Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
2,077
datasets available to search
ShareScore release 0.9.0
Dataset results
2,077 results for “Endoscope”
Study Evaluating the Safety and Feasibility of Endoscopic Duodenal Injections of Autologous Mesenchymal Stem Cells
ClinicalTrials.gov study NCT07344324. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Clinical Study of Double-Endoscopic Combined With Minimally Invasive Treatment for Early Gastric Cancer at Clinical Stage T1b
ClinicalTrials.gov study NCT06934824. IPD Sharing: UNDECIDED. Countries: 0. Publications: 0.
Perioperative Outcome of Corticosteroids in Transforaminal Endoscopic Lumbar Discectomy
ClinicalTrials.gov study NCT03273036. IPD Sharing: NO. Countries: 0. Publications: 0.
Comparison of Clinical Effect Between Endoscopic and Microscopic Ear Surgery of Cholesteatoma: A Multicenter Retrospective Observational Study
ClinicalTrials.gov study NCT05182268. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Comparison of Secretin-enhanced Magnetic Resonance Cholangiopancreatography (S-MRCP) to Endoscopic Pancreatic Function Test (ePFT) in Diagnosing Pancreatic Exocrine Insufficiency
ClinicalTrials.gov study NCT01094600. IPD Sharing: Not stated. Countries: 0. Publications: 0.
To Determine the Efficacy of the TwinGuard in Oxygen Delivery During and Post Endoscopic Procedure
ClinicalTrials.gov study NCT00619606. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Frequency and Causes of Failed Endoscopic Retrograde Cholangio-Pancreatography in AL-Rajhi Endoscopy Unit
ClinicalTrials.gov study NCT04818567. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Endoscopic Resection of Papillary Adenomas; a Novel Treatment Algorithm to Prevent Recurrence - a Pilot-study
ClinicalTrials.gov study NCT06216730. IPD Sharing: NO. Countries: 0. Publications: 0.
Transvaginal Cholecystectomy Using Endoscopic Assistance
ClinicalTrials.gov study NCT00815438. IPD Sharing: NO. Countries: 0. Publications: 0.
Effectivity of Bispectral Index Monitoring in Cases of Endoscopic Retrograde Cholangiopancreatography
ClinicalTrials.gov study NCT03114774. IPD Sharing: Not stated. Countries: 0. Publications: 0.
TRANSCRIPTOMIC ANALYSIS ON ENDOSCOPIC ULTRASOUND FINE NEEDLE ASPIRATION MATERIALS FROM PRIMARY PANCREATIC ADENOCARCINOMA
GEO Series GSE253260. Homo sapiens. 397 samples. Type: Expression profiling by high throughput sequencing.
Dataset related to article "Pancreatic Neuroendocrine Tumours: The Role of Endoscopic Ultrasound Biopsy in Diagnosis and Grading Based on the WHO 2017 Classification."
<p>One of the controversial issues in the diagnosis of pancreatic neuroendocrine tumours (pNETs) is the accurate prediction of their clinical behaviour.</p> <p>OBJECTIVES:</p> <p>The aim of the study was to evaluate the role of endoscopic ultrasound (EUS) biopsy in the diagnosis and grading of pNETs in a certified ENETS Center.</p> <p>METHODS:</p> <p>A prospectively maintained database of EUS biopsy procedures was retrospectively reviewed to identify all consecutive patients referred to a certified ENETS Center with a suspicion of pNET between June 2014 and April 2017. The cytological and/or histological specimens were stained and the Ki-67 labeling index was evaluated. In patients undergoing surgery, the grade obtained with EUS-guided biopsy was compared with the final histological grade. The grade was evaluated according to the 2017 WHO classifications and grading.</p> <p>RESULTS:</p> <p>The study population included 59 patients. EUS biopsy material reached an adequacy of 98.3% and was adequate for Ki-67 evaluation in 84.7% of cases. Twenty-nine patients (49.2%) underwent surgery. Of these, 25 patients had Ki-67 evaluated on EUS biopsy: the agreement between EUS biopsy grading and surgical specimen grading was 84%.</p> <p>CONCLUSION:</p> <p>EUS biopsy is an accurate method for the diagnosis and grading of pNETs based on the WHO 2017 Ki-67 labelling scheme.</p>
Dataset related to article "Outcomes of Non-Mucosa Sparing Endoscopic Sinus Surgery (Partial Reboot) in Refractory Chronic Rhinosinusitis with Nasal Polyposis: An Academic Hospital Experience "
<p>This record contains raw data related to article “Outcomes of Non-Mucosa Sparing Endoscopic Sinus Surgery (Partial Reboot) in Refractory Chronic Rhinosinusitis with Nasal Polyposis: An Academic Hospital Experience"</p> <p><strong>Objective: </strong> The reboot approach could be an effective treatment option to lower recurrence rates (RRs) in recalcitrant Chronic Rhinosinusitis with Nasal Polyps (CRSwNP). The purpose of this study was to investigate RR, recurrence-free survival (RFS), quality of life (QoL) improvement, and oral corticosteroid (OCS) intake in pluri-operated CRSwNP patients treated with partial reboot surgery.</p> <p><strong>Methods: </strong> A consecutive sample of patients with recalcitrant CRSwNP, ineligible for monoclonal antibodies, underwent partial reboot surgery. The 22-item SinoNasal Outcome Test (SNOT-22), Visual Analogue Scales (VAS) scores, OCS intake, and endoscopic Nasal Polyp Score (NPS) were collected pre and postoperatively. The main outcomes were RR and RFS, and comparison of disease-free time with previous endoscopic surgeries.</p> <p><strong>Results: </strong> Thirty pluri-operated patients were enrolled. Before the reboot, all had experienced disease recurrence at a mean recurrence time of 8.08 ± 2.83 months after surgery. After reboot, 7 (23.3%) had recurrence at a mean time of 16.67 ± 3.07 months (p = 0.02); none needed additional revision surgery till time of data collection. RR at 12, 18, and 24 months follow-up resulted significantly lower for reboot than other previous surgeries (p = 0.010, p = 0.002, p = 0.016, respectively); RFS difference resulted significant (log-rank test = 4.16; p = 0.04). Differences between pre-and post-operative total and single-items scores of SNOT-22 were significant (p = 0.001), as well as VAS scores (p = 0.001). Before the reboot, 21 patients (70%) took ≥2 OCS courses per year; at the latest follow-up visit, none had taken any course of OCS after reboot.</p> <p><strong>Conclusions: </strong> The reboot approach showed lower RR, longer RFS, improved QoL, and zeroing of OCS uptake. Larger samples and longer follow-up studies are needed to assess long-term efficacy and safety of this procedure.</p> <p><strong>Level of evidence: </strong> Level 4. According to the Oxford Center for Evidence-Based Medicine 2011 level of evidence guidelines, this non-randomized retrospective cohort study is classified as level 4 evidence Laryngoscope, 2022. Laryngoscope, 2022.</p> <p> </p>
RNA sequencing of endoscopic biopsies from patients with esophageal adenocarcinoma
GEO Series GSE207527. Homo sapiens. 200 samples. Type: Expression profiling by high throughput sequencing.
Dataset related to article "Endoscopic ultrasound-guided fine-needle biopsy with or without macroscopic on-site evaluation: a randomized controlled noninferiority trial "
<p>This record contains raw data related to article “Endoscopic ultrasound-guided fine-needle biopsy with or without macroscopic on-site evaluation: a randomized controlled noninferiority trial"</p> <p>Abstract</p> <p>BACKGROUND : The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. METHODS : This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. RESULTS : 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %-93.9 %] vs. 87.8 % [95 %CI 82.1 %-92.2 %]; <em>P</em> = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %-96.3 %] vs. 95.5 % [95 %CI 91.4 %-98 %]; <em>P</em> = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; <em>P</em> = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; <em>P</em> < 0.001). CONCLUSIONS : The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.</p>
Dataset related to article "Endoscopic suturing for GI applications: initial results from a prospective multicenter European registry "
<p>This record contains raw data related to article “Endoscopic suturing for GI applications: initial results from a prospective multicenter European registry"</p> <p>Abstract</p> <p><strong>Background and aims: </strong> OverStitch devices (OverStitch and OverStitch Sx; Apollo Endosurgery, Inc, Austin, Tex, USA) are used for a wide range of applications. A European registry was created to prospectively collect technical and clinical data regarding both systems to provide procedural outcomes and to find correlation between procedural characteristics and outcomes. This study shows the initial results of the first 3 years of the registry.</p> <p><strong>Methods: </strong> Patients who underwent endoscopic suturing from January 2018 to January 2021 at 9 centers were enrolled. Data regarding the disease treated,suturing pattern and outcomes were registered. Technical feasibility (success reaching the target area), technical success (success placing sutures), and clinical success (complete resolution of the clinical issue) were recorded and analyzed.</p> <p><strong>Results: </strong> During the study period, 137 patients (57.7% men) were enrolled with 100% technical feasibility rate. Endoscopic suturing was successfully performed in 136 cases (16.7% with OverStitch Sx), obtaining a technical success rate of 99.3%. No adverse events were recorded. Overall clinical success was 89%. Mucosal defects were sutured in 32 patients (100% clinical success). Leaks/fistulas were treated in 23 patients (64.7% clinical success). The clinical success of stent fixations (n = 38) was 85%. Perforations (n = 22) were repaired with a clinical success of 94.7%. No significant correlation between location, suture pattern or number, and the success was found, except in case of fistulas where fistulas <1 cm treated by a continuous suture were more likely to achieve clinical success in the follow-up (P < .001).</p> <p><strong>Conclusions: </strong> OverStitch-based suturing is technically feasible regardless of site and method of suturing, with no cases of failure. The overall technical success rate of 99.3% and the clinical outcome success rate of 89% demonstrate that OverStitch technology provides reliable suturing with clinical advantages, especially with fistulas <1 cm.</p>
Video showing the endoscopic transgastric hepatic cyst deroofing (ETGHCD) procedure.
<p><strong>V</strong><strong>ideo 1</strong>. Video showing the endoscopic transgastric hepatic cyst deroofing (ETGHCD) procedure.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.