaluated through Bland-Altman analysis. A total of 50 patients, 42 of them males (84%), were included in the study. PMA changes from 1243 mm<sup>2</sup> (1006-1445 mm<sup>2</sup>) to 1102 mm<sup>2</sup> (IQR 937-1331 mm<sup>2</sup>), after EVAR (<em>p</em> &lt; 0.001). PMD did not vary between pre-EVAR (33 HU, IQR 26.5-38.7 HU) and post-EVAR (32 HU, IQR 26-37 HU, <em>p</em> = 0.630). At inter-reader Bland-Altman analysis, PMA showed a bias of 64.0 mm<sup>2</sup> and a coefficient of repeatability (CoR) of 359.2 mm<sup>2</sup>, whereas PMD showed a bias of -2.43 HU and a CoR of 6.19 HU. At intra-reader Bland-Altman analysis, PMA showed a bias of -81.1 mm<sup>2</sup> and a CoR of 394.6 mm<sup>2</sup>, whereas PMD showed a bias of 1.41 HU and a CoR of 6.36 HU. In conclusion, PMA decreases after EVAR. A good intra and inter-reader reproducibility was observed for both PMA and PMD. We thus propose to use PMA during the follow-up of patients who underwent EVAR to monitor muscle depletion after surgery.</p>
ShareScore
12/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 0
- Reuse readiness
- 0
- Engagement
- 0
Topics
Dataset details
- Repository
- zenodo
- Published
- January 30, 2023
- License
- Not reported
- DOI
- 10.5281/zenodo.7588838
Scored with release 0.9.0
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.