Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
24,887
datasets available to search
ShareScore release 0.9.0
Dataset results
24,887 results for “assessments”
Figure 1 in Hematology and blood biochemistry profile of the freshwater stingray Potamotrygon magdalenae as a tool for population assessment in artificial environments
Figure 1. Different cell types found in peripheral blood of captive adults of Potamotrygon magdalenae.
Figure 2 in Integrative analysis in toxicological assessment of the insecticide Malathion in Allium cepa L. system
Figure 2. Mitotic index at the radicular meristematic region of Allium cepa cells, after exposure for 48 hours to distilled water (H Od – negative control), 0.5 mg mL-1, 1.0 mg mL-1 of Malathion 2 and methyl methanesulfonate (MMS – positive control). KW-H = results of Kruskal-Wallis test and p = value of the statistical probability. Letters on the error bars indicate the result of the statistical Mann-Whitney U test.
Figure 2 in Hematology and blood biochemistry profile of the freshwater stingray Potamotrygon magdalenae as a tool for population assessment in artificial environments
Figure 2. Correlation's matrix test among body condition and physiological parameters in captive adults of Potamotrygon magdalenae. RBC:Erythrocyte count; Hb: Hemoglobin; Ht: Hematocrit; Leu: Leukocte count; Thr: Thrombocyte count; He%: Heterophils proportion; Eos%: Eosinophils proportion; Ly%: Lymphocytes proportion; Mo%: Monocytes proportion; Ure: Urea; Tri: Triglycerides; Pp: Plasma proteins; Sp: Serum proteins; Glu: Glucose; Col: Cholesterol. Ellipses show the type of correlation between each variable, slope shows whether the correlation is positive or negative, color intensity shows the correlation's strength, and amplitude of the ellipse corresponds to the data dispersion. The upper diagonal shows the p values for each correlation.
Movement data set for trust assessment (Drapebot robot cell/Profactor)
<p>In the Drapebot project, a worker collaborates with a large industrial manipulator in two tasks: collaborative transport of carbon fibre patches and collaborative draping. To realize data-driven trust assessement, the worker is equipped with a motion tracking suit and the body movement data is labeled with the trust scores from two standard Trust questionnaire (1. Trust perception scale - HRI, Schaefer 2016; 2. Trust in industrial human robo collaboration, Charalambous, et.al. 2016).</p> <p>For this data set, data has been collected for the draping task from 21 participants all familiar with working with large industrial manipulators. For all sessions, body tracking was performed using the Xsens MVN Awinda tracking suit. It consists of a tight-fitting shirt, gloves, headband, and a series of straps used to attach 17 IMUs to the participant. After calibration the system uses inverse kinematics to track and log the movements of the participant at a rate of 60 Hz. The measurements include linear and angular speed, velocity, and acceleration of every skeleton tracking point (see <a href="https://www.xsens.com/hubfs/Downloads/Manuals/MVN_real-time_network_streaming_protocol_specification.pdf">XSENS manual</a> for a detailed description of avaiable measurements).</p> <p><strong>Data organization</strong></p> <p>There are 21 files for 21 participants. The name of the files is PID01, where the number 01 is the participant. Each file contains all the data that was generated from the XSENS motion capture system. The files are xlsx files and for each sheet inside the excel file there are different types of data:</p> <ul> <li>Segment Orientation - Quat</li> <li>Segment Orientation - Euler</li> <li>Segment Position</li> <li>Segment Velocity</li> <li>Segment Acceleration</li> <li>Segment Angular Velocity</li> <li>Segment Angular Acceleration</li> <li>Joint Angles ZXY</li> <li>Joint Angles XZY</li> <li>Ergonomic Joint Angles ZXY</li> <li>Ergonomic Joint Angles XZY</li> <li>Center of Mass</li> <li>Sensor Free Acceleration</li> <li>Sensor Magnetic Field</li> <li>Sensor Orientation - Quat</li> <li>Sensor Orientation - Euler</li> </ul> <p>See also: <a href="https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US">https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US</a></p> <p>For more information on each specific data and/or sensors please see the xsens manual (Link above)</p> <p><strong>Data Annotation</strong></p> <p>In each .xlsx file the first tab (sheet) is called "Markers". It annotates the starting frame of the individual tasks. The annotations are pickup, draping, return and some files may contain a also a "fail" annotation. Failed attempts should not be taken into consideration for model training.</p> <p>The file trustscores.xlsx includes the results of the trust questionaires for each participant (scores for the individual items as well as the calculated overall trust scores).</p> <p>Items for Trust perception scale - HRI, Schaefer 2016:</p> <ul> <li>Which % of time does the robot <ul> <li>Function successfully</li> <li>Act consistently</li> <li>Communicate with people</li> <li>Provide feedback</li> <li>Malfunction</li> <li>Follow directions</li> <li>Meet the needs of the mission</li> <li>Perform exactly as instructed</li> <li>Have errors</li> </ul> </li> <li>Which % of the time is the robot: <ul> <li>Unresponsive</li> <li>Dependable</li> <li>Reliable</li> <li>Predictable</li> </ul> </li> </ul> <p>Items for Trust in industrial human robo collaboration, Charalambous, et.al. 2016:</p> <ul> <li>The way the robot moved made me uncomfortable</li> <li>I felt I could rely on the robot to do what it was supposed to do </li> <li>The speed at which the gripper picked up and released the components made me uneasy </li> <li>I felt safe interacting with the robot</li> <li>I knew the gripper would not drop the components</li> <li>The size of the robot did not intimidate me</li> <li>The robot gripper did not look reliable</li> <li>I was comfortable the robot would not hurt me</li> <li>I trusted that the robot was safe to cooperate with</li> <li>The gripper seemed like it could be trusted</li> </ul> <p> </p> <p><span>K.</span><span> </span><span>E.</span><span> </span><span>Schaefer,</span><span> </span><span>Measuring</span><span> </span><span>Trust</span><span> </span><span>in</span><span> </span><span>Human</span><span> </span><span>Robot</span><span> </span><span>Interactions: </span><span>Development</span><span> </span><span>of</span><span> </span><span>the</span><span> </span><span>“Trust</span><span> </span><span>Perception</span><span> </span><span>Scale-HRI”</span><span>.</span><span> </span><span>Boston, </span><span>MA:</span><span> </span><span>Springer</span><span> </span><span>US,</span><span> </span><span>2016,</span><span> </span><span>pp.</span><span> </span><span>191–218.</span><span> </span></p> <p><span>G. Charalambous, S. Fletcher, and P. Webb, “The development of </span><span>a scale to evaluate trust in industrial human-robot collaboration,” </span><span>International Journal of Social Robotics</span><span>, vol. 8, pp. 193–209, 2016.</span></p>
Movement data set for trust assessment (Drapebot robot cell/Dallara)
<p>In the Drapebot project, a worker collaborates with a large industrial manipulator in two tasks: collaborative transport of carbon fibre patches and collaborative draping. To realize data-driven trust assessement, the worker is equipped with a motion tracking suit and the body movement data is labeled with the trust scores from two standard Trust questionnaire (1. Trust perception scale - HRI, Schaefer 2016; 2. Trust in industrial human robo collaboration, Charalambous, et.al. 2016).</p> <p>For this data set, data has been collected for the draping task in a near-production setting from 5 participants all familiar with carbon-fibre draping. For all sessions, body tracking was performed using the Xsens MVN Awinda tracking suit. It consists of a tight-fitting shirt, gloves, headband, and a series of straps used to attach 17 IMUs to the participant. After calibration the system uses inverse kinematics to track and log the movements of the participant at a rate of 60 Hz. The measurements include linear and angular speed, velocity, and acceleration of every skeleton tracking point (see <a href="https://www.xsens.com/hubfs/Downloads/Manuals/MVN_real-time_network_streaming_protocol_specification.pdf">XSENS manual</a> for a detailed description of avaiable measurements).</p> <p><strong>Data organization</strong></p> <p>There are 5 files for 5 participants. The name of the files is PID01, where the number 01 is the participant. Each file contains all the data that was generated from the XSENS motion capture system. The files are xlsx files and for each sheet inside the excel file there are different types of data:</p> <ul> <li>Segment Orientation - Quat</li> <li>Segment Orientation - Euler</li> <li>Segment Position</li> <li>Segment Velocity</li> <li>Segment Acceleration</li> <li>Segment Angular Velocity</li> <li>Segment Angular Acceleration</li> <li>Joint Angles ZXY</li> <li>Joint Angles XZY</li> <li>Ergonomic Joint Angles ZXY</li> <li>Ergonomic Joint Angles XZY</li> <li>Center of Mass</li> <li>Sensor Free Acceleration</li> <li>Sensor Magnetic Field</li> <li>Sensor Orientation - Quat</li> <li>Sensor Orientation - Euler</li> </ul> <p>See also: <a href="https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US">https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US</a></p> <p>For more information on each specific data and/or sensors please see the xsens manual (Link above)</p> <p><strong>Data Annotation</strong></p> <p>In each .xlsx file the first tab (sheet) is called "Markers". It annotates the starting frame of the individual tasks. The annotations are pickup, draping, return and some files may contain a also a "fail" annotation. Failed attempts should not be taken into consideration for model training.</p> <p>The file trustscores.xlsx includes the results of the trust questionaires for each participant (scores for the individual items as well as the calculated overall trust scores).</p> <p>Items for Trust perception scale - HRI, Schaefer 2016:</p> <ul> <li>Which % of time does the robot <ul> <li>Function successfully</li> <li>Act consistently</li> <li>Communicate with people</li> <li>Provide feedback</li> <li>Malfunction</li> <li>Follow directions</li> <li>Meet the needs of the mission</li> <li>Perform exactly as instructed</li> <li>Have errors</li> </ul> </li> <li>Which % of the time is the robot: <ul> <li>Unresponsive</li> <li>Dependable</li> <li>Reliable</li> <li>Predictable</li> </ul> </li> </ul> <p>Items for Trust in industrial human robo collaboration, Charalambous, et.al. 2016:</p> <ul> <li>The way the robot moved made me uncomfortable</li> <li>I felt I could rely on the robot to do what it was supposed to do </li> <li>The speed at which the gripper picked up and released the components made me uneasy </li> <li>I felt safe interacting with the robot</li> <li>I knew the gripper would not drop the components</li> <li>The size of the robot did not intimidate me</li> <li>The robot gripper did not look reliable</li> <li>I was comfortable the robot would not hurt me</li> <li>I trusted that the robot was safe to cooperate with</li> <li>The gripper seemed like it could be trusted</li> </ul> <p> </p> <p>K. E. Schaefer, Measuring Trust in Human Robot Interactions: Development of the “Trust Perception Scale-HRI”. Boston, MA: Springer US, 2016, pp. 191–218.</p> <p>G. Charalambous, S. Fletcher, and P. Webb, “The development of a scale to evaluate trust in industrial human-robot collaboration,” International Journal of Social Robotics, vol. 8, pp. 193–209, 2016.</p>
Movement data set for trust assessment (Drapebot robot cell/DLR)
<p>In the Drapebot project, a worker collaborates with a large industrial manipulator in two tasks: collaborative transport of carbon fibre patches and collaborative draping. To realize data-driven trust assessement, the worker is equipped with a motion tracking suit and the body movement data is labeled with the trust scores from two standard Trust questionnaire (1. Trust perception scale - HRI, Schaefer 2016; 2. Trust in industrial human robo collaboration, Charalambous, et.al. 2016).</p> <p>For this data set, data has been collected for the draping task from 21 participants all familiar with working with large industrial manipulators. For all sessions, body tracking was performed using the Xsens MVN Awinda tracking suit. It consists of a tight-fitting shirt, gloves, headband, and a series of straps used to attach 17 IMUs to the participant. After calibration the system uses inverse kinematics to track and log the movements of the participant at a rate of 60 Hz. The measurements include linear and angular speed, velocity, and acceleration of every skeleton tracking point (see <a href="https://www.xsens.com/hubfs/Downloads/Manuals/MVN_real-time_network_streaming_protocol_specification.pdf">XSENS manual</a> for a detailed description of avaiable measurements).</p> <p><strong>Data organization</strong></p> <p>There are 21 files for 21 participants. The name of the files is PID01, where the number 01 is the participant. Each file contains all the data that was generated from the XSENS motion capture system. The files are xlsx files and for each sheet inside the excel file there are different types of data:</p> <ul> <li>Segment Orientation - Quat</li> <li>Segment Orientation - Euler</li> <li>Segment Position</li> <li>Segment Velocity</li> <li>Segment Acceleration</li> <li>Segment Angular Velocity</li> <li>Segment Angular Acceleration</li> <li>Joint Angles ZXY</li> <li>Joint Angles XZY</li> <li>Ergonomic Joint Angles ZXY</li> <li>Ergonomic Joint Angles XZY</li> <li>Center of Mass</li> <li>Sensor Free Acceleration</li> <li>Sensor Magnetic Field</li> <li>Sensor Orientation - Quat</li> <li>Sensor Orientation - Euler</li> </ul> <p>See also: <a href="https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US">https://base.movella.com/s/article/Output-Parameters-in-MVN-1611927767477?language=en_US</a></p> <p>For more information on each specific data and/or sensors please see the xsens manual (Link above)</p> <p><strong>Data Annotation</strong></p> <p>In each .xlsx file the first tab (sheet) is called "Markers". It annotates the starting frame of the individual tasks. The annotations are pickup, draping, return and some files may contain a also a "fail" annotation. Failed attempts should not be taken into consideration for model training.</p> <p>The file trustscores.xlsx includes the results of the trust questionaires for each participant (scores for the individual items as well as the calculated overall trust scores).</p> <p>Items for Trust perception scale - HRI, Schaefer 2016:</p> <ul> <li>Which % of time does the robot <ul> <li>Function successfully</li> <li>Act consistently</li> <li>Communicate with people</li> <li>Provide feedback</li> <li>Malfunction</li> <li>Follow directions</li> <li>Meet the needs of the mission</li> <li>Perform exactly as instructed</li> <li>Have errors</li> </ul> </li> <li>Which % of the time is the robot: <ul> <li>Unresponsive</li> <li>Dependable</li> <li>Reliable</li> <li>Predictable</li> </ul> </li> </ul> <p>Items for Trust in industrial human robo collaboration, Charalambous, et.al. 2016:</p> <ul> <li>The way the robot moved made me uncomfortable</li> <li>I felt I could rely on the robot to do what it was supposed to do </li> <li>The speed at which the gripper picked up and released the components made me uneasy </li> <li>I felt safe interacting with the robot</li> <li>I knew the gripper would not drop the components</li> <li>The size of the robot did not intimidate me</li> <li>The robot gripper did not look reliable</li> <li>I was comfortable the robot would not hurt me</li> <li>I trusted that the robot was safe to cooperate with</li> <li>The gripper seemed like it could be trusted</li> </ul> <p> </p> <p>K. E. Schaefer, Measuring Trust in Human Robot Interactions: Development of the “Trust Perception Scale-HRI”. Boston, MA: Springer US, 2016, pp. 191–218.</p> <p>G. Charalambous, S. Fletcher, and P. Webb, “The development of a scale to evaluate trust in industrial human-robot collaboration,” International Journal of Social Robotics, vol. 8, pp. 193–209, 2016.</p>
Fig. 3 in Assessing genetic diversity of three species of potato tuber moths (Gelechiidae, Lepidoptera) in the Ecuadorian highlands
Fig. 3. Distribution of 5 haplotypes and sequence identity between each pair of Symmetrischema tangolias haplotypes. St-H1 was present in all 4 provinces; St-H2 was present in 3 provinces; the other 3 haplotypes were present only in 1 province for each haplotype. Arrows point to province(s) instead of a specific sampling location.
Fig. 1 in Assessing genetic diversity of three species of potato tuber moths (Gelechiidae, Lepidoptera) in the Ecuadorian highlands
Fig. 1. Use of pheromone traps to collect potato tuber moths in Cacha, Chimborazo, and Tishinguirí, Bolívar: (A) potato crops are grown in mountainous regions of Ecuador where smallholder terrace farming is predominant; (B) low-cost pheromone traps were made of plastic bottles; a species-specific lure is fixed to the bottle cap using a string, and thumb-sized holes were carved to allow moths to fly into the bottle that was filled with soapy water; (C) 3 different traps were placed (pointed by arrows) in each field at least 100 m apart to catch different moths.
Fig. 5 in Assessing genetic diversity of three species of potato tuber moths (Gelechiidae, Lepidoptera) in the Ecuadorian highlands
Fig. 5. Distribution of 3 haplotypes and sequence identity between each pair of Phthorimaea operculella haplotypes. Po-H1 was present in all 4 provinces, Po-H3 was present only in Cotopaxi and Chimborazo; Po-H2 was limited to Tungurahua.
Fig. 2 in Assessing genetic diversity of three species of potato tuber moths (Gelechiidae, Lepidoptera) in the Ecuadorian highlands
Fig. 2. Alignment of 5 COI haplotype sequences of Symmetrischema tangolias samples. KX443104.1 is a reference sequence from GenBank. Sequences of these 5 haplotypes were deposited in GenBank with accession numbers MN223391 to MN223395.
Fig. 4 in Assessing genetic diversity of three species of potato tuber moths (Gelechiidae, Lepidoptera) in the Ecuadorian highlands
Fig. 4. Alignment of 3 unique COI haplotype sequences of Phthorimaea operculella. MF121882 is a reference sequence from GenBank. Sequences of these 3 haplotypes were deposited in GenBank with accession numbers MN205567 to MN205569.
Dataset for 'The State of Data Curation at NeurIPS: An Assessment of Dataset Development Practices in the Datasets and Benchmarks Track'
<p>This packages comprises of analyses and evaluations of 60 datasets from the NeurIPS Datasets and Benchmarks track. It is part of a paper currently under review at the 2024 the NeurIPS Datasets and Benchmarks track, titled, "The State of Data Curation at NeurIPS: An Assessment of Dataset Development Practices in the Datasets and Benchmarks Track". </p>
Assessing Hydrodynamic resistance in Microfluidics: A Case Study - datasets
<p><strong><span>Abstract: </span></strong><span>Hydrodynamic resistance is a critical parameter in microfluidics, affecting device functionality and performance.</span><span> However, quantifying hydrodynamic resistance in microfluidics is a challenge due to many influencing factors and the difficulties associated with the precise measurements of low flow rates (< 10 </span><span><span>m</span></span><span>L/min) and pressure drops (< 5 kPa). This article presents a simple experimental test method for assessing hydrodynamic resistance, correlating with theoretical and numerical calculations. The results demonstrate good agreement between benchtop and theoretical data, suggesting a potential standardized method for assessing hydrodynamic resistance in microfluidic devices.</span></p> <p> </p> <p><span>In the files attached: Dataset</span></p> <p> </p> <p><strong><span>Funding:</span></strong><span> This project (20NMR02 MFMET) has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme. V.S. would like to acknowledge the FCT, I.P., for funding of the Research Unit INESC MN (UID/05367/2020) through pluriannual BASE and PROGRAMATICO and project LA/P/0140/2020 of the Associate Laboratory Institute for Health and Bioeconomy – i4HB</span></p>
Fig 2 in Monitoring and assessing the physico-chemical water properties and planktonic communities in tilapia nursing pond
Fig 2: Percentages of different phytoplankton communities during the study period (a, b c, are indicating the size category as small, medium and large)
Fig 1 in Monitoring and assessing the physico-chemical water properties and planktonic communities in tilapia nursing pond
Fig 1: Percentages of total phytoplankton and total zooplankton in all size categorized pond during the sampling period
Fig 1A in Toxicological assessments of basic blue 3 dye in fresh water bivalve Lamellidens marginalis
Fig 1A: Section passing through gill of fresh water bivalve Lamellidensmarginalisfrom control group (400X). B: Effect of 40 ppm (LC0) of Basic Blue 3 on gill of fresh water bivalve Lamellidensmarginalis after 96 hours exposure (400X) C: Effect of 70 ppm (LC50) of Basic Blue 3 on gill of fresh water bivalve Lamellidenmarginalis after 96 hours exposure (400X)
Fig 2A in Toxicological assessments of basic blue 3 dye in fresh water bivalve Lamellidens marginalis
Fig 2A: Section passing through hepatopancreas of fresh water bivalve Lamellidens marginalis from control group (400X). B: Effect of 40 ppm (LC0) of Basic Blue 3 on hepatopancreas of fresh water bivalve Lamellidens marginalis after 96 hours exposure (400X) C: Effect of 70 ppm (LC50) of Basic Blue 3 on hepatopancreas of fresh water bivalve Lamellidens marginalis after 96 hours exposure (400X)
Fig 4A in Toxicological assessments of basic blue 3 dye in fresh water bivalve Lamellidens marginalis
Fig 4A: Photomicrogragh of gill cell of Lamellidens marginalis for 96 hours exposure; degree of damage class 0 B: Photomicrogragh of gill cell of Lamellidens marginalis for 96 hours exposure to 40 ppm concentration of Basic blue 3; degree of damage class 0 C: Photomicrogragh of gill cell of Lamellidens marginalis for 96 hours exposure to 70 ppm concentration of Basic blue 3; degree of damage class I
Fig. 8 in Assessing the quality of biogeochemical coastal data: a step-wise procedure Abstract
Fig. 8: Percentage of assigned quality flags for a) temperature and salinity, b) nutrients and c) chlorophyll a in the LTER-MC dataset grouped by period, following the simplified QF scheme.
Fig. 4 in Assessing the quality of biogeochemical coastal data: a step-wise procedure Abstract
Fig. 4: A) Schematic representation of a possible spike (V2) evaluated based on its previous (V1) and subsequent (V3) values of the profile. B) Examples of identified spikes in nitrate profiles at low (pMC 535, -5 m), medium (●M276, -5m) and high (○MC48, -2 m) concentrations. Spikes are in orange.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.