Simulated shielding performance of 1296 four-layer permutations of six common satellite and radiation shielding materials against trapped particles on GTO
<p>The 4Layer.csv file contains ionizing dose results of simulating the shielding performance of all 1296 four-layer permutations of six common satellite and radiation shielding materials against trapped particles on GTO.<br> The materials are the aluminium alloy 7075 (Al_7075), polyethylene (G4_POLYETHYLENE), kevlar (G4_KEVLAR), tungsten (G4_W), stainless steel (G4_STAINLESS_STEEL) and the circuit board composite material FR4 (FR4).<br> The particle spectra used for this simulation are provided in the files AE9500keV.mac and AP910MeV.mac.<br> The simulated geometry is provided in the file 4Layer.gdml.</p> <p>The particle spectra were generated with the AE9/AP9 models on SPENVIS, with electron energies starting at 500 keV and proton energies starting at 10 MeV.<br> The simulation was performed with GRAS / Geant4 with the FTFP_BERT physics model using 6.6e+10 electrons and 3.8e+09 protons directed against slabs of shielding materials of 1.5 g/cm2 total depth with each of the four layers being 0.375 g/cm2 in depth.<br> The ionizing dose is recorded in 0.5mm thick silicon plates behind the shielding plates.<br> <br> Column A: ID of the material combination<br> Column B: Name of the top layer material.<br> Column C: Name of the second layer material.<br> Column D: Name of the third layer material.<br> Column E: Name of the bottom layer material.<br> Column F: Ionizing dose due to electrons in units of kRad per month.<br> Column G: Absolute statistical error in the electron dose in kRad per month.<br> Column H: Ionizing dose due to protons in kRad per month.<br> Column I: Absolute statistical error in the proton dose in kRad per month. <br> Column J: Total ionizing dose from electrons and protons in kRad per month.<br> Column K: Absolute statistical error in the total ionizing dose in kRad per month. <br> Column L: Relative statistical error of the total ionizing dose in per cent.<br> Column M: Rank of the material combination sorted from lowest total ionizing dose to highest.<br> Column N: Rank of the material combination sorted from lowest electron dose to highest.<br> Column O: Rank of the material combination sorted from lowest proton dose to highest.</p> <p>All dose values are rounded according to their uncertainty.</p>
ShareScore
44/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 20
- Reuse readiness
- 8
- Engagement
- 4