Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
988
datasets available to search
ShareScore release 0.9.0
Dataset results
988 results for “average”
IBEX High Energy Neutral Atom Imager (Hi) Data Release 16, not Compton-Getting corrected, Survival Probability corrected, Omnidirectional, West Longitude Ecliptic Maps, Level H3 (H3), semiannually averaged Data
* 1: The Interstellar Boundary Explorer (IBEX) has operated in space since 2008 updating our knowledge of the outer heliosphere and its interaction with the local interstellar medium. Start-time: 2008-12-25. There are currently 16 releases of IBEX-HI and/or IBEX-LO data covering 2009-2019.* 2: This data set is from the Release 16 (6 months-cadence) IBEX-Hi map data for the years 2009-2019 in the form of omnidirectional ENA (hydrogen) fluxes with no Compton-Getting correction (nocg) of flux spectra for spacecraft motion and correction for ENA survival probability (sp) between 1 and 100 AU.* 3. The data consist of all-sky maps in Solar Ecliptic Longitude (east and west) and Latitude angles for ENA (hydrogen) fluxes from IBEX-Hi energy bands 2-6 in numerical data form. Energy channels 2-6 have FWHM ranges of 0.52-0.95, 0.84-1.55, 1.36-2.50, 1.99-3.75, 3.13-6.00 keV, respectively. The corresponding center-point energies are 0.71, 1.11, 1.74, 2.73, and 4.29 keV. Details of the data and enabled science from Release 10 are given in the following journal publication:* 4: McComas, D. J., et al. (2017), Seven Years of Imaging the Global Heliosphere with IBEX, Astrophys. J. Supp. Ser., 229(2), 41 (32 pp.),* 5: http://doi.org/10.3847/1538-4365/aa66d8* 6. The following codes are used to define dataset types:- cg = Compton-Getting corrections have been applied to the data to account for the speed of the spacecraft relative to the direction of arrival of the ENAs.- nocg = no Compton-Getting corrections- sp = survival probability corrections have been applied to the data to account for the loss of ENAs due to radiation pressure, photoionization and ionization via charge exchange with solar wind protons as they stream through the heliosphere. This correction scales the data out from IBEX at 1 AU to ~100 AU. In the original data this mode is denoted as Tabular.- noSP - no survival probability corrections have been applied to the data.- omni = data from all directions.- ram = data was collected when the spacecraft was ramming into the incoming ENAs.- antiram = data was collected when the spacecraft was moving away from the incoming ENAs.* 7. The following list associates Release 16 map numbers (1-22) with mission year (1-9), orbits (11-471b), and dates (12/25/2008-12/26/2019):- Map 1: Map2009A, year 1, orbits 11-34, dates 12/25/2008-06/25/2009- Map 2: Map2009B, year 1, orbits 35-58, dates 06/25/2009-12/25/2009- Map 3: Map2010A, year 2, orbits 59-82, dates 12/25/2009-06/26/2010- Map 4: Map2010B, year 2, orbits 83-106, dates 06/26/2010-12/26/2010- Map 5: Map2011A, year 3, orbits 107-130a, dates 12/26/2010-06/25/2011- Map 6: Map2011B, year 3, orbits 130b-150a, dates 06/25/2011-12/24/2011- Map 7: Map2012A, year 4, orbits 150b-170a, dates 12/24/2011-06/22/2012- Map 8: Map2012B, year 4, orbits 170b-190b, dates 06/22/2012-12/26/2012- Map 9: Map2013A, year 5, orbits 191a-210b, dates 12/26/2012-06/26/2013- Map 10: Map2013B, year 5, orbits 211a-230b, dates 06/26/2013-12/26/2013- Map 11: Map2014A, year 6, orbits 231a-250b, dates 12/26/2013-06/26/2014- Map 12: Map2014B, year 6, orbits 251a-270b, dates 06/26/2014-12/24/2014- Map 13: Map2015A, year 7, orbits 271a-290b, dates 12/24/2014-06/24/2015- Map 14: Map2015B, year 7, orbits 291a-310b, dates 06/24/2015-12/23/2015- Map 15: Map2016A, year 8, orbits 311a-330b, dates 12/24/2015-06/23/2016- Map 16: Map2016B, year 8, orbits 331a-351a, dates 06/24/2016-12/26/2016- Map 17: Map2017A, year 9, orbits 351b-371a, dates 12/26/2016-06/24/2017- Map 18: Map2017B, year 9, orbits 371b-391a, dates 06/25/2017-12/25/2017- Map 19: Map2018A, year 10, orbits 391b-411b, dates 12/25/2017-06/28/2018- Map 20: Map2018B, year 10, orbits 412a-431b, dates 06/29/2018-12/26/2018- Map 21: Map2019A, year 11, orbits 432a-451b, dates 12/27/2018-06/27/2019- Map 22: Map2019B, year 11, orbits 452a-471b, dates 06/28/2019-12/26/2019* 8: This particular data set, denoted in the original ascii files as hvset_tabular_NX for N=2009-2019, which indicates a year data collected, and X = A or B, showing first or second half of the year, includes pixel map data from all directions (omnidirectional), no CG, SP, 6 month cadence.
GRNs driving cartilage and bone formation interact via averaging and synergism during cartilage maturation
GEO Series GSE110051. Mus musculus. 9 samples. Type: Expression profiling by high throughput sequencing.
Ensemble averaged signals from the light scattering signals of individual suspension droplets.
<p>The ensemble-averaged light scattering signals were constructed from 1000 individual light scattering signals published on https://doi.org/10.5281/zenodo.6614871</p> <p>The light scattering of the droplets on a Gaussian beam are measured using a commercial device SpraySpy PL100 from AOM-Systems GmbH. It has one laser source with a wavelength of 405nm along with two detectors placed around and named here as A and B. This laser source as well as the two detectors are pointed towards the droplet chain, which is created by a commercial monodisperse droplet generator from FMP Technology GmbH.</p> <p>The detectors, in the form of photo multipliers, aim to track and capture light scattered from the droplets passed through the Gaussian beam. The light scattering signal is subsequently converted into a voltage signal by a transimpedance amplifier. The measuring signal is digitized by a digital oscilloscope PicoScope 6404B. The signal consists of 32 measurement frames with an individual duration of 20ms sampled by 312.5MS/s. Each frame contains about 1000 individual light scattering signals. Since there are two independent detectors with one signal generated by each, there are also two active channels in the measurement on the oscilloscope named correspondingly Channel A and Channel B.</p> <p>In total, measurements are conducted for a concentration range of 0 to 100%. From 0 to 25% a measurement step amounts to 1\% (1%, 2%...,25%) while from 25 to 100\% a measurement step amounts to 2.5%, rounded up to 3% (25%, 28%, 30%...100%).</p>
Average data in two cold and hot seasons
Open the record for dataset details and reuse information.
VOYAGER 1 SOLAR WIND PLS 1 HOUR AVERAGES V1.0
Voyager 1 plasma data of the solar wind, 1 hour averages.
VOYAGER 2 SOLAR WIND PLS 1 HOUR AVERAGES V1.0
Voyager 2 plasma data of the solar wind, 1 hour averages.
VOYAGER 2 SOLAR WIND PLS 1 DAY AVERAGES V1.0
Voyager 2 plasma data of the solar wind, 1 day averages.
VG2 JUP LECP CALIBRATED RESAMPLED SCAN AVERAGED 15MIN V1.1
NULL
Track normalization and averaging of H3K4me3 ChIP-seq data across various cell and tissue types from Mouse ENCODE.
GEO Series GSE73834. Mus musculus. 1 samples. Type: Genome binding/occupancy profiling by high throughput sequencing; Third-party reanalysis.
Track normalization and averaging of epigenetic features across various cell and tissue types derived from Roadmap Epigenomic datasets
GEO Series GSE65050. Homo sapiens. 29 samples. Type: Genome binding/occupancy profiling by high throughput sequencing; Methylation profiling by high throughput sequencing; Third-party reanalysis.
Track normalization and averaging of bislufite-seq DNA methylation data across various cell and tissue types
GEO Series GSE64577. Homo sapiens. 8 samples. Type: Methylation profiling by high throughput sequencing; Third-party reanalysis.
Data set from Ciconte G, Santinelli V, Vicedomini G, Borrelli V, Monasky MM, Micaglio E, Giannelli L, Negro G, Giordano F, Mecarocci V, Mazza BC, Locati E, Anastasia L, Calovic Z, Pappone C. Non-invasive assessment of the arrhythmogenic substrate in Brugada syndrome using signal-averaged electrocardiogram: clinical implications from a prospective clinical trial. Europace. 2019 Dec 1;21(12):1900-1910. doi: 10.1093/europace/euz295. PMID: 31647530.
<p>Data set from Ciconte G, Santinelli V, Vicedomini G, Borrelli V, Monasky MM, Micaglio E, Giannelli L, Negro G, Giordano F, Mecarocci V, Mazza BC, Locati E, Anastasia L, Calovic Z, Pappone C. Non-invasive assessment of the arrhythmogenic substrate in Brugada syndrome using signal-averaged electrocardiogram: clinical implications from a prospective clinical trial. Europace. 2019 Dec 1;21(12):1900-1910. doi: 10.1093/europace/euz295. PMID: 31647530.</p> <p> </p> <p>This is the abstract:</p> <p><strong>Aims: </strong> Brugada syndrome (BrS) represents a major cause of sudden cardiac death in young individuals. The risk stratification to forecast future life-threatening events is still controversial. Non-invasive assessment of late potentials (LPs) has been proposed as a risk stratification tool. However, their nature in BrS is still undetermined. The purpose of this study is to assess the electrophysiological determinants of non-invasive LPs.</p> <p><strong>Methods and results: </strong> Two hundred and fifty consecutive patients with (Group 1, n = 96) and without (Group 2, n = 154) BrS-related symptoms were prospectively enrolled in the registry. Signal-averaged electrocardiogram (SAECG) was performed in all subjects before undergoing epicardial mapping. Group 1 patients exhibited larger arrhythmogenic substrates (AS; 5.8 ± 2.8 vs. 2.6 ± 2.1 cm2, P < 0.001) with more delayed potentials (220.4 ± 46.0 vs. 186.7 ± 42.3 ms, P < 0.001). Late potentials were present in 82/96 (85.4%) Group 1 and in 31/154 (20.1%) Group 2 individuals (P < 0.001). Patients exhibiting LPs had more frequently a spontaneous Type 1 pattern (30.1% vs. 10.9%, P < 0.001), SCN5A mutation (34.5% vs. 21.2%, P = 0.02), and exhibited a larger AS with longer potentials (5.8 ± 2.7 vs. 2.2 ± 1.7 cm2; 231.2 ± 37.3 vs. 213.8 ± 39.0 ms; P < 0.001, respectively). Arrhythmogenic substrate dimension was the strongest predictor of the presence of LPs (odds ratio 1.9; P < 0.001). An AS area of at least 3.5 cm2 identified patients with LPs (area under the curve 0.88, 95% confidence interval 0.843-0.931; P < 0.001) with a sensitivity of 86%, specificity 88%, positive predictive value 85%, and negative predictive value 89%.</p> <p><strong>Conclusion: </strong> The results of this study support the role of the epicardial AS as an electrophysiological determinant of non-invasive LPs, which may serve as a tool in the non-invasive assessment of the BrS substrate, as SAECG-LPs could be considered an expression of the abnormal epicardial electrical activity.</p> <p>ClinicalTrials.gov number (<a href="http://clinicaltrials.gov/show/NCT02641431">NCT02641431</a>; <a href="http://clinicaltrials.gov/show/NCT03106701">NCT03106701</a>).</p> <p> </p>
Monthly and annual climate data averaged from 2011 to 2013 for 79 research plots on the southern slopes of Mt. Kilimanjaro - V 1.0
<p>Annual and monthly means of air temperature, air humidity and precipitation averaged between 2011 and 2013 and based on in situ observations, spatial interpolation and/or statistical modelling for 79 research plots along the southern slopes of Mt. Kilimanjaro.</p> <p>The data set is based on the work of sub-project 1 (Climate Dynamics of the Kilimanjaro Region and Remote Sensing) as part of the DFG research unit 1246 (Kilimanjaro ecosystems under global change). In addition, multi-year rainfall observations from A. Hemp are included (for a detailed description and references, please see the NOTES data file of the data set).</p> <p>For more information on the sub-project, please visit <br /> http://environmentalinformatics-marburg.de/projects/climate-dynamics-of-the-kilimanjaro-region/<br /> <br /> Feel free to contact us via ZENODO or send an e-mail to zenodo@environmentalinformatics-marburg.de</p>
Monthly and annual climate data averaged from 2011 to 2013 for 79 research plots on the southern slopes of Mt. Kilimanjaro - V 1.1
<p>Annual and monthly means of air temperature, air humidity and precipitation averaged between 2011 and 2013 and based on in situ observations, spatial interpolation and/or statistical modelling for 79 research plots along the southern slopes of Mt. Kilimanjaro.</p> <p>The data set is based on the work of sub-project 1 (Climate Dynamics of the Kilimanjaro Region and Remote Sensing) as part of the DFG research unit 1246 (Kilimanjaro ecosystems under global change). In addition, multi-year rainfall observations from A. Hemp are included (for a detailed description and references, please see the NOTES data file of the data set).</p> <p>For more information on the sub-project, please visit <br /> http://environmentalinformatics-marburg.de/projects/climate-dynamics-of-the-kilimanjaro-region/<br /> <br /> Feel free to contact us via ZENODO or send an e-mail to zenodo@environmentalinformatics-marburg.de</p>
Track normalization and averaging of H3K4me3 ChIP-seq data across various cell and tissue types.
GEO Series GSE65049. Homo sapiens. 21 samples. Type: Genome binding/occupancy profiling by high throughput sequencing; Third-party reanalysis.
ACE Electron Proton Alpha Monitor (EPAM) CA60 PHA Sectored Ion SEP Event Accumulated Count Rates, 17 min Averages
Synchronously accumulated rates for the Composition Aperture channels used in the Pulse Height Analyzer matrix data.
Wind Solar Wind Experiment (SWE) Averaged Electron Pitch Angle Distribution (6-12s rate)
Averaged Wind SWE electron pitch angle data (6-12 seconds rate) from an earlier mode (VEIS-era) of the electron instrument. The electron pitch-angle distribution averages included in this data set are derived from integrating the electron pitch-angle distributions measured by the Wind/SWE electron instrument (see Ogilvie et al., "SWE, a comprehensive plasma instrument for the Wind spacecraft", Space Sci. Rev., 71, 55, 1995). Averages of phase-space density (f) over key regions of the unit sphere (the set of all possible electron velocity directions) are computed from 3s measurements which are spaced either 6s or 12s in time. These quantities are reliable and citable with caution, meaning that the PI advises that the user should discuss their interpretations with a member of the SWE science team before publishing. The following comments are intended to aid in the use and interpretation of the averages reported in this data set. We begin this analysis with a measure of f for each pitch-angle bin, six degrees in width, from 0 degrees (flux nearly parallel to B) to 180 degrees (flux nearly anti-parallel with B). The f values for pitch-angles from 0-90 degrees (parallel streaming) are integrated (with angluar weighting and assumptions of gyrotropy) over this half-sphere, then averaged by dividing out the 2-pi solid angle of the half-sphere; the result being referred to as the 'f_para' average. Similarly, the 'f_perp' (flux nearly perpendicular to B) average is the result of integrating f for pitch-angles from 60-120 degrees (a region also 2-pi in solid angle). Next, the 'f_anti' (flux nearly anti-parallel to B) average covers the half-sphere of "backward" streaming electrons; having pitch-angles from 90-180 degrees. Finally, the 'f_omni' (omni-directional) average provides the integral of f over the full sphere, divided by the full 4-pi solid angle; providing a measure of total electron flux into the region of observation. The above analysis is carried out for each of 16 energy channels ranging from about 10 eV to as much as 3 keV. The exact energies at which observations are made is time-varying, and this data set reports the electron speeds each channel observes ( V , in cm/s, along with the observations themselves) at any time. Hence the data set reported here contains: f_para, f_perp, f_anti, f_omni (for each of 16 values of V ), and the 16 values of V (time-varying, although usually much more slowly than the order of a day).
THEMIS-E: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-D: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
ACE Electron Proton Alpha Monitor (EPAM) LEFS150 MFSA, Solar Wind Frame, Sectored Electron Fluxes, Daily Averages
Daily-averaged sectored electron fluxes from the MF Spectrum Analyzer of the ACE/EPAM LEFS150 instrument. All energies thresholds take into account the incident particle type, shielding, and inactive dead-layer of the solid state detector. All fluxes are background corrected and are in the solar wind rest frame.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.