Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
177
datasets available to search
ShareScore release 0.9.0
Dataset results
177 results for “359”
IODP Expedition 359 Interstitial water composite report
This composite report includes data from numerous interstitial water (IW) analyses (e.g., ICP-LIQUIDS and IONCHROM) in a variable set of columns. Each row combines the data from several tests (groups of measurements made on the same sample at the same time) for a particular IW sample. If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate analysis (ALKALINITY, ICP-LIQUIDS, IONCHROM, SALINITY, SPEC, TITRATOR, and potentially others). Major and minor elements were determined by inductively coupled plasma-atomic emission spectrocsopy (ICP-LIQUIDS). Cations and anions were measured by ion chromatography (IONCHROM). Complex ions were measured by colorimetric measurements using a UV-VIS spectrometer (SPEC). Alkalinity and chloride was measured by titration (ALKALINITY and TITRATOR). Dissolved carbon (DC), dissolved inorganic carbon (DIC), and dissolved organic carbon (DOC) were measured by combustion in a total organic carbon (TOC) analyzer. Salinity was measured by refractometer (SALINITY). pH was measured by ion-selective electrode as part of the alkalinity procedure and is reported in the ALKALINITY analysis.
IODP Expedition 359 Scanning electron microscope images
Microscopic images of discrete samples were acquired using a scanning electron microscope (SEM) and captured as image files. These files were uploaded along with a brief description and a record of the microscopic conditions when the image was taken.
IODP Expedition 359 ICP-AES elemental analysis (interstitial water)
Elemental concentration in interstitial water samples was measured by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). Data are presented by element-wavelength pair (e.g., more than one calcium line may be reported). Elemental lines for which data do not exist for a particular expedition will not appear.
IODP Expedition 359 Sample report
Report includes detailed information about samples taken for testing: location/depth, type/form factor, test, request number, and database identifier.
IODP Expedition 359 Bulk Density (GRA)
Gamma ray attenuation (GRA) data were acquired using a Cs-137 collimated source and a sodium iodide (thallium), or NaI(Tl), scintillation detector. The signal was calibrated using water and aluminum standards to provide a proxy for bulk density. This measurement was performed by a sensor mounted on either the Whole-Round Multisensor Logger (WRMSL) or the Special Task Multisensor Logger (STMSL); which track was used for a given data set is indicated in the data.
IODP Expedition 359 Section-half images
Digital section images were taken of the flat face of split cores on the Section Half Imaging Logger (SHIL) using a linescan camera at a resolution of 20 lines/mm (50 micron pixels). Cores were imaged as soon as possible after splitting to minimize color changes that occur through oxidation and drying. The SHIL produces TIF files as well as reduced-size JPG files. The TIF files are not kept online but users may request them from the <a href="mailto:database@iodp.tamu.edu">IODP-JRSO Data Librarian</a>.
IODP Expedition 359 Vane shear strength (Torvane)
Sediment strength was measured on section halves using a Humbolt Manufacturing Torvane handheld instrument. The Torvane is suitable for sediment not affected by cementation (i.e., saturated, clay-rich, soft sediment).
IODP Expedition 359 Titration
Various chemical constituents (most commonly chloride) were measured by titration using either an autotitrator (chloride) or a manual titrator (other compounds). Chloride was measured by ion-selective electrode and a silver nitrate titration until all chloride is bound as silver chloride.
IODP Expedition 359 Magnetic remanence (spinner)
Magnetic remanence was measured on discrete samples by an Agico JR-6A spinner magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization or remagnetization steps were performed on the samples (e.g., alternating field [AF] demagnetization, thermal demagnetization [TD], or isothermal remanent magnetization [IRM]).
IODP Expedition 359 Spectrophotometry
Interstitial water constitutents were measured by UV-VIS spectrometry using colorimetric methods (e.g., ammonium, nitrate, nitrite, phosphate, silica, and sulfide) by an Agilent CARY 100 UV-VIS spectrophotometer.
IODP Expedition 359 Source rock analyzer (SRA)
SRA is run for the purpose of safety monitoring and yields information about thermal maturation and source of hydrocarbons, as well as petroleum potential, in the sediment or rocks at a drilled site. Samples are heated in a pyrolysis oven in an inert atmosphere to quantitatively and selectively determine free hydrocarbons contained in the sample and the hydrogen- and oxygen-containing compounds that are volatilized during the cracking of unextractable organic matter in the sample (kerogen).
IODP Expedition 359 Section summary
Report includes data for individual core sections: coring/drilling depths and recovery, database identifiers for the whole section and section halves, and number of samples taken from the section before and after splitting.
IODP Expedition 359 Thermal conductivity
Thermal conductivity was measured using the heated needle method in either full-space needle configuration (soft/saturated sediments) or half-space needle configuration (harder materials) of a TeKa Berlin TK-04 thermal conductivity meter. Heat is applied to the sample and then thermal equilibrium is sought. The heating and equilibration curve is reduced to derive the thermal conductivity value. Raw data are stored if a user wishes to do off-line or postexpedition reduction.
IODP Expedition 359 Formation temperature
Formation temperature was measured by the advanced piston corer temperature tool (APCT-3), Sediment Temperature Tool (SET), or sediment temperature pressure tool (SETP) and reduced to in situ temperature and (for SETP) pressure estimates. These data are compiled per instrument run and assigned to a core (the core cut with the APCT-3 cutting shoe or the core following the SET deployment).
IODP Expedition 359 Visual core description
Descriptions of samples, generally at the section half and smear slide or thin section scale, were performed by shipboard scientists and recorded in the JRSO description software. Descriptive data for both macroscopic and microscopic examination were collected in a Microscoft Excel workbook by hole. A zip file of the entire expedition's observations is also available.
IODP Expedition 359 Carbonates composite report
This composite report includes data from two analyses (total carbon from Elemental analysis [CHNS], and inorganic carbon from [Coulometer]). Each row combines the CHNS and Coulometer data from measurements made on the same sample at the same time for a particular section and section offset (depth). If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate data type (Elemental analysis and Coulometer). If the same sample was measured multiple times by any of the methods, results in the report will be combined on one line where possible. Each additional replicate result will be shown in subsequent rows and will be combined where possible. Report includes results for carbon forms: total, inorganic, calcium carbonate, and organic by difference, along with total hydrogen, nitrogen, and sulfur.
IODP Expedition 359 Core summary
Report includes detailed core data: drilling and coring depths, advancement, recovered core length measured on the catwalk and final curated length, core recovery, and sections cut.
IODP Expedition 359 Alkalinity and pH
Alkalinity was determined by Gran titration with an autotitrator (Metrohm 794 basic Titrino) using 0.1 M HCl at 20 degrees C. Report includes alkalinity, correction factor (if applicable), and pH.
IODP Expedition 359 Core composite images
A digital composite image (PNG) is made for each core comprising core sections scanned using a line-scan camera. The composite layout is equivalent to traditional core table photos. Top left is top of core; color and meter rule references are included.
IODP Expedition 359 Closeup images
Close-up images taken by digital cameras as requested by the science party, typically when the section-half image is not sufficient. Close-up photographs of the areas of interest may be taken from whole-round sections, pieces, or section halves in sediments and rock.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.