Skip to main content
zenodoopen

Preservation of corneous beta proteins in Mesozoic feathers

<p><strong>S-XANES data. </strong>Small samples (&ge;3 mm<sup>2</sup>) of untreated and experimentally degraded feathers in addition to fossil material and samples of host sediment were placed on low-sulfur mylar tape and analyzed at the Stanford Synchrotron Radiation Lightsource (SSRL) using synchrotron X-ray absorption near-edge spectroscopy (XANES) at beam line 6-2. S-XANES data were collected in fluorescence mode using a single element Vortex silicon drift detector set at an angle of ~90&deg; to the incident beam to minimize the scatter signal. The incident x-ray energy was selected using a Si(111) monochromator, which was calibrated using a Na<sub>2</sub>S<sub>2</sub>O<sub>3 </sub>standard with the thiol pre-edge peak defined as 2472.02 eV. S-XANES standards for selected S-bearing compounds, representing different S species, were prepared by mixing commercially available analytical standards (Sigma Aldrich; &ge;98% pure) with BN to obtain a S concentration of ca. 5 wt% in each standard. Data alignment, averaging, background subtraction and normalisation were performed using Athena v. 0.9.26.</p> <p>&nbsp;</p> <p><strong>FTIR data.</strong>&nbsp;Fossil data were collected in the 4000&ndash;600 cm<sup>-1</sup> range using a PerkinElmer Frontier FTIR spectrometer fitted with a Spotlight 400 microscope. Each spectrum was collected as an average of 8&ndash;36 scans. Spectra for untreated and matured feathers were collected in the 4000&ndash;500 cm<sup>-1</sup> range using a universal diamond ATR accessory on the Frontier spectrometer. Each spectrum was collected as an average of 10 scans. Each spectrum was baseline-corrected using SpectraGryph v. 1.2.7 using the parameters adaptive correction, 15% coarseness and no offset. In addition, interactive baseline correction was performed on data in the region 898&ndash;450 cm<sup>-1</sup> using Spectrum IR v. 10.6.1 (PerkinElmer, USA). This ensured a consistent baseline across the entire scan range to facilitate spectral comparison. Each spectrum was standardized to remove sample thickness effects.</p>

ShareScore

32/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
16
Reuse readiness
0
Engagement
4

Topics

Dataset details

Repository
zenodo
Published
September 20, 2023
License
cc-by-4.0
DOI
10.5281/zenodo.8161215

Scored with release 0.9.0

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.