Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

3,050

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

3,050 results for “ablation”

Learn how ShareScore rates datasets ↗
zenodo12/100

Dataset related to the article "Etiology and Outcome of Catheter Ablation in Patients With Onset of Atrial Fibrillation <45 Years of Age"

<p>This record contains raw data related to the article &quot;Etiology and Outcome of Catheter Ablation in Patients With Onset of Atrial Fibrillation &lt;45 Years of Age&quot;.</p> <p>&nbsp;</p> <p><em><strong>Abstract</strong></em></p> <p>Etiologic factors and long-term outcomes of catheter ablation of atrial fibrillation (AF) in young patients have not been well characterized. This study aimed to analyze the etiologic factors and outcomes of pulmonary vein isolation (PVI) in patients with young-onset AF (young-AF, defined as having first documented episode &lt;45 years). Consecutive patients with young-AF undergoing PVI (n = 197) in 2 academic centers were enrolled and followed for 36.1 &plusmn; 24.5 months. A control group of patients with AF onset &ge;45 years (n = 554) was included. The most frequent risk factors in young-AF were intensive exercise (25%), moderate-to-heavy alcohol consumption (23%), and familial AF (22%). Compared with patients with AF onset &ge;45-year, patients with young-AF were more often men (82% vs 66%, p &lt;0.001), had more frequently paroxysmal AF (81% vs 60%, p &lt;0.001), had less left atrial dilatation (40.9 &plusmn; 6.2 mm vs 44.2 &plusmn; 7.2 mm, p &lt;0.001), and had lower 4-year recurrence rate after last PVI procedure (22% vs 45%, p &lt;0.001). In young-AF, structural heart disease (SHD) was the only independent predictor of recurrence. Patients with young-AF selected to undergo cryoballoon (CB) ablation were younger (35.0 &plusmn; 7.7 vs 36.6 &plusmn; 6.7 years, p = 0.035) and had less persistent AF (6% vs 24%, p = 0.004) and coronary artery disease (2% vs 7%, p = 0.02) compared with radiofrequency ablation. After excluding patients with persistent AF and SHD, there was no difference in single procedural success between radiofrequency or CB PVI (27% vs 17%, p = 0.11). In conclusion, patients with young-AF have diverse etiologies and high single and multiprocedural PVI successes. SHD is the only independent predictor of recurrence. In patients with young-AF, there is a selection bias for CB ablation.</p>

restrictedMar 2022View details →
zenodo12/100

Dataset related to the article "Long-Term Outcomes of Near-Zero Radiation Ablation of Paroxysmal Supraventricular Tachycardia: A Comparison With Fluoroscopy-Guided Approach"

<p>This record contains raw data related to the article &quot;Long-Term Outcomes of Near-Zero Radiation Ablation of Paroxysmal Supraventricular Tachycardia: A Comparison With Fluoroscopy-Guided Approach&quot;.</p> <p>&nbsp;</p> <p><em><strong>Abstract</strong></em></p> <p><strong>Objectives:&nbsp;</strong>This study aimed to assess the long-term outcomes of minimally fluoroscopic approach (MFA) compared with conventional fluoroscopic ablation (ConvA) in terms of recurrences of arrhythmia and long-term complications.</p> <p><strong>Background:&nbsp;</strong>Catheter ablation (CA) of supraventricular tachycardia (SVT) with an MFA, under the guidance of electroanatomic mapping (EAM) systems, results in a significant reduction in exposure to ionizing radiations without impairing acute procedural success and complication rate. However, data regarding long-term outcomes of MFA compared with ConvA are lacking.</p> <p><strong>Methods:&nbsp;</strong>This is a retrospective observational study. All patients undergoing MFA CA of SVT (atrioventricular nodal re-entrant tachycardia and atrioventricular re-entrant tachycardia) between 2010 and 2015 were enrolled and were compared with matched subjects (1 MFA: 2 ConvA) undergoing ConvA during the same period. The 2 co-primary outcomes were recurrence of arrhythmias and long-term complications.</p> <p><strong>Results:&nbsp;</strong>A total of 618 patients (mean age 38 &plusmn; 15 years, 60% female) were enrolled. MFA included 206 patients, whereas 412 were treated with ConvA. Acute success (99% vs. 97%; p = 0.10) and acute complications (2.4% vs. 5.3%; p = 0.14) were similar in the 2 groups. During a median follow-up of 4.4 years, 5.9% of patients experienced recurrence of arrhythmias. At multivariate analysis, ConvA (hazard ratio [HR]: 3.03) and procedural success (HR: 0.10) were independently associated with recurrence of arrhythmias. Late complications (i.e., advance atrioventricular block and need for pacemaker implantation) occurred more frequently in ConvA (3.4% vs. 0.5%; p = 0.03) compared with MFA.</p> <p><strong>Conclusions:&nbsp;</strong>CA guided by EAM systems with MFA provided better long-term results and reduced risk of complications compared with ConvA.</p>

restrictedMar 2022View details →
zenodo12/100

Dataset related to the article "Cryoballoon atrial fibrillation ablation: Single-center safety and efficacy data using a novel cryoballoon technology compared to a historical balloon platform".

<p>This record contains raw data related to the article &quot;Cryoballoon atrial fibrillation ablation: Single-center safety and efficacy data using a novel cryoballoon technology compared to a historical balloon platform&quot;.</p> <p>&nbsp;</p> <p><em><strong>Abstract</strong></em></p> <p><strong>Introduction:&nbsp;</strong>Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx&trade; is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report.</p> <p><strong>Methods:&nbsp;</strong>To compare the POLARx&trade; cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO&trade; (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx&trade; were enrolled. Data were prospectively gathered. POLARx&trade; patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP.</p> <p><strong>Results:&nbsp;</strong>Seventy patients were analyzed, 20 in POLARx&trade;, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA<sub>2</sub>&nbsp;DS<sub>2</sub>&nbsp;-VASc 1, left-atrium size 34 ml/m&sup2;, and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx&trade; vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx&trade; group (90 min vs. 60 min, p &lt; .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx&trade; and AFAP groups, respectively. Despite equal TTI, the POLARx&trade; had a lower minimal temperature reached (-57&deg;C vs -47&deg;C, p &lt; .001).</p> <p><strong>Conclusion:&nbsp;</strong>The novel POLARx&trade; cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.</p>

restrictedMar 2022View details →
zenodo12/100

Ventricular PFA ablation in rat model -Lesion size data analysis

<p>Excel file with the data used for PFA ablation lesion size calculation corresponding to manuscript &quot;Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency&quot;.</p> <p>The data was extracted after analysis with QuPath software for the different conditions studied.</p>

restrictedJul 2023View details →
geo12/100

Med12 ablation promotes anti-tumor function by enhancing tumor intrinsic immunogenicity in Pancreatic ductal adenocarcinoma [ATAC-seq]

GEO Series GSE242080. Mus musculus. 6 samples. Type: Genome binding/occupancy profiling by high throughput sequencing.

openGEO-OpenNov 2023View details →
geo12/100

Local thermal ablation breaks immune tolerance in pacreatic cancer [RNA-seq 1]

GEO Series GSE214202. Mus musculus. 16 samples. Type: Expression profiling by high throughput sequencing.

openGEO-OpenNov 2024View details →
geo12/100

Transcriptomic comparison of two selective retinal cell ablation paradigms in zebrafish reveals shared and cell-specific regenerative responses

GEO Series GSE234646. Danio rerio. 138 samples. Type: Expression profiling by array.

openGEO-OpenJun 2023View details →
geo12/100

Analysis of Porcupine ablation within the uterine epithelium on gene expression within the uterus

GEO Series GSE96801. Mus musculus. 6 samples. Type: Expression profiling by array.

openGEO-OpenMar 2017View details →
zenodo8/100

Selective ablation of dehydrodolichyl diphosphate synthase in murine retinal pigment epithelium (RPE) causes RPE atrophy and retinal degeneration.

<p>Supplementary files for manuscript.</p>

restrictedFeb 2020View details →
ClinicalTrials.gov0/100

Outcomes of Ablation of Unresectable Pancreatic Cancer Using the NanoKnife Irreversible Electroporation (IRE) System

ClinicalTrials.gov study NCT02041936. IPD Sharing: Not stated. Countries: 1. Publications: 0.

restrictedIPD-UNDECIDEDFeb 2026View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.