Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
306
datasets available to search
ShareScore release 0.9.0
Dataset results
306 results for “MMS”
Expression Data for HT-1080 cells exposed to ETP, QUE and MMS
GEO Series GSE59368. Homo sapiens. 145 samples. Type: Expression profiling by array.
The assessment of differential expression in the hypothalamus following MMS
GEO Series GSE147375. Mus musculus. 12 samples. Type: Expression profiling by high throughput sequencing.
Wild-type and TP53 genetic knockout BOBSC hiPS cells were maintained in the undifferentiated state or differentiated to definitive endoderm over 72 hours, with or without 5 ppm MMS treatment at 24 hou
GEO Series GSE146225. Homo sapiens. 60 samples. Type: Expression profiling by high throughput sequencing.
Yeast replication in the presence of MMS: WT and isw2 nhp10 strains
GEO Series GSE9122. Saccharomyces cerevisiae. 19 samples. Type: Other.
MMS induced expression changes (Mouse)
GEO Series GSE57789. Mus musculus. 35 samples. Type: Expression profiling by array.
Expression data from yeast with Anc1p or without under basal or MMS exposed conditions
GEO Series GSE12150. Saccharomyces cerevisiae. 12 samples. Type: Expression profiling by array.
YUTO MMS Dataset, Sequence A
Open the record for dataset details and reuse information.
A Clinical Trial to Evaluate the Efficacy of the Morley Medical Sepsis (MMS) Software Device in Predicting Sepsis in Adult Patients Using Artificial Intelligence (AI) Machine Learning Algorithms
ClinicalTrials.gov study NCT04606862. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Multiple Micronutrient Supplementation (MMS) vs IFA Acceptability Crossover Trial
ClinicalTrials.gov study NCT06069856. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Genomewide nucleotide-resolution mapping of single-strand breaks and lesions by GLOE-Seq [MMS treatment]
GEO Series GSE145032. Saccharomyces cerevisiae. 48 samples. Type: Other.
MMS 2 Fast Plasma Investigation, Dual Ion Spectrometer (FPI, DIS) Distribution Moments, Level 2 (L2), Burst Mode, 0.15 s Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually Operates in Slow Survey (SS) Mode outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Results from integrating the standard Moments of Phase Space Distributions formed from the indicated Data Type (DES/DIS Burst, FS or SS). For Convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 2 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Distribution Moments, Level 2 (L2), Fast Mode, 4.5 s Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution are aggregated onboard and made available at Survey (4.5 s) Resolution in this Mode. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually Operates in Slow Survey (SS) Mode outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Results from integrating the standard Moments of Phase Space Distributions formed from the indicated Data Type (DES/DIS Burst, FS or SS). For Convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 4 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Instrument Distributions, Level 2 (L2), Fast Mode, 4.5 s Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution are aggregated onboard and made available at Survey (4.5 s) Resolution in this Mode. This Product contains Phase Space Distribution Maps of Results from surveying the High Resolution Observations during each 4.5 s Period. In particular, the (highest possible Quality at the Time of Release) corrected/converted "Fast Survey Sky Map" Distributions are reported with Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 1 Energetic Particle Detector, Energetic Ion Spectrometer (EPD-EIS) Pulse Height by Time of Flight, Level 2 (L2), Burst Mode, 0.605 s Data
Energetic Particle Detector (EPD), Energetic Ion Spectrometer (EIS) Pulse Height by Time of Flight, Level 2, Burst Survey, 0.605 s Data. The EIS provides ion composition measurements (protons versus oxygen ions) and angular distributions over the energy range from approximately 45 to 500 keV.
MMS 1 Hot Plasma Composition Analyzer (HPCA) Time of Flight, TOF, Counts, Level 2 (L2), Survey Mode, 0.625 s Data
Hot Plasma Composition Analyzer (HPCA) Time of Flight, TOF, Counts, Level 2, Survey 10 s Data. The MMS HPCA instruments measure the energy and composition of magnetospheric plasmas in the energy range from 1 eV to 40 keV. An electrostatic energy analyzer (ESA) that is optically coupled to a carbon-foil based Time-of-Flight (TOF) section comprises each HPCA. The basic HPCA data product is an array of counts for 5 ion species, at 63 energies, for each of 16 elevation anodes. Sixteen basic products, also called azimuths, are acquired every 10 s; half a spacecraft spin period nominally has 16 azimuths. The five ion species are protons (H+), alpha particles (He++), helium ions (He+), singly charged Oxygen (O+), and background counts.
MMS 4 Electron Drift Instrument (EDI) Quality 0 Counts, Level 2 (L2), Burst Mode, 7.8125 ms Data
Electron Drift Instrument (EDI) Q0 Burst Survey, Level 2, 0.0078125 s Data (128 samples/s). EDI has two scientific data acquisition modes, called electric field mode and ambient mode. In electric field mode, two coded electron beams are emitted such that they return to the detectors after one or more gyrations in the ambient magnetic and electric field. The firing directions and times-of-flight allow the derivation of the drift velocity and electric field. In ambient mode, the electron beams are not used. The detectors with their large geometric factors and their ability to adjust the field of view quickly allow continuous sampling of ambient electrons at a selected pitch angle and fixed but selectable energy. To find the beam directions that will hit the detector, EDI sweeps each beam in the plane perpendicular to B at a fixed angular rate of 0.22 °/ms until a signal has been acquired by the detector. Once signal has been acquired, the beams are swept back and forth to stay on target. Beam detection is not determined from the changes in the count-rates directly, but from the square of the beam counts divided by the background counts from ambient electrons, i.e., from the square of the instantaneous signal-to-noise ratio (SNR). This quantity is computed from data provided by the correlator in the Gun-Detector Electronics that also generates the coding pattern imposed on the outgoing beams. If the squared SNR ratio exceeds a threshold, this is taken as evidence that the beam is returning to the detector. The thresholds for SNR are chosen dependent on background fluxes. They represent a compromise between getting false hits (induced by strong variations in background electron fluxes) and missing true beam hits. The basic software loop that controls EDI operations is executed every 2 ms. As the times when the beams hit their detectors are neither synchronized with the telemetry nor equidistant, EDI data have no fixed time-resolution. Data are reported in telemetry slots. In Survey, using the standard packing mode 0, there are eight telemetry slots per second and Gyn Detector Unit (GDU). The last beam detected during the previous slot will be reported in the current slot. If no beam has been detected, the data quality will be set to zero. In Burst telemetry there are 128 slots per second and GDU. The data in each slot consists of information regarding the beam firing directions (stored in the form of analytic gun deflection voltages), times-of-flight (if successfully measured), quality indicators, time stamps of the beam hits, and some auxiliary correlator-related information. Whenever EDI is not in electron drift mode, it uses its ambient electron mode. The mode has the capability to sample at either 90 degrees pitch angle or at 0/180 degrees (field aligned), or to alternate between 90 degrees and field aligned with selectable dwell times. While all options have been demonstrated during the commissioning phase, only the field aligned mode has been used in the routine operations phase. The choices for energy are 250 eV, 500 eV, and 1 keV. The two detectors, which are facing opposite hemispheres, are looking strictly into opposite directions, so while one detector is looking along B the other is looking antiparallel to B (corresponding to pitch angles of 180 and 0 degrees, respectively). The two detectors switch roles every half spin of the spacecraft as the tip of the magnetic field vector spins outside the field of view of one detector and into the field of view of the other detector. These data are a by-product generated from data collected in electric field mode. Whenever no return beam is found in a particular time slot by the flight software to be reported will be flagged with the lowest quality level (quality zero). The ground processing generates a separate data product from these counts data. The EDI instrument paper can be found at: http://link.springer.com/article/10.1007%2Fs11214-015-0182-7. The EDI instrument data products guide can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 2 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Distribution Moments, Level 2 (L2), Burst Mode, 30 ms Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually Operates in Slow Survey (SS) Mode outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Results from integrating the standard Moments of Phase Space Distributions formed from the indicated Data Type (DES/DIS Burst, FS or SS). For Convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 3 Electron Drift Instrument (EDI) Ambient Electron Flux, Projection Method 1 (PM1), Level 2 (L2), Burst Mode, 0.9765625 ms Data
Electron Drift Instrument (EDI) Ambient Burst Survey, Level 2, 0.0009765625 s Data (1024 samples/s). EDI has two scientific data acquisition modes, called electric field mode and ambient mode. In electric field mode, two coded electron beams are emitted such that they return to the detectors after one or more gyrations in the ambient magnetic and electric field. The firing directions and times-of-flight allow the derivation of the drift velocity and electric field. In ambient mode, the electron beams are not used. The detectors with their large geometric factors and their ability to adjust the field of view quickly allow continuous sampling of ambient electrons at a selected pitch angle and fixed but selectable energy. To find the beam directions that will hit the detector, EDI sweeps each beam in the plane perpendicular to B at a fixed angular rate of 0.22 °/ms until a signal has been acquired by the detector. Once signal has been acquired, the beams are swept back and forth to stay on target. Beam detection is not determined from the changes in the count-rates directly, but from the square of the beam counts divided by the background counts from ambient electrons, i.e., from the square of the instantaneous signal-to-noise ratio (SNR). This quantity is computed from data provided by the correlator in the Gun-Detector Electronics that also generates the coding pattern imposed on the outgoing beams. If the squared SNR ratio exceeds a threshold, this is taken as evidence that the beam is returning to the detector. The thresholds for SNR are chosen dependent on background fluxes. They represent a compromise between getting false hits (induced by strong variations in background electron fluxes) and missing true beam hits. The basic software loop that controls EDI operations is executed every 2 ms. As the times when the beams hit their detectors are neither synchronized with the telemetry nor equidistant, EDI data have no fixed time-resolution. Data are reported in telemetry slots. In Survey, using the standard packing mode 0, there are eight telemetry slots per second and Gyn Detector Unit (GDU). The last beam detected during the previous slot will be reported in the current slot. If no beam has been detected, the data quality will be set to zero. In Burst telemetry there are 128 slots per second and GDU. The data in each slot consists of information regarding the beam firing directions (stored in the form of analytic gun deflection voltages), times-of-flight (if successfully measured), quality indicators, time stamps of the beam hits, and some auxiliary correlator-related information. Whenever EDI is not in electron drift mode, it uses its ambient electron mode. The mode has the capability to sample at either 90 degrees pitch angle or at 0/180 degrees (field aligned), or to alternate between 90 degrees and field aligned with selectable dwell times. While all options have been demonstrated during the commissioning phase, only the field aligned mode has been used in the routine operations phase. The choices for energy are 250 eV, 500 eV, and 1 keV. The two detectors, which are facing opposite hemispheres, are looking strictly into opposite directions, so while one detector is looking along B the other is looking antiparallel to B (corresponding to pitch angles of 180 and 0 degrees, respectively). The two detectors switch roles every half spin of the spacecraft as the tip of the magnetic field vector spins outside the field of view of one detector and into the field of view of the other detector. Up until January 4, 2016 the anodes were chosen such that the magnetic field vector projected into the plane of the micro-channel plate entry surface was best aligned with the center of the four anodes ( that is, with the gap between the inner two of the four anodes). Data taken in this configuration are using the term "amb" in the data product names. In the burst data where four channels (corresponding to the four adjacent sensor anode pads) are sampled per GDU, the average (or sum) of the center two channels (channels 2 and 3) represents best the pitch angle of 0 degrees (or 180 degrees). The EDI instrument paper can be found at: http://link.springer.com/article/10.1007%2Fs11214-015-0182-7. The EDI instrument data products guide can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
MMS 2 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Partial Distribution Moments, Level 2 (L2), Burst Mode, 30 ms Data
FPI usually operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution in this Mode. Data are also made available at Survey (4.5 s, etc.) Resolution. Per Mission Design, not all Burst Resolution Data are downlinked, but all Survey Data are downlinked. Planning around Calibration Activities, avoidance of Earth Radiation Belts, etc., when possible, FPI usually operates in Slow Survey (SS) Mode (60 s Resolution) outside of ROI, and then only the 60 s Resolution Survey Data are available. This Product contains Partial Moments that come from performing the Standard Moment Integrals over a limited Portion of Velocity Space. The resulting Quantities are named similarly to their corresponding Standard Moments, but are decorated with 'part' to differentiate. For example, density_part is the Density Moment integrated from a particular Energy Step to Infinity. These Partial Moments are formed from the indicated Data Type (DES/DIS Burst, FS or SS). For convenience, some additional Parameters are included to augment those most commonly found in a Moments Product of this sort, plus Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
MMS 3 Fast Plasma Investigation, Dual Electron Spectrometer (FPI, DES) Instrument Distributions, Level 2 (L2), Fast Mode, 4.5 s Data
The Fast Plasma Instrument (FPI) usually Operates in Fast Survey (FS) Mode in the MMS Region Of Interest (ROI) for the current Mission Phase. Data are taken at Burst (30/150 ms for DES/DIS) Resolution are aggregated onboard and made available at Survey (4.5 s) Resolution in this Mode. This Product contains Phase Space Distribution Maps of Results from surveying the High Resolution Observations during each 4.5 s Period. In particular, the (highest possible Quality at the Time of Release) corrected/converted "Fast Survey Sky Map" Distributions are reported with Time Stamps and other Annotation characterizing the State of the Instrument System at the indicated Time.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.