Proton Therapy Treatment Simulations with the Bergen DTC Prototype for Range Verification
<p>This dataset contains proton therapy Monte Carlo simulations using GATE (Jan et al. 2004) version 9.2 and Geant4 (Agostinelli et al. 2003; Allison et al. 2006; Allison et al. 2016) version 11.0.0. The treatment targets are the pediatric head phantom 715-HN by CIRS Inc. (Norfolk, VA, United States), digitized by Giacometti et al. (2017), and The Visible Human Female (VHF) head, courtesy of the U.S. National Library of Medicine, resampled to 1 mm voxels and scaled down to 80%. Distal to the phantom, is a simplified geometry of the digital tracking calorimeter designed by the <a href="https://www.uib.no/en/ift/142356/medical-physics-bergen-pct-project">Bergen pCT collaboration</a> for proton computed tomography (Alme et al. 2020).</p> <ul> <li><strong>treatment_simulations.tar.gz:</strong> 36258 simulations with the 715-HN phantom</li> <li><strong>treatment_simulations_vhf.tar.gz:</strong> 35673 simulations with the VHF phantom</li> </ul> <p>Each simulation is a single pencil beam with <span class="math-tex">\(10^7\)</span> primary protons. To determine valid spots to use, probing simulations with <span class="math-tex">\(10^5\)</span> primaries were conducted, where the beam position, energy, and phantom rotation were varied: 10 mm interval in the xy-plane for the beam position, 3 mm water range interval for the beam energy, and 30° rotations of the phantom. If no primary was found in the detecter after the probing simulation, it is a valid spot for the dataset.</p> <p>Resulting hit files, containing simulated detector readout, can be found in the archive files for the respective phantom. Each simulation is accompanied by a metafile in JSON format, specifying all parameters used to produce the output. E.g., beam position and energy can be found in "parameters" -> "beam_spot_x", "beam_spot_y", "beam_energy" and the phantom rotation can be found in "parameters" -> "phantom_rotation_angle".</p> <p>Simulation data has been pre-processed with two steps. First, hits for the same track in the same layer are binned together into a single entry by averaging the positions (posX, posY, posZ) and summing the energy depositions (edep). Second, the energy deposition values are discretized into a cluster size and back into MeV, to represent the energy resolution of the ALPIDE chip (Alme et al. 2020). Clusters of size 0 are removed. Additionally, some of the unused GATE output columns are removed and a column specifying the detector layer is created through the formula layer = 2*volumeID[2] + volumeID[3]. Details about the meaning of the other output columns can be found in the <a href="https://opengate.readthedocs.io/en/latest/data_output_management.html">GATE documentation</a>.</p>
ShareScore
44/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 8
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 4
Topics
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.