Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
306
datasets available to search
ShareScore release 0.9.0
Dataset results
306 results for “MMS”
MMS 1 Energetic Particle Detector, Energetic Ion Spectrometer (EPD-EIS) Energy by Time of Flight, Level 2 (L2), Survey Mode, 2.42 s Data
Energetic Particle Detector (EPD), Energetic Ion Spectrometer (EIS) Energy by Time of Flight, Level 2, Quick-Look Survey, 2.42 s Data. The EIS provides ion composition measurements (protons versus oxygen ions) and angular distributions over the energy range from approximately 45 to 500 keV.
MMS 4 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Distribution Moments, Level 2 (L2), Burst Mode, 30 ms Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually Operates in Slow Survey (SS) Mode outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Results from integrating the standard Moments of Phase Space Distributions formed from the indicated Data Type (DES/DIS Burst, FS or SS). For Convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 4 Fast Plasma Investigation, Dual Ion Spectrometer (FPI, DIS) Partial Distribution Moments, Level 2 (L2), Burst Mode, 0.15 s Data
FPI usually operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually operates in Slow Survey (SS) Mode (60 s Resolution) outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Partial Moments that come from performing the Standard Moment Integrals over a limited Portion of Velocity Space. The resulting Quantities are named similarly to their corresponding Standard Moments, but are decorated with 'part' to differentiate. For example, density_part is the Density Moment integrated from a particular Energy Step to Infinity. These Partial Moments are formed from the indicated Data Type (DES/DIS Burst, FS or SS). For convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 2 Electron Drift Instrument (EDI) Ambient Electron Flux, Projection Method 2 (PM2), Level 2 (L2), Burst Mode, 0.9765625 ms Data
Electron Drift Instrument (EDI) Ambient Burst Survey, Level 2, 0.0009765625 s Data (1024 samples/s). EDI has two scientific data acquisition modes, called electric field mode and ambient mode. In electric field mode, two coded electron beams are emitted such that they return to the detectors after one or more gyrations in the ambient magnetic and electric field. The firing directions and times-of-flight allow the derivation of the drift velocity and electric field. In ambient mode, the electron beams are not used. The detectors with their large geometric factors and their ability to adjust the field of view quickly allow continuous sampling of ambient electrons at a selected pitch angle and fixed but selectable energy. To find the beam directions that will hit the detector, EDI sweeps each beam in the plane perpendicular to B at a fixed angular rate of 0.22 °/ms until a signal has been acquired by the detector. Once signal has been acquired, the beams are swept back and forth to stay on target. Beam detection is not determined from the changes in the count-rates directly, but from the square of the beam counts divided by the background counts from ambient electrons, i.e., from the square of the instantaneous signal-to-noise ratio (SNR). This quantity is computed from data provided by the correlator in the Gun-Detector Electronics that also generates the coding pattern imposed on the outgoing beams. If the squared SNR ratio exceeds a threshold, this is taken as evidence that the beam is returning to the detector. The thresholds for SNR are chosen dependent on background fluxes. They represent a compromise between getting false hits (induced by strong variations in background electron fluxes) and missing true beam hits. The basic software loop that controls EDI operations is executed every 2 ms. As the times when the beams hit their detectors are neither synchronized with the telemetry nor equidistant, EDI data have no fixed time-resolution. Data are reported in telemetry slots. In Survey, using the standard packing mode 0, there are eight telemetry slots per second and Gyn Detector Unit (GDU). The last beam detected during the previous slot will be reported in the current slot. If no beam has been detected, the data quality will be set to zero. In Burst telemetry there are 128 slots per second and GDU. The data in each slot consists of information regarding the beam firing directions (stored in the form of analytic gun deflection voltages), times-of-flight (if successfully measured), quality indicators, time stamps of the beam hits, and some auxiliary correlator-related information. Whenever EDI is not in electron drift mode, it uses its ambient electron mode. The mode has the capability to sample at either 90 degrees pitch angle or at 0/180 degrees (field aligned), or to alternate between 90 degrees and field aligned with selectable dwell times. While all options have been demonstrated during the commissioning phase, only the field aligned mode has been used in the routine operations phase. The choices for energy are 250 eV, 500 eV, and 1 keV. The two detectors, which are facing opposite hemispheres, are looking strictly into opposite directions, so while one detector is looking along B the other is looking antiparallel to B (corresponding to pitch angles of 180 and 0 degrees, respectively). The two detectors switch roles every half spin of the spacecraft as the tip of the magnetic field vector spins outside the field of view of one detector and into the field of view of the other detector. Starting January 4, 2016, the anodes were chosen such that the projection of the magnetic field vector was best aligned with the center of the first (that is, outer) of the four anodes. This provides coverage of a larger range of pitch angles in general. Data taken in this configuration are identified by the term "amb-pm2" in the data product names. In the burst data where four channels (corresponding to the four adjacent sensor anode pads) are sampled per GDU, channel 1 represents best the pitch angle of 0 degrees (or 180 degrees). The EDI instrument paper can be found at: http://link.springer.com/article/10.1007%2Fs11214-015-0182-7. The EDI instrument data products guide can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 2 Energetic Particle Detector, Energetic Ion Spectrometer (EPD-EIS) Electron Energy Spectra, Level 2 (L2), Survey Mode, 2.42 s Data
Energetic Particle Detector (EPD), Energetic Ion Spectrometer (EIS) Electron Energy Spectra, Level 2, Quick-Look Survey, 2.42 s Data. The EIS provides ion composition measurements (protons versus oxygen ions) and angular distributions over the energy range from approximately 45 to 500 keV.
MMS 4 Magnetic Ephemeris and Coordinates (MEC) and Support (Tsyganenko 2004 model, Dynamic conditions), Level 2 (L2), Survey Mode, 30 s Data
Magnetospheric Multiscale 4 (MMS 4) spacecraft position, velocity, attitude, angular momentum vector, and magnetic ephemeris and coordinates (MEC), Level-2 science data at Quick-Look (30 s) time resolution. The Magnetic ephemeris data are calculated by using the Tsyganenko 2004 magnetic field model for disturbed magnetospheric conditions. Many variables are included in this data product including the magnetic field measured at the spacecraft. If possible, the northern and southern hemisphere footpoints of the spacecraft are found by tracing along the magnetic field line threading through the spacecraft per the given Tsyganenko and internal magnetic field models. The northern and southern hemisphere loss cone angles are also given. The magnetic field strength at the footpoints and the minimum magnetic field strength along the field line are also calculated by using the field models. Other variables list the spacecraft L-shell, the magnetic local time, the magnetic latitude and longitude, and whether the threading field line is open, closed, etc. Rotational quaternions are provided to allow coordinate transformation from GEI into 6 other coordinate systems including BSC, GEO, GSE, GSE2000, GSE, and SM. The list of ancillary variables includes the dipole tilt angle, the Dst and Kp actvity indices, and separate flags that denote satellite eclipse by the Earth and Moon.
MMS 4 Electron Drift Instrument (EDI) Quality Zero Counts, Level 2 (L2), Survey Mode, 0.125 s Data
Electron Drift Instrument (EDI) Q0 Survey, Level 2, 0.125 s Data (8 samples/s). EDI has two scientific data acquisition modes, called electric field mode and ambient mode. In electric field mode, two coded electron beams are emitted such that they return to the detectors after one or more gyrations in the ambient magnetic and electric field. The firing directions and times-of-flight allow the derivation of the drift velocity and electric field. In ambient mode, the electron beams are not used. The detectors with their large geometric factors and their ability to adjust the field of view quickly allow continuous sampling of ambient electrons at a selected pitch angle and fixed but selectable energy. To find the beam directions that will hit the detector, EDI sweeps each beam in the plane perpendicular to B at a fixed angular rate of 0.22 °/ms until a signal has been acquired by the detector. Once signal has been acquired, the beams are swept back and forth to stay on target. Beam detection is not determined from the changes in the count-rates directly, but from the square of the beam counts divided by the background counts from ambient electrons, i.e., from the square of the instantaneous signal-to-noise ratio (SNR). This quantity is computed from data provided by the correlator in the Gun-Detector Electronics that also generates the coding pattern imposed on the outgoing beams. If the squared SNR ratio exceeds a threshold, this is taken as evidence that the beam is returning to the detector. The thresholds for SNR are chosen dependent on background fluxes. They represent a compromise between getting false hits (induced by strong variations in background electron fluxes) and missing true beam hits. The basic software loop that controls EDI operations is executed every 2 ms. As the times when the beams hit their detectors are neither synchronized with the telemetry nor equidistant, EDI data have no fixed time-resolution. Data are reported in telemetry slots. In Survey, using the standard packing mode 0, there are eight telemetry slots per second and Gyn Detector Unit (GDU). The last beam detected during the previous slot will be reported in the current slot. If no beam has been detected, the data quality will be set to zero. In Burst telemetry there are 128 slots per second and GDU. The data in each slot consists of information regarding the beam firing directions (stored in the form of analytic gun deflection voltages), times-of-flight (if successfully measured), quality indicators, time stamps of the beam hits, and some auxiliary correlator-related information. Whenever EDI is not in electron drift mode, it uses its ambient electron mode. The mode has the capability to sample at either 90 degrees pitch angle or at 0/180 degrees (field aligned), or to alternate between 90 degrees and field aligned with selectable dwell times. While all options have been demonstrated during the commissioning phase, only the field aligned mode has been used in the routine operations phase. The choices for energy are 250 eV, 500 eV, and 1 keV. The two detectors, which are facing opposite hemispheres, are looking strictly into opposite directions, so while one detector is looking along B the other is looking antiparallel to B (corresponding to pitch angles of 180 and 0 degrees, respectively). The two detectors switch roles every half spin of the spacecraft as the tip of the magnetic field vector spins outside the field of view of one detector and into the field of view of the other detector. These data are a by-product generated from data collected in electric field mode. Whenever no return beam is found in a particular time slot by the flight software to be reported will be flagged with the lowest quality level (quality zero). The ground processing generates a separate data product from these counts data. The EDI instrument paper can be found at: http://link.springer.com/article/10.1007%2Fs11214-015-0182-7. The EDI instrument data products guide can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 3 Magnetic Ephemeris and Coordinates (MEC) and Support (Tsyganenko 1989 model, Quiet conditions), Level 2 (L2), Survey Mode, 30 s Data
Magnetospheric Multiscale 3 (MMS 3) spacecraft position, velocity, attitude, angular momentum vector, and magnetic ephemeris and coordinates (MEC), Level-2 science data at Quick-Look (30 s) time resolution. The Magnetic ephemeris data are calculated by using the Tsyganenko 1989 magnetic field model for quiet magnetospheric conditions. Many variables are included in this data product including the magnetic field measured at the spacecraft. If possible, the northern and southern hemisphere footpoints of the spacecraft are found by tracing along the magnetic field line threading through the spacecraft per the given Tsyganenko and internal magnetic field models. The northern and southern hemisphere loss cone angles are also given. The magnetic field strength at the footpoints and the minimum magnetic field strength along the field line are also calculated by using the field models. Other variables list the spacecraft L-shell, the magnetic local time, the magnetic latitude and longitude, and whether the threading field line is open, closed, etc. Rotational quaternions are provided to allow coordinate transformation from GEI into 6 other coordinate systems including BSC, GEO, GSE, GSE2000, GSE, and SM. The list of ancillary variables includes the dipole tilt angle, the Dst and Kp actvity indices, and separate flags that denote satellite eclipse by the Earth and Moon.
MMS 3 Fast Plasma Investigation, Dual Ion Spectrometer (FPI, DIS) Distribution Moments, Level 2 (L2), Fast Mode, 4.5 s Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution are aggregated onboard and made available at Survey (4.5 s) Resolution in this Mode. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually Operates in Slow Survey (SS) Mode outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Results from integrating the standard Moments of Phase Space Distributions formed from the indicated Data Type (DES/DIS Burst, FS or SS). For Convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 4 Hot Plasma Composition Analyzer (HPCA) Ions, Level 2 (L2), Survey Mode, 0.625 s Data
Hot Plasma Composition Analyzer (HPCA) Ions, Level 2, Survey, 0.625 s Data. The MMS HPCA instruments measure the energy and composition of magnetospheric plasmas in the energy range from 1 eV to 40 keV. An electrostatic energy analyzer (ESA) that is optically coupled to a carbon-foil based Time-of-Flight (TOF) section comprises each HPCA. The basic HPCA data product is an array of counts for 5 ion species, at 63 energies, for each of 16 elevation anodes. Sixteen basic products, also called azimuths, are acquired every 0.625 s; half a spacecraft spin period nominally has 16 azimuths. The five ion species are protons (H+), alpha particles (He++), helium ions (He+), singly charged Oxygen (O+), and background counts.
MMS 1 Search Coil Magnetometer (SCM) AC Magnetic Field Level 2 (L2), Burst Mode, 8192 Sample/s Data
Search Coil Magnetometer (SCM) AC Magnetic Field (8192 samples/s), Level 2, Burst Mode Data. The tri-axial Search-Coil Magnetometer with its associated preamplifier measures three-dimensional magnetic field fluctuations. The analog magnetic waveforms measured by the SCM are digitized and processed inside the Digital Signal Processor (DSP), collected and stored by the Central Instrument Data Processor (CIDP) via the Fields Central Electronics Box (CEB). Prior to launch, all SCM Flight models were calibrated by LPP team members at the National Magnetic Observatory, Chambon-la-Foret (Orleans). Once per orbit, each SCM transfer function is checked thanks to the onboard calibration signal provided by the DSP. The SCM is operated for the entire MMS orbit in survey mode. Within scientific Regions Of Interest (ROI), burst mode data are also acquired as well as high speed burst mode data. This SCM data set corresponds to the AC magnetic field waveforms in nanoTesla and in the GSE frame. The SCM instrument paper for SCM can be found at http://link.springer.com/article/10.1007/s11214-014-0096-9 and the SCM data product guide at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 2 Magnetic Ephemeris and Coordinates (MEC) and Support (Tsyganenko 1989 model, Quiet conditions), Level 2 (L2), Burst Mode, 30 ms Data
Magnetospheric Multiscale 2 (MMS 2) spacecraft position, velocity, attitude, angular momentum vector, and magnetic ephemeris and coordinates (MEC), Level-2 science data at Burst (30 ms) time resolution. The Magnetic ephemeris data are calculated by using the Tsyganenko 1989 magnetic field model for quiet magnetospheric conditions. Many variables are included in this data product including the magnetic field measured at the spacecraft. If possible, the northern and southern hemisphere footpoints of the spacecraft are found by tracing along the magnetic field line threading through the spacecraft per the given Tsyganenko and internal magnetic field models. The northern and southern hemisphere loss cone angles are also given. The magnetic field strength at the footpoints and the minimum magnetic field strength along the field line are also calculated by using the field models. Other variables list the spacecraft L-shell, the magnetic local time, the magnetic latitude and longitude, and whether the threading field line is open, closed, etc. Rotational quaternions are provided to allow coordinate transformation from GEI into 11 other coordinate systems including BSC, GEO, GSE, GSE2000, GSE, and SM. The list of ancillary variables includes the dipole tilt angle, the Dst and Kp actvity indices, and separate flags that denote satellite eclipse by the Earth and Moon.
MMS 3 Fast Plasma Investigation, Dual Ion Spectrometer (FPI, DIS) Partial Distribution Moments, Level 2 (L2), Burst Mode, 0.15 s Data
FPI usually operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually operates in Slow Survey (SS) Mode (60 s Resolution) outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Partial Moments that come from performing the Standard Moment Integrals over a limited Portion of Velocity Space. The resulting Quantities are named similarly to their corresponding Standard Moments, but are decorated with 'part' to differentiate. For example, density_part is the Density Moment integrated from a particular Energy Step to Infinity. These Partial Moments are formed from the indicated Data Type (DES/DIS Burst, FS or SS). For convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
3' RNA sequencing of the mouse cortex at P6 following MMS and/or LPS
GEO Series GSE157184. Mus musculus. 12 samples. Type: Expression profiling by high throughput sequencing.
MMS induced expression changes and the effect of sorafenib
GEO Series GSE57161. Homo sapiens. 16 samples. Type: Expression profiling by high throughput sequencing.
MMS induced expression changes
GEO Series GSE57801. Drosophila melanogaster; Mus musculus. 71 samples. Type: Expression profiling by array.
Low-level MMS treatment of S.cerevisiae
GEO Series GSE8237. Saccharomyces cerevisiae. 14 samples. Type: Expression profiling by array.
MMS 4 Electric Double Probe (EDP) Spacecraft Potential, Level 2 (L2), Fast Mode, 31.25 ms Data
Electric Double Probe, Dual Probe Spacecraft Potential, Level 2, Fast Survey Data. Spacecraft potential is etstimatrd by averaging measurements of the probe-to-spacecraft potential from several probes.
MMS 1 Digital Signal Processor (DSP) Search Coil Magnetometer (SCM), Magnetic Field Power Spectral Density, Level 2 (L2), Fast Mode, 2 s Data
The MMS magnetic field power spectral density (BPSD) is computed onboard by the Digital Signal Processor (DSP). The fast Fourier transform (FFT) calculation is performed on a digitized version of analog signals from the Search Coil Magnetometer (SCM) in the SCM123 coordinate system, see SCM data product guide for details, https://lasp.colorado.edu/mms/sdc/public/datasets/fields/. This data product is computed in space from individual components that are not synchronized to the 1 second pulse. Therefore, the timing between channels can be inaccurate by a fraction of a second. The samples times are interval start times taken from the x component. The spectra are calculated via a 1024-point FFT algorithm on piecewise continuous sets of waveform data. Nine signals can be processed simultaneously. Six of the twelve DC-coupled E, DC-coupled V, or SCM signals (16384 samples/s) are selected for spectral processing at 100% duty cycle. In addition, the three AC-coupled signals (262,144 kS/s) each can be processed at 6.25% duty cycle. Each of the nine signals has 16, 1024-point FFT operations every second; the field-programmable gate array (FPGA) performs 144 FFTs per second. The FFT is performed by an arithmetic logic unit (ALU), which is controlled by a state machine. Both are hard-coded into the FPGA. The operation starts by applying a 1024-point Hanning window onto a waveform. Next, an FFT is implemented. The FFT is broken into a series of "butterfly" operations performed by the ALU. The result has real and imaginary data. Power spectra are calculated by taking the sum of squares of real and imaginary values (the ALU includes a multiplier), which produces a power spectrum with 512 frequency bins. The frequency bins are then combined to give pseudo-logarithmic frequency spacing (del f)/f. The spectra are reduced to 88 frequency bins with (del f)/f between 6% and 12% when possible. Narrow-band emissions can be fit to an accuracy of (del f)/f ~3%, allowing for an accurate determination of plasma density. The spectra can be averaged in time. The fastest reporting rate of any signal is 16 spectra per second. Reporting rates can be as slow a one spectra every 16 s (averaging 256 spectra). The DSP and SCM instrument papers can be found at https://link.springer.com/article/10.1007/s11214-014-0115-x and https://link.springer.com/article/10.1007/s11214-014-0096-9, respectively. The DSP and SCM data product guides can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 1 Electric Double Probe (EDP) Spacecraft Potential, Level 2 (L2), Slow Mode, 0.125 s Data
Electric Double Probe, Dual Probe Spacecraft Potential, Level 2, Slow Survey Data. Spacecraft potential is etstimatrd by averaging measurements of the probe-to-spacecraft potential from several probes.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.