Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
755
datasets available to search
ShareScore release 0.9.0
Dataset results
755 results for “angiography”
MR Pulmonary Angiography to Replace CT Pulmonary Angiography for Patients With a Suspicion of a Pulmonary Embolism
ClinicalTrials.gov study NCT05879380. IPD Sharing: NO. Countries: 0. Publications: 0.
Patient Tailored Contrast Volume for Preoperative CT Angiography of the Aorta
ClinicalTrials.gov study NCT05716568. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Randomized Comparison of Radiation Exposure in Coronary Angiography Between Right Conventional and Left Distal Radial Artery Approach
ClinicalTrials.gov study NCT04023838. IPD Sharing: NO. Countries: 0. Publications: 0.
Cardiac CT Angiography in Patients With Acute Ischemic Stroke
ClinicalTrials.gov study NCT06176872. IPD Sharing: NO. Countries: 0. Publications: 0.
Optical Coherence Tomography Angiography-OCTA Dataset for Detection of Diabetic Retinopathy
<p>This dataset consists of 268 OCTA images acquired on Optovue Avanti Edition for 179 patients. Out of 262, 133 are left-eye images and 135 are right-eye images. The acquisition is done at Natasha Eye Care and Research Institute, Pimple Saudager Pune. This dataset is curated for early detection of Diabetic Retinopathy and contains three categories of data viz NO_DR, Mild_DR, and Moderate_DR.</p>
ROSE: Retinal OCT-Angiography segmentation dataset
<p>Retinal OCT-Angiography Vessel Segmentation Dataset (ROSE) is now open source. It includes two subsets: <strong>ROSE-1</strong> and <strong>ROSE-2</strong>. </p> <ul> <li><strong>ROSE-1</strong> subset consists of a total of <strong>117 </strong>OCTA images from 39 subjects (26 with disease and the rest are healthy control) and was split into 90 images for training and 27 images for testing. Each subject has <em>en face</em> angiograms of superficial (SVC), deep (DVC), and the inner retinal vascular plexus that includes both SVC and DVC (SVC+DVC) respectively. All the OCTA scans were captured by the <u>RTVue XR Avanti SD-OCT system (Optovue, USA) equipped with AngioVue software</u>, with image resolution of 304 × 304 pixels. The scan area was 3×3 mm<sup>2</sup> area centred at the fovea. The manual annotations of these vascular network were graded by image experts and clinicians, and the consensus of them was then used as the groundtruth. Two different types of vessel annotations are available: <strong>centerline-level</strong> and <strong>pixel-level</strong> annotation. </li> <li><strong>ROSE-2</strong> subset contains a total of <strong>112</strong> OCT-A images of 112 eyes acquired by <u>Heidelberg OCT2 system with Spectralis software (Heidelberg Engineering, Heidelberg, Germany) </u>and was split into 90 images for training and 22 images for testing. All the images in this dataset are the en face angiograms of SVC within a 3×3 mm<sup>2</sup> area centred at the fovea, and each image was resized into a grayscale image with 840 × 840 pixels. All the visible retinal vessels were manually traced using an in-house program written in Matlab (Mathworks R2018, Natwick) by an experienced clinical ophthalmologist. </li> </ul> <p>code: <a href="https://github.com/iMED-Lab/OCTA-Net-OCTA-Vessel-Segmentation-Network">iMED-Lab/OCTA-Net-OCTA-Vessel-Segmentation-Network (github.com)</a></p> <p><strong>ROSE-O</strong> is a retinal structure detection dataset of OCTA images, with precise manual annotations of RV, RVJ and the FAZ. It contains 117 images which were captured using the <u>Optovue Avanti RTVue XR with AngioVue software (Optovue, Fremont, USA)</u>: the images have a resolution of 304×304 pixels. The SVC, DVC and IVC angiograms of each participant were obtained by the device. </p> <p>code: <a href="https://github.com/iMED-Lab/VAFF-Net">https://github.com/iMED-Lab/VAFF-Net</a></p>
Dataset related to the article: "CT Perfusion Versus Coronary CT Angiography in Patients With Suspected In-Stent Restenosis or CAD Progression"
<p>This record contains raw data related to the article "CT Perfusion Versus Coronary CT</p> <p>Angiography in Patients With Suspected</p> <p>In-Stent Restenosis or CAD Progression"</p> <p>OBJECTIVES The goal of this study was to assess the diagnostic performance of coronary computed tomography</p> <p>angiography (CTA) alone, adenosine-stress myocardial perfusion assessed by computed tomography (CTP) alone, and</p> <p>coronary CTA þ CTP by using a 16-cm Z-axis coverage scanner versus invasive coronary angiography (ICA) and fractional</p> <p>flow reserve (FFR) as the clinical standard.</p> <p>BACKGROUND Diagnostic performance of coronary CTA for in-stent restenosis detection is still challenging. Recently,</p> <p>CTP showed additional diagnostic power over coronary CTA in patients with suspected coronary artery disease. However,</p> <p>few data are available on CTP performance in patients with previous stent implantation.</p> <p>METHODS Consecutive stable patients with previous coronary stenting referred for ICA were enrolled. All patients</p> <p>underwent stress myocardial CTP and rest CTP þ coronary CTA. Invasive FFR was performed during ICA when clinically</p> <p>indicated. The diagnostic rate and diagnostic accuracy of coronary CTA, CTP, and coronary CTA þ CTP were evaluated in</p> <p>stent-, territory-, and patient-based analyses.</p> <p>RESULTS In the 150 enrolled patients (132 men; mean age 65.1 9.1 years), the CTP diagnostic rate was significantly</p> <p>higher than that of coronary CTA in all analyses (territory based [96.7% vs. 91.1%; p < 0.0001] and patient based [96%</p> <p>vs. 68%; p < 0.0001]). When ICA was used as gold standard, CTP diagnostic accuracy was significantly higher than that</p> <p>of coronary CTA in all analyses (territory based [92.1% vs. 85.5%, p < 0.03] and patient based [86.7% vs. 76.7%,</p> <p>p < 0.03]). The concordant coronary CTA þ CTP assessment exhibited the highest diagnostic accuracy values versus ICA</p> <p>(95.8%in the territory-based analysis). The diagnostic accuracy of CTP was significantly higher than that of coronary CTA</p> <p>(75% vs. 30.5%; p < 0.001). The radiation exposure of coronary CTA þ CTP was 4.15 1.5 mSv.</p> <p>CONCLUSIONS In patients with coronary stents, CTP significantly improved the diagnostic rate and accuracy of coronary</p> <p>CTA alone compared with both ICA and invasive FFR as gold standard.</p>
DATASET RELATED TO THE ARTICLE "Interpretability of coronary CT angiography performed with a novel whole-heart coverage high-definition CT scanner in 300 consecutive patients with coronary artery bypass grafts"
<p>This record contains raw data related to the article: Interpretability of coronary CT angiography performed with a novel wholeheart</p> <p>coverage high-definition CT scanner in 300 consecutive patients with</p> <p>coronary artery bypass grafts'</p> <p>Aims: Coronary CT angiography (CCTA) is an accurate non-invasive tool for the evaluation of coronary artery</p> <p>bypass graft (CABG). However, inability to sustain a long breath-hold, high heart rate (HR) and atrial fibrillation</p> <p>may affect image quality. Moreover, radiation exposure is still a matter of some concern. A scanner combining</p> <p>0.23-mm spatial resolution, new iterative reconstruction and fast gantry rotation time has been recently introduced</p> <p>in the clinical field. The aims of our study were to evaluate interpretability, radiation exposure and</p> <p>diagnostic accuracy of CCTA performed with the latest generation of cardiac-CT scanners compared to invasive</p> <p>coronary angiography (ICA) in the assessment of bypass grafts, and non-grafted and post-anastomotic native</p> <p>coronary arteries.</p> <p>Methods and results: We prospectively enrolled 300 patients undergoing clinically indicated CCTA with a 16-cm</p> <p>z-axis coverage, 256-detector rows, and 0.28-sec gantry rotation time scanner. Coronary artery and graft interpretability,</p> <p>image quality and effective dose (ED) were assessed in all patients and diagnostic accuracy was</p> <p>evaluated in a subgroup of 100 patients who underwent ICA.</p> <p>Mean HR during the scan was 69.6 ± 10.8. Sinus rhythm was present in 118 patients with HR < 75 bpm</p> <p>and in 112 patients with HR≥75 bpm, while 70 patients had atrial fibrillation. CABG interpretability was</p> <p>100%. Compared to ICA, CCTA was able to correctly detecting occlusions or significant stenoses of all CABG</p> <p>segments. Overall interpretability of native coronary segments was 95.6%. Sensitivity, specificity, positive</p> <p>predictive value, negative predictive value and accuracy of coronary arteries were 98.3%, 97.4%, 93.1%, 99.3%</p> <p>and 96.5%, respectively. The diagnostic accuracy in a patient based analysis was 95.2%. Mean ED was</p> <p>3.14 ± 1.7 mSv.</p> <p>Conclusions: The novel whole-heart coverage CT scanner allows to evaluating CABG and native coronary arteries</p> <p>with excellent interpretability and low radiation exposure even in the presence of unfavorable heart rhythm.</p>
Data set from Varga A, Di Leo G, Banga PV, Csobay-Novák C, Kolossváry M, Maurovich-Horvat P, Hüttl K. Multidetector CT angiography of the Circle of Willis: association of its variants with carotid artery disease and brain ischemia. Eur Radiol. 2019 Jan;29(1):46-56. doi: 10.1007/s00330-018-5577-x. Epub 2018 Jun 19. PMID: 29922933; PMCID: PMC6291432.
<p>Data set from the article Data set from Varga A, Di Leo G, Banga PV, Csobay-Novák C, Kolossváry M, Maurovich-Horvat P, Hüttl K. Multidetector CT angiography of the Circle of Willis: association of its variants with carotid artery disease and brain ischemia. Eur Radiol. 2019 Jan;29(1):46-56. doi: 10.1007/s00330-018-5577-x. Epub 2018 Jun 19. PMID: 29922933; PMCID: PMC6291432.</p> <p>This is the abstract</p> <p><strong>Purpose: </strong> (1) to estimate the prevalence of Circle of Willis (CoW) variants in patients undergoing carotid endarterectomy, (2) to correlate these variants to controls and (3) cerebral ischemia depicted by computed tomography (CT).</p> <p><strong>Materials and methods: </strong> After Institutional Review Board approval, data of 544 carotid endarterectomy patients (331 males, mean age 69±8 years) and 196 controls (117 males, mean age 66±11 years) who underwent brain CT and carotid CT angiography (CTA) were retrospectively analysed. Two observers independently classified each CoW segment as normal, hypoplastic (diameter <0.8 mm) or non-visualized. Four groups of CoW variants based on the number of hypoplastic/non-visualized segments were correlated with clinical data (ANOVA, χ<sup>2</sup> and multivariate logistic regression analysis). Intra- and inter-observer agreement was estimated using Cohen κ statistics.</p> <p><strong>Results: </strong> High prevalence of CoW variants (97%) and compromised CoW (81%) was observed in the study group and significant difference was found in the distribution of CoW variants compared to controls (p<0.001), internal carotid artery (ICA) stenosis being the only independent predictor of CoW morphology (p<0.001). Significant correlation was found between CoW configuration and brain ischemia in the study group (p=0.002). ICA stenosis of ≥90% was associated to higher rate of ipsilateral A1 hypoplasia/non-visualization (p<0.001). Intra- and inter-observer agreement was from substantial to almost perfect (Cohen κ=0.75-1.0).</p> <p><strong>Conclusion: </strong> Highly variable CoW morphology was demonstrated in patients undergoing endarterectomy compared to controls. Likely compromised CoW in relation to cerebral ischemia was observed in a large cohort of carotid endarterectomy subjects.</p> <p><strong>Key points: </strong> • CoW variant distribution significantly differed in the study and control groups (p<0.001). • ICA stenosis was the only independent predictor of CoW morphology (p<0.001). • Severely compromised CoW configuration showed significant association with brain ischemia (p=0.002).</p>
Dataset related to article "Safety of metformin continuation in diabetic patients undergoing invasive coronary angiography: the NO-STOP single arm trial"
<p>This record contains raw data related to article "Safety of metformin continuation in diabetic patients undergoing invasive coronary angiography: the NO-STOP single arm trial"</p><p><strong> Abstract</strong></p><p>Background: Despite paucity of data, it is common practice to discontinue metformin before invasive coronary angiography due to an alleged risk of Metformin-Associated Lactic Acidosis (M-ALA). We aimed at assessing the safety of metformin continuation in diabetic patients undergoing coronary angiography in terms of significant increase in lactate levels.</p><p>Methods: In this open-label, prospective, multicentre, single-arm trial, all diabetic patients undergoing coronary angiography with or without percutaneous coronary intervention at 3 European centers were screened for enrolment. The primary endpoint was the increase in lactate levels from preprocedural levels at 72-h after the procedure. Secondary endpoints included contrast associated-acute kidney injury (CA-AKI), M-ALA, and all-cause mortality.</p><p>Results: 142 diabetic patients on metformin therapy were included. Median preprocedural lactate level was 1.8 mmol/l [interquartile range (IQR) 1.3-2.3]. Lactate levels at 72 h after coronary angiography were 1.7 mmol/l (IQR 1.3-2.3), with no significant differences as compared to preprocedural levels (p = 0.91; median difference = 0; IQR - 0.5 to 0.4 mmol/l). One patient had 72-h levels ≥ 5 mmol/l (5.3 mmol/l), but no cases of M-ALA were reported. CA-AKI occurred in 9 patients (6.1%) and median serum creatinine and estimated glomerular filtration rate remained similar throughout the periprocedural period. At a median follow-up of 90 days (43-150), no patients required hemodialysis and 2 patients died due to non-cardiac causes.</p><p>Conclusions: In diabetic patients undergoing invasive coronary angiography, metformin continuation throughout the periprocedural period does not increase lactate levels and was not associated with any decline in renal function. </p>
The Macular Choriocapillaris Flow in Glaucoma and Within-Day Fluctuations: An Optical Coherence Tomography Angiography Study
<p>Raw data of the study, can be available upon request</p>
Peripheral artery disease: how much inter-leg symmetry? A contrast-enhanced magnetic resonance angiography study
<p>Dataset from the article Secchi F, Di Leo G, Delnevo A, Alì M, D'Angelo ID, Nardella VG, Sardanelli F. Peripheral artery disease: how much inter-leg symmetry? A contrast-enhanced magnetic resonance angiography study. Medicine (Baltimore). 2020 Apr;99(16):e19637. doi: 10.1097/MD.0000000000019637. PMID: 32311934; PMCID: PMC7220080.</p> <p>Abstract</p> <p>The aim of this observational retrospective study was to qualitatively and quantitatively evaluate the symmetry of atherosclerotic plaques in patients with peripheral artery disease (PAD) undergoing contrast-enhanced magnetic resonance angiography of lower limbs. We retrospectively evaluated the peripheral magnetic resonance angiography of 82 patients considering the iliac, femoral and tibial arteries. Stenosis was scored 0 (none), 1 (<50%), 2 (50%-74%), 3 (75%-99%), and 4 (occluded). Symmetry was quantified as the percentage of bilaterally-diseased arteries and using the inter-leg absolute score difference (0-4). Signs test and Cohen κ were also calculated. Seventy-one (87%) patients had ≥1 bilaterally-diseased artery, and 168 (20%) of 820 artery pairs were bilaterally affected. At least 1 bilateral stenosis was observed from 11% (right internal iliac) to 73% (right superficial femoral). All 10 arteries showed symmetry, none of the inter-leg comparisons being significantly different (P ≥ .100). Cohen κ ranged from 0.208 (common femoral) to 0.533 (internal iliac). This study showed that PAD was symmetrically distributed between the 2 legs, with the internal iliac artery being the most symmetric segment. Symmetry of PAD was quantified in 20%.</p>
Follow-up assessment of intracranial aneurysms treated with endovascular coiling: comparison of compressed sensing and parallel imaging time-of-flight magnetic resonance angiography
<p>This file contains the data for the paper "Follow-up assessment of intracranial aneurysms treated with endovascular coiling: comparison of compressed sensing and parallel imaging time-of-flight magnetic resonance angiography"</p>
Ultra-high-resolution functional MR Angiography (fMRA) for detecting vasomotion in humans: pilot data.
<p>Previous version included stimulus conditions with 10-, 15-, 20- and 50-sec stimulus cycle lenghts.<br>This version includes newly acquired conditions with 5-, 6- and 8-sec stimulus cycle lenghts for subject vsmDrivenP1.</p>
VIDEO COLOR OCT ANGIOGRAPHY FOR MYOPIC CHOROIDAL NEOVASCULARIZATION
<p><strong>Purpose: </strong>To investigate the myopic macular neovascularization (mMNV) features on dynamic video-color optical coherence tomography (OCT) angiography (OCTA) and the diagnostic rate versus the static, four-segmentations visualization mode.</p> <p><strong>Design: </strong>Retrospective cohort study PARTICIPANTS: Fifty-four patients with mMNV METHODS: Sixty-two eyes with high myopia complicated by mMNV were included. Clinical charts, fluorescein angiography and structural OCT were used as standard reference to assess lesion activity. Static and video-color OCTA were then analysed and compared by two independent reviewers.</p> <p><strong>Main outcome measures: </strong>Morphology description of mMNV on video-color OCTA and differences in the proportion of diagnosis between video-colour and static OCTA.</p> <p><strong>Results: </strong>62 eyes from 54 patients (mean age 63,22 years) were enrolled. Thirty-four (55%) mMNV were active and 28 (45%) inactive. Twenty-two (65%) active mMNV presented on video-color OCTA as an interlacing vascular network in the outer retina and the choriocapillaris. A tapered form was the prevalent size (72,7%). In 3 eyes (9%) an abnormal and irregular vascular network (AVN) was disclosed and in 5 (15%) only some blood flow alteration. All the lesions extended both in the outer retinal and the choriocapillaris. Eleven (39%) inactive mMNV presented on video-color OCTA as an interlacing vascular network too, in the outer retina and the choriocapillaris. Eight (29%) had some AVN and 6 (21%) only some blood flow alteration. The diagnostic rate of video-color vs static OCTA was 95% (IC 95% 86% to 99%) vs 77% (IC 95% 86% to 99%, p= 0.0009), and shows an advantage in favour of video-colour OCTA of 15% (CI 95%, 3%-27%) and 22% (CI 95%, 7%-38%) in active and inactive lesions, respectively (p<0.026). Lesion extension within both the outer retina and the choriocapillaris was present in 90% and 69% of cases on dynamic OCTA and static OCTA, respectively, with a proportion difference of 20% (CI 95%, 10%-31%, p= 0.0005). Concordance between the two examiners was high: 0.95 (95%, CI 0.88 to 1.00) and 0.96 (0.91 to 1.00) for active and inactive lesions, respectively.</p> <p><strong>Conclusions: </strong>Video color-enhanced OCTA may help in diagnosing mMNV and should be considered by clinicians in addition to structural OCT and static OCTA.</p> <h3>This set of raw data cannot be made publicly availabe as including sensitive information, but might be made available to interested researchers upon reasonable request. Please, forward your request to: dottpaolomilani@hotmail.com</h3>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.