Skip to main content
ConductScienceScienceDex
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

614

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

614 results for “Impedance”

Learn how ShareScore rates datasets ↗
dryad32/100

Data from: Transmural impedance detects graded changes of inflammation in experimental colitis

<p>Ulcerative colitis is a chronic disease in which the mucosa of the colon or rectum becomes inflamed. An objective biomarker of inflammation will provide quantitative measures to support qualitative assessment during an endoscopic examination. Previous studies show that transmural electrical impedance is a quantifiable biomarker of inflammation. Here we hypothesise that impedance detects spatially restricted areas of inflammation, thereby allowing the distinction between regions that differ in their severity of inflammation. A platinum ball electrode (3.2 mm² surface area) was placed into normal or 2,4,6-trinitrobenzene sulfonic acid (TNBS) inflamed colonic regions of rats and impedance measurements obtained by passing current between the intraluminal and a large subcutaneous return electrode. Histology of the colon was correlated with impedance measurements. The impedance of normal tissue was 1.6-1.8 kOhms. Following TNBS injection, impedance significantly decreased within the inflammatory penumbra (<i>P</i> &lt; 0.05), and decreased more in the inflammatory epicentre (<i>P</i> = 0.02). Histological damage correlated with impedance values (<i>P </i>&lt; 0.05). Thus, impedance values of 1.6-1.8 kOhms, 1.3-1.4 kOhms and 1.0 – 1.1 kOhms were predictors of normal, mildly inflamed and moderately inflamed tissue, respectively. In conclusion, transmural impedance is a real-time, <i>in vivo </i>biomarker of mucosal integrity, and distinguishes between severities of intestinal inflammation.</p>

opencc-zeroFeb 2020View details →
zenodo32/100

Dataset for the paper "A catalyst layer optimisation approach using electrochemical impedance spectroscopy for PEM fuel cells operated with pyrolysed transition metal-N-C catalysts", J Power Sources, 2016, DOI: 10.1016/j.jpowsour.2016.05.035

<p>Data file for paper:&quot;A catalyst layer optimisation approach using electrochemical impedance spectroscopy for PEM fuel cells operated with pyrolysed transition metal-N-C catalysts&quot;</p> <p>Daniel Malko, Thiago Lopes, Edson A. Ticianelli, Anthony Kucernak</p> <p>Journal of Power Sources, 2016</p> <p>DOI: 10.1016/j.jpowsour.2016.05.035</p> <p>Please cite the above paper if you use this data</p>

opencc-zeroMay 2016View details →
zenodo32/100

Effects of individualized Electrical Impedance Tomography and image reconstruction settings upon the assessment of regional ventilation distribution: Comparison to 4-dimensional Computed Tomography in a porcine model

<p>Reconstruction Models used for identification of optimal settings for comparison to CT images. Forward models are available in the supplement of the article but were removed form the inverse models due to redundance storage within each model.</p> <p>Prior reconstruction in EIDORS, forward models have to be added again to<em> imdl.fwd_model</em> and <em>imdl.jacobian_background.fwd_model</em>.</p>

opencc-by-4.0May 2017View details →
dryad32/100

Data from: Improper data practices erode the quality of global ecological databases and impede the progress of ecological research

<p>The scientific community has entered an era of big data. However, with big data comes big responsibilities, and best practices for how data are contributed to databases have not kept pace with the collection, aggregation, and analysis of big data. Here, we rigorously assess the quantity of data for specific leaf area (SLA) available within the largest and most frequently used global plant trait database, the TRY Plant Trait Database, exploring how much of the data were <em>applicable </em>(i.e., original, representative, logical, and comparable) and <em>traceable </em>(i.e., published, cited, and consistent). Over three-quarters of the SLA data in TRY either lacked applicability or traceability, leaving only 22.9% of the original data usable compared to the 64.9% typically deemed usable by standard data cleaning protocols. The remaining usable data differed markedly from the original for many species, which led to altered interpretation of ecological analyses. Though the data we consider here make up only 4.5% of SLA data within TRY, similar issues of <em>applicability </em>and <em>traceability </em>likely apply to SLA data for other species as well as other commonly measured, uploaded, and downloaded plant traits. We end with suggested steps forward for global ecological databases, including suggestions for both uploaders to and curators of databases with the hope that, through addressing the issues raised here, we can increase data quality and integrity within the ecological community.</p>

opencc-zeroJan 2024View details →
zenodo32/100

State of Health Estimation of Lithium-Ion Batteries Based on Electrochemical Impedance Spectroscopy and Backpropagation Neural Network

Open the record for dataset details and reuse information.

opencc-by-4.0Sep 2021View details →
zenodo32/100

Addendum to "Comprehensive battery aging dataset: capacity and impedance fade measurements of a lithium-ion NMC/C-SiO cell [dataset]"

<p>This is an addendum to the previously published dataset with the title "Comprehensive battery aging dataset: capacity and impedance fade measurements of a lithium-ion NMC/C-SiO cell [dataset]" (DOI: 10.35097/1947).<br>In the previous publication, the "cell_eisv2.zip" file was incomplete and only contained data for cells P001_1 to P044_2.<br>The fixed "cell_eisv2_fixed.zip" file of this addendum contains data for all 228 cells P001_1 to P076_3.</p>

opencc-by-4.0Dec 2023View details →
zenodo32/100

Comprehensive battery aging dataset: capacity and impedance fade measurements of a lithium-ion NMC/C-SiO cell [dataset]

<p>Battery degradation is critical to the cost-effectiveness and usability of battery-powered products. Aging studies can help to better understand and model degradation and to optimize the operation strategy. Nevertheless, there are only a few comprehensive and freely available aging datasets for these applications.<br>To our knowledge, the dataset presented in the following is one of the largest published to date. It contains over 3 billion data points from 228 commercial NMC/C+SiO lithium-ion cells aged for more than a year under a wide range of operating conditions. We investigate calendar and cyclic aging and also apply different driving cycles to some of the cells. The dataset includes result data (such as the remaining usable capacity or impedance measured in check-ups) and raw data (i.e., measurement logs with two-second resolution).<br>The data can be used in a wide range of applications, for example, to model battery degradation, gain insight into lithium plating, optimize operation strategies, or test battery impedance or state estimation algorithms using machine learning or Kalman filtering.</p>

opencc-by-4.0Dec 2023View details →
dryad32/100

ESM of determination of transdermal rate of metallic microneedle array through impedance measurements-based numerical check screening algorithm

<p>Microneedle systems have been widely used in health monitoring, painless drug delivery, and medical cosmetology. Although many studies on microneedle materials, structures, and applications have been conducted, the applications of microneedles often suffered from issues of inconsistent penetration rates due to the complication of skin-microneedle interface. In this study, we demonstrated a methodology of determination of transdermal rate of metallic microneedle array through impedance measurements-based numerical check screening algorithm. Metallic sheet microneedle array sensors with different sizes were fabricated to evaluate different transdermal rates. In vitro sensing of hydrogen peroxide confirmed the effect of transdermal rate on the sensing outcomes. A FEM simulation model of a microneedle array revealed the monotonous relation between the transdermal state and test current. Accordingly, two methods were first derived to calculate the transdermal rate from the test current. First, an exact logic method provided the number of unpenetrated tips per sheet, but it required more rigorous testing results. Second, a fuzzy logic method provided an approximate transdermal rate on adjacent areas, being more applicable and robust to errors. Real-time transdermal rate estimation may be essential for improving the performance of microneedle systems, and this study provides various fundaments toward that goal.</p>

opencc-zeroJan 2022View details →
dryad32/100

Data from: Validity of bioelectrical impedance analysis in predicting total body water and adiposity among Senegalese school-aged children

Introduction: Childhood obesity is currently a serious public health challenge in developing countries. Therefore, an accurate assessment of adiposity is required. The objective of this study was to validate BIA prediction equations for the assessment of total body water and adiposity or percentage of body fat for the first time in Senegalese school-aged children. Methods: One-hundred-fifty-one (151) pupils who were 8-11 years old were randomly selected from four public schools in Dakar. The body composition measured by deuterium dilution method (DDM) was used as the reference method and compared to that predicted by BIA using a multi-frequency analyser. Stepwise backward multiple linear regression was performed to calculate TBW and %BF in a subsample, which were then validated it in the rest of the sample. The Bland and Altman approach was used to assess the agreement between the two methods (bias and limits of agreement). Results: FFM was higher in boys (24.6±6.9 kg) compared to girls (21.2±3.3 kg; P&lt;0.001), and %BF was lower in boys (5.1±4.6 kg) compared to girls (5.3±3.8 kg; P&lt;0.05). Overall, 11.3% of children were obese (%BF ≥25% in boys, and ≥30% in girls) and 4.6% were overweight/obese according to their BMI-z score (&gt;+1). The equations developed were as follows: TBW=0.376(Height²/Z50)-0.470 (sex) +0.076(weight) +0.065(height)-2.28. %BF= -1.10(height²/Z50) +3.14(sex)+1.57(weight)-4.347. These specific equations showed good precision and a low and non-significant mean bias (0.11 kg, P=0.279; and 0.19 kg, P=0.764) for TBW and %BF, respectively. Conclusion: The newly developed equations can be used as an accurate and alternative tool for screening for obesity among African school-aged children in various settings

opencc-zeroDec 2017View details →
zenodo32/100

Open Extensive 3D Dataset of Geometric Objects Placed in a Watertank for Electrical Impedance Tomography

<p>Electrical impedance tomography (EIT) is a non-invasive, radiation-free imaging method for visualizing the tomography&nbsp;of electrically conductive objects. The image reconstruction approach using data-driven methods or deep neural networks&nbsp;(DNN) has become very popular. To train such a reconstruction network, much data is required to reconstruct the conductivity distribution reliably, which is why simulation data are often used. This is an open-access experimental 3D EIT&nbsp;data set. The measurements were generated using the Sciospec EIT device, from which 64 electrodes were connected in two stages, with 32 electrodes, to&nbsp;a phantom tank filled with saline. Various ball objects of different sizes and materials were placed in this tank volume-wide.&nbsp;The provided dataset contains more than 124,000 samples.</p>

opencc-by-4.0Jun 2024View details →
zenodo32/100

Dataset from the study: "Brain Haemorrhage Detection using a SVM Classifier with Electrical Impedance Tomography Measurement Frames"

<p>This repository contains the scripts and other resources used in:</p> <p>&ldquo;Brain Haemorrhage Detection using a SVM Classifier with Electrical Impedance Tomography Measurement Frames&rdquo;, McDermott B et al. 10.1371/journal.pone.0200469</p> <p>&nbsp;</p> <p>&gt;&gt; THIS DATA IS FREE FOR USE IN ANY SCIENTIFIC RESEARCH WITH CITATION (PLEASE USE THE DOI FOR PRECISE CITATION): DOI 10.1371/journal.pone.0200469</p> <p>&nbsp;</p> <p>&gt;&gt; IF YOU USE THESE RESOURCES, CITE!!!</p> <p>&nbsp;</p> <p>The repository contains the code and resources to generate the EIT Measurement Frames used in Numerical Models (STL models, code to mesh, code to generate frames)</p> <p>&nbsp;</p> <p>Also included are the Measurement Frames generated from the Phantom Studies.</p> <p>&nbsp;</p> <p><strong>=&gt; This is all the data (how to replicate it for numerical studies and the actual data for the phantom part) used in the study</strong></p> <p>&nbsp;</p> <p>Classifier generation, training, testing, cross validation etc uses standard MATLAB methods and resources: fitcsvm() etc.</p> <p>&nbsp;</p> <p>The subfolders are ordered numerically in the logical order of use</p> <p>The subfolders contain text files with more details and description relevant to the contents of the respective subfolder.</p> <p>&nbsp;</p> <p>Note:</p> <p>&nbsp;</p> <p>Software used in this study:</p> <p>At a minimum the first 2 will be needed to be installed on your computer</p> <p>(other methods etc needed are detailed within the folders)</p> <p>&nbsp;</p> <p><strong>MATLAB 2017B</strong> (<a href="https://uk.mathworks.com/products/matlab.html">https://uk.mathworks.com/products/matlab.html</a>):</p> <p>The primary software tool used throughout</p> <p>&nbsp;</p> <p><strong>EIDORS </strong>(<a href="http://eidors3d.sourceforge.net/index.shtml">http://eidors3d.sourceforge.net/index.shtml</a>)<strong>:&nbsp;</strong></p> <p>Open Source software package, compatible with MATLAB, with tools for use in Electrical Impedance Tomography studies.</p> <p>&nbsp;</p> <p><strong>Autodesk Fusion 360</strong> (<a href="https://www.autodesk.com/products/fusion-360/overview?mktvar002=685209&amp;mkwid=sMHGuhLcc%7Cpcrid%7C209188650131%7Cpkw%7Cfusion%20360%7Cpmt%7Ce%7Cpdv%7Cc%7Cslid%7C%7Cpgrid%7C34851227038%7Cptaid%7Ckwd-11029869505%7C&amp;intent=&amp;utm_medium=cpc&amp;utm_source=google&amp;utm_campaign=GGL_Fusion+360_IE_BR_SEM&amp;utm_term=fusion%20360&amp;utm_content=sMHGuhLcc%7Cpcrid%7C209188650131%7Cpkw%7Cfusion%20360%7Cpmt%7Ce%7Cpdv%7Cc%7Cslid%7C%7Cpgrid%7C34851227038%7Cptaid%7Ckwd-11029869505%7C&amp;gclid=Cj0KCQjw1NzZBRCoARIsAIaMwut5zqUE_d7oieOvw6H3SpU45Jw7vwL5KAKqyRYW20Be6QWE-V3HaB0aAnW0EALw_wcB">https://www.autodesk.com/products/fusion-360/overview?mktvar002=685209&amp;mkwid=sMHGuhLcc|pcrid|209188650131|pkw|fusion%20360|pmt|e|pdv|c|slid||pgrid|34851227038|ptaid|kwd-11029869505|&amp;intent=&amp;utm_medium=cpc&amp;utm_source=google&amp;utm_campaign=GGL_Fusion+360_IE_BR_SEM&amp;utm_term=fusion%20360&amp;utm_content=sMHGuhLcc|pcrid|209188650131|pkw|fusion%20360|pmt|e|pdv|c|slid||pgrid|34851227038|ptaid|kwd-11029869505|&amp;gclid=Cj0KCQjw1NzZBRCoARIsAIaMwut5zqUE_d7oieOvw6H3SpU45Jw7vwL5KAKqyRYW20Be6QWE-V3HaB0aAnW0EALw_wcB</a>):</p> <p>Used to generate the head, brain and lesion STL files. These final STL files are provided in this repository.</p>

opencc-by-4.0Jun 2018View details →
zenodo32/100

Neonate head mesh for Electrical Impedance Tomography - coarse

<p>A head mesh for EIT made by&nbsp;https://github.com/EIT-team/Mesher for&nbsp;https://github.com/EIT-team/PEITS.</p> <p>This archive is used for Travis CI</p>

opencc-by-4.0Jul 2018View details →
zenodo32/100

Dataset for: Ultrafast Signatures of Merocyanine Overcoming Steric Impedance in Crystalline Spyiropyran

<p>Data underlying the results from femtosecond spectroscopy and UED studies of spiropyran crystals.&nbsp;</p>

opencc-by-4.0Oct 2024View details →
zenodo32/100

The role of local impedance drop in the acute lesion efficacy during pulmonary vein isolation performed with a new contact force sensing catheter – a pilot study

<p>The role of local impedance drop in the acute lesion efficacy during pulmonary vein isolation performed with a new contact force sensing catheter &ndash; a pilot study</p>

opencc-by-4.0Jul 2021View details →
zenodo32/100

Supplementary Material for: 'An impedance pneumography signal quality index: design, assessment and application to respiratory rate monitoring'

<p>This supplementary material accompanies:</p> <p>Charlton P.H. <em>et al.</em>,&nbsp;&quot;<a href="https://doi.org/10.1016/j.bspc.2020.102339">An impedance pneumography signal&nbsp;quality index for respiratory rate monitoring: design,&nbsp;assessment and application</a>&quot;, <em>Biomedical Signal Processing and Control</em>,&nbsp;65, 102339, 2021.</p> <p>The Impedance Pneumography Signal Quality Index (SQI) dataset and accompanying scripts (in Matlab format)&nbsp;are provided to facilitate reproduction of&nbsp;the analyses using data from the MIMIC III dataset in this&nbsp;publication.</p> <p><strong>Summary of Publication</strong></p> <p>In this article we developed and assessed the performance of a signal quality index (SQI) for the impedance pneumography signal.<br> The SQI was developed using data from the <a href="http://peterhcharlton.github.io/RRest/listen_dataset.html">Listen dataset</a>, and assessed using data from the <a href="http://peterhcharlton.github.io/RRest/listen_dataset.html">Listen dataset</a>&nbsp;and MIMIC III&nbsp;datasets.<br> The SQI was found to accurately classify segments of impedance pneumography signal as either high or low quality. Furthermore, when it was coupled with a high performance RR algorithm, highly accurate and precise RRs were estimated from those segments deemed to be high quality.&nbsp;In this study performance was assessed in the critical care environment - further work is required to deteremine whether the SQI is suitable for use with wearable sensors.&nbsp;Both the dataset and code used to perform this study are publicly available.</p> <p><strong>Reproducing this Publication</strong></p> <p>The work relating to the MIMIC dataset in this publication can be reproduced as follows:</p> <p><strong>&nbsp;- Reproducing the analysis</strong><br> These steps can be used to quickly reproduce the analysis using the curated and annotated dataset.</p> <p>* &nbsp; Download the curated and annotated dataset from <a href="https://doi.org/10.5281/zenodo.3973770">Zenodo</a>&nbsp;using this <a href="https://zenodo.org/record/3973771/files/mimic_imp_sqi_data.mat?download=1">direct download link</a>.<br> * &nbsp; Run the analysis using the <a href="https://zenodo.org/record/3973771/files/run_imp_sqi_mimic.m?download=1"><em>run_imp_sqi_mimic.m</em></a>&nbsp;script.</p> <p><strong>&nbsp;- Full reproduction</strong><br> These steps include downloading the raw data files, extracting data from these files, collating the dataset, manually annotating the data, and performing the analysis.</p> <p>* &nbsp; Use the <a href="https://zenodo.org/record/3973771/files/ImP_SQI_mimic_data_importer.m?download=1"><em>ImP_SQI_mimic_data_importer.m</em></a>&nbsp;script to download raw MIMIC data files from PhysioNet, and collate them into a single Matlab file.<br> * &nbsp; Prepare the dataset for manual annotation by running the <a href="https://zenodo.org/record/3973771/files/run_imp_sqi_mimic.m?download=1"><em>run_imp_sqi_mimic.m</em></a>&nbsp;script.<br> * &nbsp; Manually annotate the signals by running the <a href="https://zenodo.org/record/3973771/files/run_imp_sqi_mimic.m?download=1"><em>run_mimic_imp_annotation.m</em></a>&nbsp;script - the annotations are stored in separate files (the original annotation files are available <a href="https://zenodo.org/record/3974113/files/2019_annotations.zip?download=1">here</a>).<br> * &nbsp; Import the manual annotations into the collated data file by re-running the <a href="https://zenodo.org/record/3973771/files/ImP_SQI_mimic_data_importer.m?download=1"><em>ImP_SQI_mimic_data_importer.m</em></a>&nbsp;script.<br> * &nbsp; Run <a href="https://zenodo.org/record/3973771/files/run_imp_sqi_mimic.m?download=1"><em>run_imp_sqi_mimic.m</em></a>&nbsp;to perform the analysis described in the publication.</p> <p><strong>&nbsp;- Submitted manuscript</strong></p> <p>The submitted manuscript is available <a href="https://zenodo.org/record/5211463/files/Impedance%20SQI%20manuscript%20-%20Oct%202020%20revision.docx?download=1">here</a>.</p> <p>The scripts are also stored (alongside details of how to use them) are available in the <a href="http://peterhcharlton.github.io/RRest/">RRest GitHub repository</a> at:&nbsp;<a href="https://github.com/peterhcharlton/RRest/tree/master/RRest_v3.0/Publication_Specific_Scripts/ImP_SQI">https://github.com/peterhcharlton/RRest/tree/master/RRest_v3.0/Publication_Specific_Scripts/ImP_SQI</a></p> <p>License: The dataset (<a href="https://zenodo.org/record/3974113/files/mimic_imp_sqi_data.mat?download=1"><em>mimic_imp_sqi_data.mat</em></a>) is distributed under the terms specified in the accompanying LICENSE file. The scripts are distributed under the GNU General Public Licence (as specified towards&nbsp;the start of each file).</p> <p>Version 1.0: This version includes the submitted manuscript.</p> <p>&nbsp;</p>

openother-atAug 2020View details →
zenodo32/100

New high time resolution mutual impedance measurements

<p>=====================================================================================================<br> Author&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;: &nbsp;&nbsp; &nbsp;L. Bucciantini<br> Date &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;03/11/2022<br> Laboratory&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;CNRS-LPC2E, Orl&eacute;ans (France)<br> =====================================================================================================</p> <p>Dear reader, we thank you for your interest in our dataset. In this document, we describe what you will<br> find in it.</p> <p>In case you need help with using the dataset, or if you are interested in mutual impedance experiments,<br> do not hesitate to contact our team in Orl&eacute;ans (pierre.henri@cnrs-orleans.fr, pierre.henri@oca.eu)</p> <p>=====================================================================================================<br> Topic:<br> This dataset contains the outputs of numerical simulations and experimental tests performed<br> to test and validate two new mutual impedance instrumental modes: the chirp mode and the<br> multi-spectral mode. These modes have the objective of improving the time resolution of<br> mutual impedance measurements.</p> <p>These new instrumental modes are validated by comparing their measurements to the classic<br> instrumental mode of mutual impedance measuremetns, the so-called frequency sweep mode.</p> <p><br> Numerical model:<br> The numerical outputs are obtained from a numerical model based on the solution of the 1D-1V Vlasov-Poisson<br> system of equations. The scheme used to solve the model is the one developed<br> by Mangeney et al. (2002),&nbsp; A Numerical Scheme for the Integration of the Vlasov-Maxwell System of Equations. Journal of Computational Physics, (doi: https://doi.org/10.1006/jcph.2002.7071).<br> The 1D-1V Vlasov-Poisson version of this model is described in Henri, et al. (2010), Vlasov-Poisson<br> simulations of electrostatic parametric instability for localized Langmuir wave packets in the solar wind,<br> Journal of Geophysical Research (Space Physics), 115, 6106 (2010)</p> <p>Experimental testing facility:<br> The experimental outputs are obtained using the testing facility of CNRS-LPC2E space laboratory. It is<br> composed of a vacuum chamber, a pumping system and a plasma source. The pumps make vacuum in the<br> chamber (p=1e-5mbar). The plasma source generates a plasma flow that we use to test mutual impedance<br> instruments in a medium which is representative of Earth&#39;s ionosphere (100-2000 km of altitude).</p> <p>-----------------------------------------------------------------------------------------------------<br> Instrumental modes of interest</p> <p>frequency sweep (FS) mode : typical mode. Implemented for DFP-COMPLIMENT onboard Comet Interceptor</p> <p>chirp (CH) mode : new fast mode. It is based on the emission of only one period per frequency.</p> <p>multi-spectral (MS) mode : new fast mode. It is based on the simultaneous emission of multiple frequencies.</p> <p>-----------------------------------------------------------------------------------------------------<br> What is inside the dataset:</p> <p>The dataset is composed of 3 numerical and 6 experimental mutual impedance measurements.<br> The numerical measurements are obtained for the same plasma box but for different instrumental modes.<br> The experimental measurements are obtained for two different plasmas, monitored using the three different<br> instrumental modes.</p> <p>-----------------------------------------------------------------------------------------------------<br> List of directories:</p> <p><br> Numerical_CH, Numerical_MS:&nbsp;&nbsp; &nbsp;Each of these outputs corresponds to a mutual impedance measurement<br> Numerical_FS&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;performed using a different instrumental mode.<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;For MS and FS, inside the directory each folder corresponds to the<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;emission of a different frequency.</p> <p><br> Experimental&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;It contains a txt file with inside the mutual impedance spectra obtained<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;for two different plasmas</p> <p><br> -----------------------------------------------------------------------------------------------------<br> List of folders inside the directories:</p> <p>In the case of the numerical measurements, folders begin with the name &quot;000&quot; and have increasing index.</p> <p>------------------------------------------------------------------------------------------------------<br> List of files inside the folders for the numerical measurements:</p> <p>density_e.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electron density inside the box, in function of time (tempo)</p> <p>density_p.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion density inside the box, in function of time (tempo)</p> <p>E.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric field in the box, in function of time (tempo)</p> <p>qrho.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric potential in the box, in function of time (tempo)</p> <p>qrho_imposed.npz&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric charge imposed at the emitting antennas, in function of time (tempo)</p> <p>tempo.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time-vector for density, electric field, electric potential and charge vectors</p> <p>TEST_Luca.dat&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;parameters describing the characteristics of the simulated plasma box</p> <p><br> [<br> Note : the previous files can be opened as follows</p> <p>import numpy as np</p> <p>vector_file_name = np.load(&#39;file_name.npz&#39;) # Use these for the .npz files<br> characteristics_of_the_box = np.genfromtxt(&#39;TEST_Luca.dat&#39;,skip_header=1)</p> <p>]</p> <p>------------------------------------------------------------------------------------------------------<br> List of files inside the folders for the experimental measurements:</p> <p>data.txt &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;frequencies and amplitudes associated to the measurements.</p> <p>[<br> Note : the previous file can be directly included into a python script</p> <p>]</p> <p>-------------------------------------------------------------------------------------------------------<br> Characteristics of the simulated plasma box (TEST_Luca.dat)</p> <p>nx&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;amount of spatial grid points</p> <p>xl&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;physical size of the spatial box, expressed in Debye length</p> <p>tt_w&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time resolution for ion and electron density, electric field, electric potential and charge</p> <p>rap_m &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion-to-electron mass ratio</p> <p>R_p&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion-to-electron temperature ratio</p> <p>dt&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time step used to evolve in time the numerical simulation</p> <p>emission&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;emission frequency</p> <p>power&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;amplitude of the electric charge imposed at the emitting antennas</p> <p><br> (Note : all parameters not listed here but present inside the TEST_Luca.dat file correspond to additional<br> &nbsp;&nbsp; &nbsp;functionalities of the model. For the use of this dataset, they can be discarded.)</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p>

opencc-by-4.0Nov 2022View details →
zenodo32/100

Synthesized Impedance Spectra Measurements of Epithelial Tissue

<p>This dataset consists of synthetic impedance measurements on modeled epithelial tissue as described in [1]. Based on previous work, physiological tissue properties were estimated for the `HT29/B6`, `IPECJ 2`, and `MDCK I` cell lines [2]. In this way, appropriate ranges of cell model parameters could be determined both for physiological control conditions and after apical addition of the substance Nystatin. &nbsp;For each cell line and condition, 150,000 values were randomly selected within their ranges. For each sample, a spectral impedance measurement was synthesized for 42 frequencies between 1.3 Hz and 16.35 kHz. Furthermore, the measurements were scattered to account for deviations from the theoretical impedance value due to the experimental setup. For more details see [1].</p> <p><strong>Important</strong>: You are cordially invited to use this dataset for your research or teaching purposes.&nbsp;For example, to compare your impedance analysis approach with ours or to develop new machine learning methods. <strong>If you use this dataset for a scientific publication, please cite [1]</strong>, where the synthesis and original application of this dataset are described in detail. If you have any questions or remarks, please do not hesitate to contact me via email (bschindler at informatik.uni-leipzig.de).</p> <p>### Changelog ###</p> <p>version 1.2&nbsp;-&gt; statistical features recalculated (for incorrect variance and median-mean) and added (pairwise differences and ratios)</p> <p>version 1.1 -&gt; clean&nbsp;impedance spectra without error modeling were added.</p> <p>version 1.0 -&gt; initial upload</p> <p>### Sources ###<br> [1] B. Schindler, D. G&uuml;nzel, and T. Schmid, &ldquo;Transcending Two-Path Impedance Spectroscopy with Machine Learning:<br> A Computational Study on Modeling and Quantifying Electric Bipolarity of Epithelia,&ldquo; International Journal On Advances in Life Sciences 13(1-2), 2021 &nbsp;<br> [2] T. Schmid, &ldquo;Automatisierte Analyse von Impedanzspektren mittels konstruktivistischen maschinellen Lernens,&rdquo; Ph.D. dissertation, Universit&auml;t Leipzig, Germany, 2018. &nbsp;</p>

opencc-by-4.0Nov 2021View details →
zenodo32/100

Figure files for High-impedance surface acoustic wave resonators

<p>This repository contains .fig (MATLAB) files corresponding to the figures in&nbsp; &#39;High-impedance surface acoustic wave resonators.&#39;&nbsp;<br> The raw data are available from the corresponding author upon reasonable request.<br> &nbsp;</p>

opencc-by-4.0Jun 2023View details →
zenodo32/100

1D-1V Vlasov-Poisson Simulations of Mutual Impedance Experiments in the presence of small-scale and large-scale plasma inhomogeneities - PART 1

<p>=====================================================================================================<br> Author&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;: &nbsp;&nbsp; &nbsp;L. Bucciantini<br> Date &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;05/07/2023<br> Laboratory&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;CNRS-LPC2E, Orl&eacute;ans (France)<br> =====================================================================================================</p> <p>Dear reader, we thank you for your interest in our dataset. In this document, we describe what you will<br> find in it.</p> <p>In case you need help with using the dataset, or if you are interested in mutual impedance experiments,<br> do not hesitate to contact our team in Orl&eacute;ans (pierre.henri@cnrs-orleans.fr, pierre.henri@oca.eu)</p> <p>=====================================================================================================<br> Topic:<br> This dataset contains the outputs of numerical simulations performed to assess<br> the impact of plasma inhomogeneities on the diagnostic performance<br> of mutual impedance experiments.</p> <p><br> Numerical model:<br> The outputs are obtained from a numerical model based on the solution of the 1D-1V Vlasov-Poisson<br> system of equations. The scheme used to solve the model is the one developed<br> by Mangeney et al. (2002),&nbsp; A Numerical Scheme for the Integration of the Vlasov-Maxwell System of Equations. Journal of Computational Physics, (doi: https://doi.org/10.1006/jcph.2002.7071).<br> The 1D-1V Vlasov-Poisson version of this model is described in Henri, et al. (2010), Vlasov-Poisson<br> simulations of electrostatic parametric instability for localized Langmuir wave packets in the solar wind,<br> Journal of Geophysical Research (Space Physics), 115, 6106 (2010)<br> -----------------------------------------------------------------------------------------------------<br> What is inside the dataset:</p> <p>The dataset is composed of 7 different mutual impedance measurements, each corresponding to one<br> directory (see below). The measurements (i.e. directory) correspond to small-scale plasma inhomogeneities at different<br> positions with respect to the mutual impedance antennas, or to a large-scale plasma inhomogeneity.</p> <p>Each directory contains a number of folders. Each folder corresponds to the emission of a signal at<br> different frequency.<br> -----------------------------------------------------------------------------------------------------<br> List of directories:</p> <p>(Note : each directory corresponds to one mutual impedance measurement)</p> <p>L&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;These outputs correspond to one mutual impedance measurement in<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;small antenna emission amplitude, which corresponds to a linear<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;plasma response to the emission.</p> <p>s_xx &nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;Each of these outputs corresponds to one mutual impedance measurement in correspondance of<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;a small-scale plasma inhomogeneity at xx Debye lengths of distance from the emitting antenna<br> &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</p> <p>-----------------------------------------------------------------------------------------------------<br> List of folders inside the directories:</p> <p>Folders begin with the name &quot;000&quot; and have increasing index. Inside the same directory, each folder<br> represents a different simulation used to build the same mutual impedance measurement.</p> <p>------------------------------------------------------------------------------------------------------<br> List of files inside the folders:</p> <p>density_e.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electron density inside the box, in function of time (tempo)</p> <p>density_p.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion density inside the box, in function of time (tempo)</p> <p>E.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric field in the box, in function of time (tempo)</p> <p>qrho.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric potential in the box, in function of time (tempo)</p> <p>qrho_imposed.npz&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;electric charge imposed at the emitting antennas, in function of time (tempo)</p> <p>tempo.npz&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time-vector for density, electric field, electric potential and charge vectors</p> <p>TEST_Luca.dat&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;parameters describing the characteristics of the simulated plasma box</p> <p><br> [<br> Note : the previous files can be opened as follows</p> <p>import numpy as np</p> <p>vector_file_name = np.load(&#39;file_name.npz&#39;) # Use these for the .npz files<br> characteristics_of_the_box = np.genfromtxt(&#39;TEST_Luca.dat&#39;,skip_header=1)</p> <p>]</p> <p><br> -------------------------------------------------------------------------------------------------------<br> Characteristics of the simulated plasma box (TEST_Luca.dat)</p> <p>nx&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;amount of spatial grid points</p> <p>xl&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;physical size of the spatial box, expressed in Debye length</p> <p>tt_w&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time resolution for ion and electron density, electric field, electric potential and charge</p> <p>rap_m &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion-to-electron mass ratio</p> <p>R_p&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;ion-to-electron temperature ratio</p> <p>dt&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;time step used to evolve in time the numerical simulation</p> <p>emission&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;emission frequency</p> <p>power&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;:&nbsp;&nbsp; &nbsp;amplitude of the electric charge imposed at the emitting antennas</p> <p><br> (Note : all parameters not listed here but present inside the TEST_Luca.dat file correspond to additional<br> &nbsp;&nbsp; &nbsp;functionalities of the model. For the use of this dataset, they can be discarded.)</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p> <p>&nbsp;</p>

opencc-by-4.0Jul 2023View details →
zenodo32/100

Impedance spectroscopy of chiral symmetric topoelectrical circuits

<p>This code reproduces our results.</p>

opencc-by-4.0Sep 2023View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.