Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
2,712
datasets available to search
ShareScore release 0.9.0
Dataset results
2,712 results for “Fluid”
Neisseria meningitidis elicits a pro-inflammatory response involving IκBζ in a human blood-cerebrospinal fluid barrier model.
GEO Series GSE42870. Homo sapiens. 12 samples. Type: Expression profiling by array.
Differences in miRNA expression profiles of follicular fluid exosomes between Premature ovarian insufficiency and normal ovarian reserve
GEO Series GSE253684. Homo sapiens. 6 samples. Type: Non-coding RNA profiling by high throughput sequencing.
Genome-wide methylation analysis of cerebrospinal fluid circulating tumor DNA: a new biomarker for recurrent glioblastoma [MeDIP-Seq]
GEO Series GSE205513. Homo sapiens. 7 samples. Type: Methylation profiling by high throughput sequencing.
The amniotic fluid cell-free transcriptome in spontaneous preterm labor
GEO Series GSE166956. Homo sapiens. 38 samples. Type: Expression profiling by array.
High fluid shear stress induces Hippo/YAP pathway in articular cartilage superficial layer cells: a potential mechanistic link to 0steoarthritis
GEO Series GSE289374. Rattus norvegicus. 6 samples. Type: Expression profiling by high throughput sequencing.
Alanyl-glutamine in peritoneal dialysis fluids - a randomized controlled phase I/II trial
GEO Series GSE57070. Homo sapiens. 6 samples. Type: Expression profiling by array.
MicroRNA Expression Profiles in Follicular Fluid Exosomes of Women with Different Ovarian Reserve
GEO Series GSE238177. Homo sapiens. 16 samples. Type: Non-coding RNA profiling by high throughput sequencing.
Expression of inflammatory and structural matrix genes in synovial fluid following intra-articular administration of isoflupredone acetate to exercised horses
GEO Series GSE98410. Equus caballus. 18 samples. Type: Expression profiling by array.
miRNAs in follicular fluid
GEO Series GSE63737. Homo sapiens. 23 samples. Type: Non-coding RNA profiling by array.
Increased Reproducibility of Brain Organoids through Controlled Fluid Dynamics
GEO Series GSE306010. Homo sapiens. 2 samples. Type: Expression profiling by high throughput sequencing.
Transcriptome and proteome profiles of the diazotroph Nitrospirillum amazonense strain CBAmC in response to the sugarcane apoplast fluid
GEO Series GSE130321. Nitrospirillum amazonense. 6 samples. Type: Expression profiling by high throughput sequencing.
Mating and sperm-free seminal fluid changes the gene expression in the utero-vaginal junction of White Leghorn hens
GEO Series GSE83621. Gallus gallus. 12 samples. Type: Expression profiling by array.
RNA-Seq and expression microarray highlight different aspects of the fetal amniotic fluid transcriptome [RNA-Seq]
GEO Series GSE49890. Homo sapiens. 5 samples. Type: Expression profiling by high throughput sequencing.
Whole transcriptomic analysis of uterine fluid exosomes during fresh embryo transfer cycles [lncRNA-seq]
GEO Series GSE273312. Homo sapiens. 38 samples. Type: Non-coding RNA profiling by high throughput sequencing.
Data set and 3d model from Emendi M, Sturla F, Ghosh RP, Bianchi M, Piatti F, Pluchinotta FR, Giese D, Lombardi M, Redaelli A, Bluestein D. Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid-Structure Interaction Approach. Ann Biomed Eng. 2020 Aug 17. doi: 10.1007/s10439-020-02571-4. Epub ahead of print. PMID: 32804291.
<p>Data set and 3d model from Emendi M, Sturla F, Ghosh RP, Bianchi M, Piatti F, Pluchinotta FR, Giese D, Lombardi M, Redaelli A, Bluestein D. Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid-Structure Interaction Approach. Ann Biomed Eng. 2020 Aug 17. doi: 10.1007/s10439-020-02571-4. Epub ahead of print. PMID: 32804291.</p> <p> </p> <p>This is the abstract:</p> <p>Congenital bicuspid aortic valve (BAV) consists of two fused cusps and represents a major risk factor for calcific valvular stenosis. Herein, a fully coupled fluid-structure interaction (FSI) BAV model was developed from patient-specific magnetic resonance imaging (MRI) and compared against in vivo 4-dimensional flow MRI (4D Flow). FSI simulation compared well with 4D Flow, confirming direction and magnitude of the flow jet impinging onto the aortic wall as well as location and extension of secondary flows and vortices developing at systole: the systolic flow jet originating from an elliptical 1.6 cm<sup>2</sup> orifice reached a peak velocity of 252.2 cm/s, 0.6% lower than 4D Flow, progressively impinging on the ascending aorta convexity. The FSI model predicted a peak flow rate of 22.4 L/min, 6.7% higher than 4D Flow, and provided BAV leaflets mechanical and flow-induced shear stresses, not directly attainable from MRI. At systole, the ventricular side of the non-fused leaflet revealed the highest wall shear stress (WSS) average magnitude, up to 14.6 Pa along the free margin, with WSS progressively decreasing towards the belly. During diastole, the aortic side of the fused leaflet exhibited the highest diastolic maximum principal stress, up to 322 kPa within the attachment region. Systematic comparison with ground-truth non-invasive MRI can improve the computational model ability to reproduce native BAV hemodynamics and biomechanical response more realistically, and shed light on their role in BAV patients' risk for developing complications; this approach may further contribute to the validation of advanced FSI simulations designed to assess BAV biomechanics.</p> <p> </p>
Design and Computational Fluid Dynamics (CFD) modelling of Biomimetic Voronoi lattice Scaffolds
Open the record for dataset details and reuse information.
datet related to article "The Pre-Lumbar puncture Intracranial Hypertension Scale (PLIHS): A practical scale to identify subjects with normal cerebrospinal fluid pressure in the management of idiopathic intracranial hypertension"
<p>The dataset contains the variables used to validata the PLIHS scale described in the manuscript.</p>
Computational Fluid Dynamics Modeling of Proximal Landing Zones for Thoracic Endovascular Aortic Repair in the Bovine Arch Variant.
<p>Dataset from the article Marrocco-Trischitta MM, Romarowski RM, Alaidroos M, Sturla F, Glauber M, Nano G. Computational Fluid Dynamics Modeling of Proximal Landing Zones for Thoracic Endovascular Aortic Repair in the Bovine Arch Variant. Ann Vasc Surg. 2020 Nov;69:413-417. doi: 10.1016/j.avsg.2020.05.024. Epub 2020 May 29. PMID: 32479874.</p> <p><strong>Abstract</strong></p> <p><strong>Background: </strong>To assess the endograft displacement forces (DF), which quantify the forces exerted by the pulsatile blood flow on the vessel wall and transmitted on the terminal fixation site of the endograft after its deployment in proximal landing zones (PLZs) of the bovine aortic arch variant.</p> <p><strong>Methods: </strong>Thirty healthy aortic computed tomographic angiographies of subjects with bovine arch configuration (10 per type of arch, I-III) were selected for the purpose of the study. A 3-dimensional model of the aortic arch lumen was reconstructed. Computational fluid dynamics modeling was then used to compute DF magnitude and orientation (i.e., x, y, and z axes) in PLZs of each case. DF values were normalized to the corresponding aortic wall area to estimate equivalent surface traction (EST).</p> <p><strong>Results: </strong>DF were highest in zone 0, consistently with the greater surface area. DF in zone 3 were much greater than in zone 2 because of a 3-fold greater upward component (z axis) (P < 0.001), being therefore mainly oriented orthogonally to the aortic blood flow and to the vessel longitudinal axis in that zone. EST progressively increased from zone 0 toward more distal PLZs, with EST in zone 3 being much greater than that in zone 2 (P < 0.001). The same pattern was observed after stratification by type of arch.</p> <p><strong>Conclusions: </strong>The bovine arch is associated with a consistent fluid dynamic pattern, which identifies in zone 3 an unfavorable biomechanical environment for endograft deployment.</p>
Comparison of Four-Dimensional Magnetic Resonance Imaging Analysis of Left Ventricular Fluid Dynamics and Energetics in Ischemic and Restrictive Cardiomyopathies.
<p>Riva A, Sturla F, Pica S, Camporeale A, Tondi L, Saitta S, Caimi A, Giese D, Palladini G, Milani P, Castelvecchio S, Menicanti L, Redaelli A, Lombardi M, Votta E. Comparison of Four-Dimensional Magnetic Resonance Imaging Analysis of Left Ventricular Fluid Dynamics and Energetics in Ischemic and Restrictive Cardiomyopathies. J Magn Reson Imaging. 2022 Oct;56(4):1157-1170. doi: 10.1002/jmri.28076. Epub 2022 Jan 24. PMID: 35075711; PMCID: PMC9541919.</p> <p>Abstract</p> <p><strong>Background: </strong>Time-resolved three-directional velocity-encoded (4D flow) magnetic resonance imaging (MRI) enables the quantification of left ventricular (LV) intracavitary fluid dynamics and energetics, providing mechanistic insight into LV dysfunctions. Before becoming a support to diagnosis and patient stratification, this analysis should prove capable of discriminating between clearly different LV derangements.</p> <p><strong>Purpose: </strong>To investigate the potential of 4D flow in identifying fluid dynamic and energetics derangements in ischemic and restrictive LV cardiomyopathies.</p> <p><strong>Study type: </strong>Prospective observational study.</p> <p><strong>Population: </strong>Ten patients with post-ischemic cardiomyopathy (ICM), 10 patients with cardiac light-chain cardiac amyloidosis (AL-CA), and 10 healthy controls were included.</p> <p><strong>Field strength/sequence: </strong>1.5 T/balanced steady-state free precession cine and 4D flow sequences.</p> <p><strong>Assessment: </strong>Flow was divided into four components: direct flow (DF), retained inflow, delayed ejection flow, and residual volume (RV). Demographics, LV morphology, flow components, global and regional energetics (volume-normalized kinetic energy [KE<sub>V</sub> ] and viscous energy loss [EL<sub>V</sub> ]), and pressure-derived hemodynamic force (HDF) were compared between the three groups.</p> <p><strong>Statistical tests: </strong>Intergroup differences in flow components were tested by one-way analysis of variance (ANOVA); differences in energetic variables and peak HDF were tested by two-way ANOVA. A P-value of <0.05 was considered significant.</p> <p><strong>Results: </strong>ICM patients exhibited the following statistically significant alterations vs. controls: reduced KE<sub>V</sub> , mostly in the basal region, in systole (-44%) and in diastole (-37%); altered flow components, with reduced DF (-33%) and increased RV (+26%); and reduced basal-apical HDF component on average by 63% at peak systole. AL-CA patients exhibited the following alterations vs. controls: significantly reduced KE<sub>V</sub> at the E-wave peak in the basal segment (-34%); albeit nonstatistically significant, increased peaks and altered time-course of the HDF basal-apical component in diastole and slightly reduced HDF components in systole.</p> <p><strong>Data conclusion: </strong>The analysis of multiple 4D flow-derived parameters highlighted fluid dynamic alterations associated with systolic and diastolic dysfunctions in ICM and AL-CA patients, respectively.</p>
Dataset related to article "Selective Cerebrospinal Fluid Hypothermia: Bioengineering Development and In Vivo Study of an Intraventricular Cooling Device (V‑COOL)"
<p><em>The database contains animal models MRI in DICOM and PNG file format.</em></p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.