Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
461
datasets available to search
ShareScore release 0.9.0
Dataset results
461 results for “hf”
IceBridge UAF L1B HF Geolocated Radar Echo Strength Profiles V001
This data set contains radar echograms acquired by the University of Alaska Fairbanks High-Frequency Radar Sounder over select glaciers in Alaska. The data are provided in HDF5 formatted files, which include important metadata for interpreting the data. Browse images are also available.
Transcriptomic profile of high and low fertile HF crossbred bulls.
GEO Series GSE154503. Bos taurus. 2 samples. Type: Expression profiling by array.
Modulation of LPS-stimulated BV2 microglial cells by Amauroderma rugosum hexane fraction (HF)
GEO Series GSE81435. Mus musculus. 8 samples. Type: Expression profiling by array.
The role of PCD-related circRNA/miRNA/mRNA regulatory network in the HF with AF
GEO Series GSE235757. Homo sapiens. 8 samples. Type: Expression profiling by high throughput sequencing.
EWAT transcriptomic analysis in male rat offspring of HF-fed dams treated with GSPE or vehicle during pregnancy and lactation
GEO Series GSE57005. Rattus norvegicus. 16 samples. Type: Expression profiling by array.
Differential gene expression in hair follicle-derived germline stem cells (HFGSCs) and germline stem cells (GSCs) compared with hair follicle (HF) cells.
GEO Series GSE98019. Mus musculus. 6 samples. Type: Expression profiling by array.
Expression data from livers from mice receiving high-fat (HF) diets supplemented with different berries
GEO Series GSE66711. Mus musculus. 36 samples. Type: Expression profiling by array.
DNA Methylation profile in hypothalamus for mouse offspring with maternal high fat (HF), low protein (LP) and control (CO) diets
GEO Series GSE79619. Mus musculus. 9 samples. Type: Methylation profiling by high throughput sequencing.
Transcriptional responses of fibroblast like synoviocytes to TNFa in the presence or absence of Halofuginone (HF)
GEO Series GSE145205. Homo sapiens. 30 samples. Type: Expression profiling by high throughput sequencing.
Bovine pituitary gland gene expression database of Polish-HF, Polish-Red and Hereford cattle breeds.
GEO Series GSE114230. Bos taurus. 18 samples. Type: Expression profiling by high throughput sequencing.
Raw data of the publication: Does moderate hyperkalemia influence survival in HF? Insights from the MECKI score data (Int J Cardiol . 2023 Jan 15;371:273-277. doi: 10.1016/j.ijcard.2022.09.030. Epub 2022 Sep 15)
<p><strong>Background: </strong>The prognostic role of moderate hyperkalemia in reduced ejection fraction (HFrEF) patients is still controversial. Despite this, it affects the use of renin-angiotensin-aldosterone system inhibitors (RAASi) with therapy down-titration or discontinuation.</p> <p><strong>Objectives: </strong>Aim of the study was to assess the prognostic impact of moderate hyperkalemia in chronic HFrEF optimally treated patients.</p> <p><strong>Methods and results: </strong>We retrospectively analyzed MECKI (Metabolic Exercise test data combined with Cardiac and Kidney Indexes) database, with median follow-up of 4.2 [IQR 1.9-7.5] years. Data on K<sup>+</sup> levels were available in 7087 cases. Patients with K<sup>+</sup> plasma level ≥ 5.6 mEq/L and < 4 mEq/L were excluded. Remaining patients were categorized into normal >4 and < 5 mEq/L (n = 4826, 68%) and moderately high ≥5.0 and ≤ 5.5 mEq/L (n = 496, 7%) K<sup>+</sup>. Then patients were matched by propensity score in 484 couplets of patients. MECKI score value was 7% [IQR 3.1-14.1%] and 7.3% [IQR 3.4-15%] (p = 0.678) in patients with normal and moderately high K<sup>+</sup> values while cardiovascular mortality events at two years follow-up were 41 (4.2%) and 33 (3.4%) (p = 0.333) in each group respectively.</p> <p><strong>Conclusions: </strong>Moderate hyperkalemia does not influence patients' outcome in a large cohort of ambulatory HFrEF patients.</p>
Prognostic value of left atrial strain quantification from 2D ultrasound imaging in post-ischemic heart failure patients: evidence from the REMODEL-HF study.
<p>Frigelli M, Sturla F, Milani V, Ramputi L, Citarella M, Menicanti L, Votta E, Castelvecchio S. Prognostic value of left atrial strain quantification from 2D ultrasound imaging in post-ischemic heart failure patients: evidence from the REMODEL-HF study. Int J Cardiol. 2022 Sep 1;362:183-189. doi: 10.1016/j.ijcard.2022.04.071. Epub 2022 Apr 30. PMID: 35504452.</p> <p>Abstract</p> <p><strong>Background: </strong>Left atrial (LA) function can be effectively assessed by measuring longitudinal LA strain (LAS) via two-dimensional speckle tracking echocardiography (2DSTE). Here, we test 2DSTE-based LAS as marker of different left ventricle (LV) remodeling patterns and as prognostic index in ischemic heart failure (HF) candidates to surgical ventricular reconstruction.</p> <p><strong>Methods: </strong>We retrospectively considered ischemic HF patients with anterior (group A, n=130) or posterior (group P, n=48) LV remodeling. Based on 2D ultrasound, LV and LA morpho-functional parameters were quantified including reservoir (LAS<sub>Res</sub>), conduit (LAS<sub>Cond</sub>) and booster (LAS<sub>Boost</sub>) LAS. We tested their capability to discriminate between groups A and P, and their group-specific prognostic significance for the composite end-point of death or HF re-hospitalization at follow-up (mean follow-up time=40 months, range 3-101 months).</p> <p><strong>Results: </strong>Group A and group P displayed similar end-diastolic (p=0.89) and end-systolic (p=0.33) LV volume index, and LA volume index LAVi (p=0.44) corrected for the degree of mitral regurgitation. As compared to group P, group A revealed a significant reduction in LAS<sub>Boost</sub> (9.2±0.4% vs. 11.1±0.7%, p=0.04) and a non-significant reduction in LAS<sub>Res</sub> (16.9±0.7% vs. 19.3±1.1%, p=0.06). Kaplan-Meier curves showed that the median LAS<sub>Res</sub> and LAS<sub>Boost</sub> values effectively stratified patients based on their prognosis in the overall study population (Log-rank p=0.002 and Log_rank p<0.0001) and in group A, where the association was stronger for LAS<sub>Boost</sub> (Log-rank p<0.001) than for LAS<sub>Res</sub> (Log-rank p=0.013).</p> <p><strong>Conclusions: </strong>2DSTE-based LAS assessment is affordable, repeatable and non-invasive, and could add clinically-relevant mechanistic insight and prognostic value in the stratification of ischemic HF patients.</p>
Translatome of floral buds, in vivo pollinated pollen tubes, and in vitro cultured pollen grains/tubes from LAT52-HF-RPL18 Arabidopsis
GEO Series GSE43299. Arabidopsis thaliana. 9 samples. Type: Expression profiling by array.
THEMIS-E: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-D: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-C: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-B: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-A: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
The formation of modern mature continental crust: Evidence from zircon ages, Hf-O isotopes and bulk geochemistry of the Menglian Batholith, SE Tibet
<p>The dataset is the all data used in The formation of modern mature continental crust: Evidence from zircon U-Pb age dating, Hf-O isotopes and geochemistry of the Menglian Batholith, SE Tibet and associated Data Availability Statement</p>
doi_dedup___::059d8a4c25242e95ec7b88d7ee3c1d25
Open the record for dataset details and reuse information.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.