Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
10,554
datasets available to search
ShareScore release 0.9.0
Dataset results
10,554 results for “measure”
Liquid chromatography measurement obtained from the chitin extracts of insect exuviae
<p>Chitin, a biopolymer present in fungi and arthropods, is a compound of interest for various applications, such as in the agricultural and medical fields. With the recently growing interest in the development of insect farming, the availability of chitin-containing residual streams, particularly the molting skins (exuviae), is expected to increase in the near future. For application purposes, accurate quantification of chitin in these insect sources is essential. Previous studies on chitin extraction and quantification often overlooked the purity of the extracted chitin, making the outcomes inconsistent and prone to overestimation. The present study aims to determine chitin content in the exuviae of three insect species mass-reared worldwide: black soldier fly (BSF), mealworm, and house cricket. Chitin was chemically extracted using acid and alkali treatments to remove minerals and proteins. The purity of extracted chitin was evaluated by hydrolyzing the chitin into glucosamine, followed by quantitative determination of the latter using two liquid chromatography methods: electrochemical detection (ECD) and tandem mass spectrometry (MS/MS). Both methods proved accurate and precise, without the need for labor-intensive derivatization steps. Pearson's correlation and Bland-Altman plots showed that the glucosamine determination results obtained by the two methods were comparable, and there is no consistent bias of one approach vs. the other. The chitin content in extracted residues ranged between 7.9 and 18.5%, with the highest amount<br> found in BSF puparium. In summary, the study demonstrated that (1) the residual streams of the insect farming industry have a great potential for utilization as an alternative chitin source, and (2) both LC-ECD and LC-MS/MS are reliable for the quantitative determination of glucosamine in insect chitin.</p>
Elasticity and damping ratio measurement of droplets on super-hydrophobic surfaces
<p>The elasticity of the droplet refers to the ability of the droplet in restoring to its original shape and ensuring its strong robustness. The measurement of the droplets' elasticity is vitally important in understanding the characteristics and mechanism of the droplet jumping, spreading, and coalescence. In this paper, we measured the elasticity and damping ratio of droplets with different viscosity. A plate coated with a hydrophobic layer pressed on a droplet, and the elastic force was recorded by an electronic balance. Meanwhile, a mathematical model was constructed to illustrate the change rate of the droplet area with the elastic force. By comparing the influence of volume and viscosity on elasticity, the results showed that work done by pressure converts into surface energy. And the elasticity of the droplet is provided by the surface tension and the damping ratio increases from 0.068 to 0.261.</p>
FIG. 3 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 3 Population structure of Shinisaurus crocodilurus in Vietnam. (A) Frequency histogram of snoutvent length of all encountered animals; (B) Frequency of individuals with original or regenerated tails for each nature reserve, p <0.05.
FIG. 6 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 6 Main threats to S. crocodilurus in Vietnam. (A) Coal-mining exploration close to the species' habitat; (B) Opening of the forest with roads to facilitate coal-mining throughout the nature reserves; (C) Preserved S. crocodilurus in alcohol, used for traditional medicine in Quang Ninh Province. Photos: M. Bernardes & M. van Schingen.
FIG. 2 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 2 Map of the current distribution of Shinisaurus crocodilurus. Red dots represent occurrence records.
FIG. 5 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 5 Slash and burn practices in Tay Yen Tu NR, Vietnam. (A) example of forest fire; (B) burned area cleared for agricultural purposes or exploration by the paper industry. Photos: M. Bernardes & M. van Schingen.
FIG. 1 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 1 Shinisaurus crocodilurus in its natural habitat in Tay Yen Tu NR, Vietnam. Photo: M. van Schingen.
FIG. 4 in Current status of the Crocodile Lizard Shinisaurus crocodilurus Ahl, 1930 in Vietnam with implications for conservation measures
FIG. 4 Distribution of different age classes of S. crocodilurus in Vietnam. (A) Frequency of observed juveniles, subadults and adults from three nature reserves, p <0.001; (B) Frequency shift (of juveniles, subadults and adults) in Tay Yen Tu NR between 2010 and 2013, p <0.05.
Plate boundary deformation at the Azores triple junction determined from continuous GPS geodetic measurements, 2000-2017
<p>Ground deformation in the Azores, at the triple junction between the Eurasian, Nubian, and North American plates, has been mapped with continuous GPS (Global Positioning System) geodetic measurements to improve tectonic motion estimates and for understanding volcanic unrest. We compute daily GPS positions, spanning almost 17 years (2000-2017), from 18 continuous GPS stations. The GPS time-series are analyzed by searching for discontinuities and periodic functions. Results show that Flores and Graciosa islands have displacements close to predicted North American and Eurasian plate motions, respectively, while São Miguel, Terceira, São Jorge, Faial and Pico islands have displacements in between predicted Eurasian and Nubian plate motions. The Eurasian-Nubian plate boundary in the Azores behaves as a diffuse ultra-slow oblique spreading center with focused deformation found in the Central Group and São Miguel Island. The velocity field is modeled by approximating segments of the Eurasian-Nubian plate boundary with vertical dislocations with right-lateral motion and opening below a locking depth. Best fitting models have deep motion in the range of 2.4-2.7 mm/yr directed N(76.5-78.8<sup>o</sup>)E. Such displacement accounts for more than half predicted Eurasian-Nubian relative plate motion. The modeling results suggest that the locking depth in the Central Group is about 17 km while in São Miguel is about 2 km. We found transient deformation at Fogo volcano, São Miguel Island, due to unrest activity mainly during 2003–2006 and 2011–2012, and local continuous subsidence in Terceira Island, attributed to a deflation source centered on the island.</p>
Measuring intraoperative surgical instrument use with radio-frequency identification
<p><strong>Objective:</strong> Surgical instrument oversupply drives cost, confusion, and workload in the operating room (OR). With an estimated 78-87% of instruments being unused, many health systems have recognized the need for supply refinement. By manually recording instrument use and tasking surgeons to review instrument trays, previous quality improvement initiatives have achieved an average 52% reduction in supply. While demonstrating the degree of instrument oversupply, previous methods for identifying required instruments are qualitative, expensive, lack scalability and sustainability, and are prone to human error. In this work, we aim to develop and evaluate an automated system for measuring surgical instrument use.</p> <p><strong>Materials and Methods:</strong> We present the first system to our knowledge that automates the collection of real-time instrument use data with radio-frequency identification (RFID). Over 15 breast surgeries, ten carpometacarpal (CMC) arthroplasties, and four craniotomies, instrument use was tracked by both a trained observer manually recording instrument use and the RFID system.</p> <p><strong>Results:</strong> The average Cohen's Kappa agreement between the system and the observer was 0.81 (near perfect agreement), and the system enabled a supply reduction of 50.8% in breast and orthopedic surgery. Over 10 monitored breast surgeries and one CMC arthroplasty with reduced trays, no eliminated instruments were requested, and both trays continue to be used as the supplied standard. Setup time in breast surgery decreased from 23 minutes to 17 minutes with the reduced supply.</p> <p><strong>Conclusion:</strong> The RFID system presented herein achieves a novel data stream that enables accurate instrument supply optimization.</p>
Bitstream Compaction iCE40 - Bitstreams and Reconfiguration Time Measurements
<p>The HDF5 file contains data from an experiment concerning bitstream compaction for Lattice iCE40 FPGAs.</p> <p>Four projects were synthesized with two different toolchains and afterwards compacted in two different levels, resulting in 24 bitstreams. The creation of each bitstream was repeated 100 times to guard against variations caused by errors in the toolchains or by the compaction. No such errors occured and the configuration is the same for every repetition.</p> <p>The reconfiguration time for each of the 24 bitstreams was measured 10.000 times.</p> <p>Toolchains:</p> <ul> <li>Lattice iCEcube2</li> <li>Open Source Toolchain (Yosys, nextpnr, Project Icestorm)</li> </ul> <p>Projects:</p> <ul> <li>empty: Completely empty project, that uses no FPGA resources.</li> <li>b12: A project from the ITC’99 benchmark suite.</li> <li>aes: A simple AES-128 encryption module.</li> <li>picosoc: RISC-V system on a chip</li> </ul> <p>Compaction levels:</p> <ul> <li>original: uncompacted bitstream</li> <li>builtin: compacted with two methods also available in iCEcube2</li> <li>compact: compacted with all five methods</li> </ul> <p>File structure:</p> <p>The data is organzied hierarchical. It is first split between bitstreams and measurements, then by toolchain, then by project and finally by compaction level.</p>
Ventilatory parameters measured in Madagascar hissing cockroaches during continuous gas exchange and DGCs
<p>This dataset is presented in the manuscript titled: 'Discontinuous gas exchange in Madagascar hissing cockroaches is not a consequence of hysteresis around a fixed PCO<sub>2</sub> threshold'; published in JEB. The primary purpose of this investigation was to test if discontinuous gas exchange cycles (DGCs) were caused by PCO<sub>2</sub> fluctuations around ventilatory setpoints. Madagascar hissing cockroaches were exposed to normoxic acapnia and treatments of either hypoxic acapnia, and normoxic hypercapnia, while displaying continious gas exchange, and DGCs. Hemolymph PO<sub>2 </sub>and PCO<sub>2</sub> were measured in conjunction with ventilatory frequency and VCO<sub>2 </sub>released. This data displays the changes in ventilatory parameters observed during ambient gas manipulations.</p>
Shapiro step measurements in (BiSb)2Te3 junctions
<p>Dataset and analysis code accompanying the manuscript "Fractional AC Josephson effect in a topological insulator proximitized by a self-formed superconductor," available at <a href="https://arxiv.org/abs/2110.01039">https://arxiv.org/abs/2110.01039</a>. This dataset includes measurements of Josephson junction devices with (BiSb)2Te3 weak links, whose Pd-Te superconducting leads are self-formed through deposition of Pd on the (BiSb)2Te3. In junctions with the prefix "Al", an Al layer is added to the superconducting leads following Pd deposition. The dataset includes transport measurements of Shapiro steps under radiofrequency excitation as well as DC electronic transport measurements. Analysis code is provided in the accompanying iPython notebooks.</p>
Selected Electric Field Measurement Campaigns data
<p>This presents the selected electric field measurement data acquired under several measurement campaigns in indoor and outdoor environments. </p> <p>This work was supported by the EU project 5GRFEX entitled – ‘Metrology for RF exposure from Massive MIMO 5G base station: Impact on 5G network deployment’ (this project has received funding from the support for impact (SIP) programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme), under European Association of National Metrology Institutes (EURAMET) Reference 18SIP02.</p> <p> </p>
Dataset for publication: Design and Characterization of a Magnetic Loop Antenna for Partial Discharge Measurements in Gas Insulated Substations
<p>Data set belonging to the IEEE Sensors Journal paper with DOI: <a href="https://doi.org/10.1109/JSEN.2021.3089084">10.1109/JSEN.2021.3089084</a></p> <p>Mier Escurra, Christian; Mor, Armando Rodrigo; Vaessen, Peter</p> <p><em>Design and Characterization of a Magnetic Loop Antenna for Partial Discharge Measurements in Gas Insulated Substation</em></p>
Selected processed 5G base station RF-EMF measurement data
<p>This presents the selected processed 5G base station (BS) radio frequency electromagnetic field (RF-EMF) measurement data acquired under measurement campaign in outdoor environment. This data links to the findings shown in Section 5 of D1 report at http://empir.npl.co.uk/5grfex/wp-content/uploads/sites/55/2022/01/updated-EMPIR-18SIP02-5GRFEX-Deliverable-Report-D1.pdf. </p> <p>This work was supported by the EU project 5GRFEX entitled – ‘Metrology for RF exposure from Massive MIMO 5G base station: Impact on 5G network deployment’ (this project has received funding from the support for impact (SIP) programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme), under European Association of National Metrology Institutes (EURAMET) Reference 18SIP02.</p>
Selected SSB-based RF-EMF Outdoor Measurement Campaigns data
<p>This presents the selected Synchronisation Signal Block (SSB) based radio frequency electromagnetic field (RF-EMF) measurement data acquired under measurement campaign in indoor environment. This data links to the findings shown in Section 4.2 of D1 report at http://empir.npl.co.uk/5grfex/wp-content/uploads/sites/55/2022/01/updated-EMPIR-18SIP02-5GRFEX-Deliverable-Report-D1.pdf. </p> <p>This work was supported by the EU project 5GRFEX entitled – ‘Metrology for RF exposure from Massive MIMO 5G base station: Impact on 5G network deployment’ (this project has received funding from the support for impact (SIP) programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme), under European Association of National Metrology Institutes (EURAMET) Reference 18SIP02.</p>
Selected SSB-based RF-EMF Indoor Measurement Campaigns data
<p>This presents the selected Synchronisation Signal Block (SSB) based radio frequency electromagnetic field (RF-EMF) measurement data acquired under measurement campaign in indoor environment. This data links to the findings shown in Section 3.3 of D1 report at http://empir.npl.co.uk/5grfex/wp-content/uploads/sites/55/2022/01/updated-EMPIR-18SIP02-5GRFEX-Deliverable-Report-D1.pdf. </p> <p>This work was supported by the EU project 5GRFEX entitled – ‘Metrology for RF exposure from Massive MIMO 5G base station: Impact on 5G network deployment’ (this project has received funding from the support for impact (SIP) programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme), under European Association of National Metrology Institutes (EURAMET) Reference 18SIP02.</p>
ESM of determination of transdermal rate of metallic microneedle array through impedance measurements-based numerical check screening algorithm
<p>Microneedle systems have been widely used in health monitoring, painless drug delivery, and medical cosmetology. Although many studies on microneedle materials, structures, and applications have been conducted, the applications of microneedles often suffered from issues of inconsistent penetration rates due to the complication of skin-microneedle interface. In this study, we demonstrated a methodology of determination of transdermal rate of metallic microneedle array through impedance measurements-based numerical check screening algorithm. Metallic sheet microneedle array sensors with different sizes were fabricated to evaluate different transdermal rates. In vitro sensing of hydrogen peroxide confirmed the effect of transdermal rate on the sensing outcomes. A FEM simulation model of a microneedle array revealed the monotonous relation between the transdermal state and test current. Accordingly, two methods were first derived to calculate the transdermal rate from the test current. First, an exact logic method provided the number of unpenetrated tips per sheet, but it required more rigorous testing results. Second, a fuzzy logic method provided an approximate transdermal rate on adjacent areas, being more applicable and robust to errors. Real-time transdermal rate estimation may be essential for improving the performance of microneedle systems, and this study provides various fundaments toward that goal.</p>
AMT-2021-217 (Berg, Chiodo, Georgin) Laboratory measurements of gas temperature, pressure, and flow rate..
<p>These data are laboratory measurements of gas temperature, pressure, and flow rate made in the development of a humidity generator.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.