Skip to main content
zenodorestricted

Fast Approximate Quantification of Endovascular Stent Graft Displacement Forces in the Bovine Aortic Arch Variant

<p>Sturla F, Caimi A, Romarowski RM, Nano G, Glauber M, Redaelli A, Votta E, Marrocco-Trischitta MM. Fast Approximate Quantification of Endovascular Stent Graft Displacement Forces in the Bovine Aortic Arch Variant. J Endovasc Ther. 2022 May 19:15266028221095403. doi: 10.1177/15266028221095403. Epub ahead of print. PMID: 35588222.</p> <p>Abstract</p> <p><strong>Purpose:&nbsp;</strong>Displacement forces (<strong><em>DF</em></strong>s) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of&nbsp;<strong><em>DF</em></strong>s merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure.</p> <p><strong>Materials and methods:&nbsp;</strong>We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the &quot;bovine&quot; aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute&nbsp;<strong><em>DF</em></strong>s within the aortic proximal landing zones. To quantify fast-approximate&nbsp;<strong><em>DF</em></strong>s, the wall shear stress contribution to the&nbsp;<strong><em>DF</em></strong>&nbsp;was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also,&nbsp;<strong><em>DF</em></strong>&nbsp;values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction (<strong><em>EST</em></strong>).</p> <p><strong>Results:&nbsp;</strong>Fast-approximate approach consistently reflected (r<sup>2</sup>=0.99, p&lt;0.0001) the&nbsp;<strong><em>DF</em></strong>&nbsp;pattern obtained by CFD, with a -1.1% and 0.7&deg; bias in&nbsp;<strong><em>DF</em></strong>s magnitude and orientation, respectively. The normalized&nbsp;<strong><em>EST</em></strong>&nbsp;progressively increased (p&lt;0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p&lt;0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate&nbsp;<strong><em>EST</em></strong>&nbsp;was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology.&nbsp;<strong><em>S</em></strong>&nbsp;showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of&nbsp;<strong><em>DF</em></strong>&nbsp;impact on the thoracic aortic wall.</p> <p><strong>Conclusion:&nbsp;</strong>Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
0
Reuse readiness
0
Engagement
0

Topics

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.