Tailoring Ti Grade 2 and TNTZ alloy surfaces in a two-step mechanical-chemical modification
<p>This record contains all files generated in the preparation process of the following publication:</p> <p>Agnieszka Kowalczyk, Donata Kuczyńska-Zemła, Agata Sotniczuk, Klaudia Anuszewska and Halina Garbacz,<br> "Tailoring Ti Grade 2 and TNTZ alloy surfaces in a two-step mechanical-chemical modification", submitted to Surface Engineering.</p> <p><br> Designations:<br> Ti alloy - Ti-29Nb-13Ta-4,6Zr alloy (TNTZ)<br> G - sample grinded on #600 grit abrasive paper<br> S_1,2 - sample shot peened with 90-150 µm shots, under pressure of 0.2 MPa<br> S_1,3 - sample shot peened with 90-150 µm shots, under pressure of 0.3 MPa<br> S_1,4 - sample shot peened with 90-150 µm shots, under pressure of 0.4 MPa<br> S_1,5 - sample shot peened with 90-150 µm shots, under pressure of 0.5 MPa<br> S_2,4 - sample shot peened with 150-250 µm shots, under pressure of 0.4 MPa<br> S_2,5 - sample shot peened with 150-250 µm shots, under pressure of 0.5 MPa<br> SE_1,2 - sample shot peened with 90-150 µm shots, under pressure of 0.2 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> SE_1,3 - sample shot peened with 90-150 µm shots, under pressure of 0.3 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> SE_1,4 - sample shot peened with 90-150 µm shots, under pressure of 0.4 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> SE_1,5 - sample shot peened with 90-150 µm shots, under pressure of 0.5 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> SE_2,4 - sample shot peened with 150-250 µm shots, under pressure of 0.4 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> SE_2,5 - sample shot peened with 150-250 µm shots, under pressure of 0.5 MPa and etched in a solution of 3% hydrofluoric acid (HF)<br> HV - Vickers hardness<br> SEM - Scanning Electron Microscopy<br> R - roughness<br> W - wettability</p> <p><br> Folders content:<br> Hardness - contains files with data obtained from hardness tests using a Falcon 500 hardness tester with a Vickers indenter at a load of 1.96 N (HV0.2)<br> Roughness - contains files from topography analysis obtained using a Wyko NT9300 optical profilometer for various scan areas<br> SEM - contains images of samples surfaces from Hitachi SU8000 and Hitachi SU70 Scanning Electron Microscopes <br> Wettability - contains files with data obtained from wettability tests using a DataPhysics OCA 25 goniometer with the sessile drop method</p> <p>This research was funded in part by National Science Centre, Poland [Grant no. 2022/45/B/ST5/03398].</p> <p> </p>
ShareScore
36/100
Overall dataset sharing score
Score breakdown
These five areas show where the dataset supports — or may limit — practical reuse.
- Stewardship
- 8
- Harmonization
- 4
- Access
- 16
- Reuse readiness
- 8
- Engagement
- 0
Topics
ScienceDex for faculty
Your academic CV and NIH biosketch
Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.