Skip to main content
ConductScienceScienceDex
zenodorestricted

raw dataset related to the article "Patent foramen ovale closure with the Occlutech Figulla Flex II device: A long-term (up to 10-years) follow-up"

<p><strong>Abstract</strong></p> <p><strong>Background.</strong> Percutaneous closure represents the first line of treatment In patients with cryptogenic stroke and documented patent foramen ovale (PFO). Scarce data report the long-term outcomes of patients undergoing PFO closure with the Figulla Flex II device (Occlutech, Germany).</p> <p><strong>Methods</strong>. Consecutive patients undergoing PFO closure with a Figulla Flex II device at a single, high-volume Institution were included. Baseline clinical and procedural features were collected and patients were followed up for up to 10 years. The device&#39;s long-term safety was assessed, as well as mortality, recurrent cerebrovascular events, new-onset atrial fibrillation (AF) and residual shunt.</p> <p><strong>Results.</strong> Overall, 442 patients were included. The main indication for PFO closure was cryptogenic stroke/transitory ischemic attack (65.5%), followed by migraine (21.7%), silent lesions at MRI (10.8%), and decompression disease (2.0%). Atrial septal aneurysm was present in 20.8% of cases, Eustachian valve in 9.0%, Chiari network in 19.9%. The most frequently implanted device was the 23/25 mm (49.5% of cases). One procedural failure due to device embolization; in-hospital complications occurred in 15 cases (3.4%; 4 minor access site complications, 11 transient supraventricular tachycardias (SVT)/AF). After a follow-up of 9.2 years, 2 patients suffered recurrent TIA (with no residual R-L shunt detected). A moderate or severe residual shunt was observed in 3 patients after discharge.&nbsp;</p> <p><strong>Conclusions</strong>. Figulla Flex II devices for PFO closure are associated with high procedural success and low incidence of adverse events even at long-term follow-up.</p>

ShareScore

12/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
0
Reuse readiness
0
Engagement
0

Topics

Dataset details

Repository
zenodo
Published
June 8, 2023
License
Not reported
DOI
10.5281/zenodo.8019610

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.