Skip to main content
ConductScienceScienceDex
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

56

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

56 results for “Finite Element Modelling”

Learn how ShareScore rates datasets ↗
dryad28/100

Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf

Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation is difficult or impossible, the choice of model parameters and their effects on the results become increasingly important, especially in comparing outputs to infer function. To evaluate the extent to which performance measures are affected by initial model input, we tested the sensitivity of bite force, strain energy, and stress to changes in seven parameters that are required in testing craniodental function with FEA. Simulations were performed on FE models of a Gray Wolf (Canis lupus) mandible. Results showed that unilateral bite force outputs are least affected by the relative ratios of the balancing and working muscles, but only ratios above 0.5 provided balancing-working side joint reaction force relationships that are consistent with experimental data. The constraints modeled at the bite point had the greatest effect on bite force output, but the most appropriate constraint may depend on the study question. Strain energy is least affected by variation in bite point constraint, but larger variations in strain energy values are observed in models with different number of tetrahedral elements, masticatory muscle ratios and muscle subgroups present, and number of material properties. These findings indicate that performance measures are differentially affected by variation in initial model parameters. In the absence of validated input values, FE models can nevertheless provide robust comparisons if these parameters are standardized within a given study to minimize variation that arise during the model-building process. Sensitivity tests incorporated into the study design not only aid in the interpretation of simulation results, but can also provide additional insights on form and function.

opencc-zeroDec 2010View details →
dryad28/100

Data from: Convergence analysis of a finite element skull model of Herpestes javanicus (Carnivora, Mammalia): implications for robust comparative inferences of biomechanical function

Predictions of skull biomechanical capability based on virtual models constitute a valuable data source for testing hypotheses about craniodental form and feeding behavior. Such comparative analyses also inform dietary reconstruction in extinct species. 3D modeling using Finite Element (FE) methods is a common technique applied to the comparative analysis of craniodental function in extinct and extant vertebrates. However, taxonomically diverse skull models in the literature often are not directly comparable to each other, in part because of distinctions in how boundary conditions are defined, but also because of substantial differences in the number of FEs composing the models. In this study, we test whether a conventional convergence test is adequate in identifying the minimum number of FEs needed to achieve internally stable results for a single species. We constructed a series of skull models of Herpestes javanicus, and simulated unilateral biting across the dentition; the models differed in the number of FEs, degrees of freedom at the joint and bite point constraints, and type of tetrahedral FEs used. We found that convergence patterns differed across constraint types, FE quantities, and bite position simulated. Four-noded tetrahedral (tet-4) FE models with relaxed constraints produced the most stable measurements compared to over-constrained tet-4 models and to relaxed tet-10 models. In absence of an optimal FE quantity from convergence testing, we propose a broadly applicable sub-sampling protocol, whereby average measurement values across multiple models per specimen are used for among-species comparisons. A regime of sampling three low FE quantity models produced the closest estimates of mean measurement values relative to larger model sets, being within the 95% bootstrap estimated confidence intervals. Future studies should focus on identifying sources of variation associated with other FE modeling protocols, so that they can be accounted for before biomechanical attributes from these simulations are used to infer form–function linkage.

opencc-zeroDec 2013View details →
zenodo28/100

Model codes and data for ``A control volume finite element model for predicting the morphology of cohesive-frictional debris flow deposits"

<p>The code and the dataset can be read/run by using Matlab. The description is as follows:</p> <p>1. Dataset (field_data) includes transect data of three field debris flow deposits from Coussot et al. (1996). The data can be read and calibrated with the analytical solution by the code field_calibration.m.</p> <p>2. Dataset (data_T01-T04, T11-T15_DT) includes experimental fan topography data, calibrated parameters, and simulation outputs.&nbsp;</p> <p>3. Two calibration codes are used for the model parameter calibrations of the two sets of experiments.</p> <p>4. Function aggradation_DT.m is the CVFEM model for simulating fan morphology. Use&nbsp;CVFEM_exp_simulation.m code to run simulations for the experiments.</p>

opencc-by-4.0Dec 2021View details →
ClinicalTrials.gov28/100

Concordance of Pelvic Organ Mobility Measurements Between the Finite Element Model and the Dynamic Pelvic Floor MRI in Patients Undergoing a Sacrospinofixation Surgery

ClinicalTrials.gov study NCT04551859. IPD Sharing: Not stated. Countries: 0. Publications: 9.

restrictedIPD-UNDECIDEDFeb 2026View details →
dryad28/100

Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf

Open the record for dataset details and reuse information.

publicMar 2011View details →
dryad28/100

Data from: Convergence analysis of a finite element skull model of Herpestes javanicus (Carnivora, Mammalia): implications for robust comparative inferences of biomechanical function

Open the record for dataset details and reuse information.

publicOct 2015View details →
dryad28/100

Data from: Finite element modelling vs. classic beam theory: comparing methods for stress estimation in a morphologically diverse sample of vertebrate long bones

Open the record for dataset details and reuse information.

publicDec 2012View details →
dryad28/100

Data from: Comparative finite-element analysis: a single computational modeling method can reliably estimate the mechanical properties of porcine and human vertebrae

Open the record for dataset details and reuse information.

publicApr 2015View details →
dryad24/100

Data from: The function(s) of the bone ornamentation in the crocodylomorph osteoderms: a biomechanical model based on a finite element analysis

This paper aims at assessing the influence of the bone ornamentation and, specifically, of the associated loss of bone mass on the mechanical response of the crocodylomorph osteoderms. To this aim, we have performed three dimensional modeling and finite element analyses on a sample which includes both extant dry bones and well-preserved fossils tracing back to the Late Triassic. We simulated an external attack under variable angles on the apical surface of each osteoderm and further repeated the simulation on an equivalent set of smoothed 3D-modeled osteoderms. The comparative results evidenced that the presence of an apical sculpture has no significant influence on the von Mises stress distribution in the osteoderm volume although it involves a slight increase in its numerical score. Moreover, performing parametric analyses, we evidenced that the Young's modulus in the osteoderm which may vary depending on the bone porosity, the collagen fiber orientation or the calcification density has no impact on the von Mises stress distribution inside the osteoderm volume. As the crocodylomorph bone ornamentation is continuously remodeled by pit resorption and secondary bone deposit, we assume that the apical sculpture may be the outcome of a "trade-off" between the bone mechanical resistance and the implication in physiological functions. These physiological functions are indeed based on the set-up of a bone superficial vessel network and/or on the recurrent release of mineral elements into the plasma: heat transfers when basking and respiratory acidosis buffering during prolonged apnea in neosuchians and teleosaurids; compensatory homeostasis in response to general calcium deficiencies. On a general morphological aspect, the osteoderm geometrical variability within our sample lead us to assess that the global osteoderm geometry (whether square or rectangular) does not influence the von Mises stress whereas the presence of a dorsal keel would rather reduce the stress along the vertical axis.

opencc-zeroDec 2017View details →
zenodo24/100

Data supporting: A Paradigm Shift to Assembly-like Finite Element Model Updating

Open the record for dataset details and reuse information.

restrictedgpl-3.0-or-laterOct 2024View details →
zenodo24/100

Models and data in support of "EMFEM: a parallel 3D modeling code for frequency-domain electromagnetic method using goal-oriented adaptive finite element method"

<p>These directories contain the model and data files for &quot;EMFEM: a parallel 3D modeling code for frequency-domain electromagnetic method using goal-oriented adaptive finite element method&quot;.<br> &nbsp;</p>

opencc-by-4.0Jun 2023View details →
ClinicalTrials.gov24/100

Establish Finite Element Mesh of the Numerical Models of the Thoracic Aorta

ClinicalTrials.gov study NCT00155480. IPD Sharing: Not stated. Countries: 1. Publications: 0.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov24/100

Finite Element Modelling of Le Fort I Osteotomy Fixation : PSI vs Miniplates

ClinicalTrials.gov study NCT07365657. IPD Sharing: Not stated. Countries: 1. Publications: 0.

restrictedIPD-UNDECIDEDFeb 2026View details →
dryad24/100

Data from: The function(s) of the bone ornamentation in the crocodylomorph osteoderms: a biomechanical model based on a finite element analysis

Open the record for dataset details and reuse information.

publicNov 2018View details →
dryad24/100

Data from: Finite-element analysis of microwave scattering from a three-dimensional human head model for brain stroke detection

Open the record for dataset details and reuse information.

publicJun 2018View details →
zenodo12/100

Vacuum Preloading Performance Assesment Using Monitoring Data Interpretation and Finite Element Modelling

Open the record for dataset details and reuse information.

restrictedcc-by-4.0Nov 2024View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.