Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
145
datasets available to search
ShareScore release 0.9.0
Dataset results
145 results for “THEMIS”
THEMIS GBO All Sky Imager at Kapuskasing, ON, Canada. ASI Thumbnails Data.
THEMIS Ground All Sky Imager at Kapuskasing (49.39 deg GLat, 277.68 deg GLong): 32 x 32 pixel thumbnails for full ASI images. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours sun shades deploy to protect the CCD.
Chibougamau THEMIS Ground-based All Sky Imager; Full Resolution Images.
THEMIS Ground All Sky Imager at Chibougamau (49.81 deg GLat, 285.58 deg GLong): 256 x 256 pixel full resolution images of auroral oval. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours a sun shades deploy to protect the CCD.
THEMIS-D: Solid State Telescope (SST): Energy flux spectrogram, electron/ion ground-calculated fluxes (30 keV - 300 keV).
THEMIS-D: The Solid State Telescope (SST) measures the incoming intensity (flux per solid angle) of superthermal electrons and ions. The spacecraft is fitted with two units (heads), each SST unit has two pairs of opposing ion and electron sensors. Each single sensor covers an angle of 36 degrees. The units are oriented such that one pair is always centered in the rotation plane, the other oriented at a maximum angle of 54 degrees off the plane. Each pair of units are oriented opposite each other allowing both ion and electron sensors to sweep out a maximum of 92% of the sky (45x45 degree required Elevation by Azimuth FOV, 108x22 raw) . The ion and electron sensors primarily measure particles between 30-300 keV and 30-100 keV respectively with a maximum capability of 20-6000 keV and 25-1000 keV. Full distribution data is measured over 128 angles and 16 energy bins, reduced distribution uses 6 angles and 16 energy bins, and burst mode data has 64 angles in 16 energy bins. Matched and paired electron broom magnets produce quadrapole fields reducing magnetic contamination. A mechanical attenuator is used to increase the instruments dynamical range avoiding oversaturation near the plasma sheet edge.
THEMIS GBO All Sky Imager at Gakona, AK. ASI Thumbnails Data.
THEMIS Ground All Sky Imager at Gakona (62.39 deg GLat, 214.87 deg GLong): 32 x 32 pixel thumbnails for full ASI images. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours sun shades deploy to protect the CCD.
Yellowknife THEMIS Ground-based All Sky Imager; Full Resolution Images.
THEMIS Ground All Sky Imager at Yellowknife (62.52 deg GLat, 245.69 deg GLong): 256 x 256 pixel full resolution images of auroral oval. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours a sun shades deploy to protect the CCD.
Fort Simpson THEMIS Ground-based All Sky Imager; Full Resolution Images.
THEMIS Ground All Sky Imager at Fort Simpson (61.76 deg GLat, 238.77 deg GLong): 256 x 256 pixel full resolution images of auroral oval. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours a sun shades deploy to protect the CCD.
THEMIS GBO All Sky Imager at The Pas, MB, Canada. ASI Thumbnails Data.
THEMIS Ground All Sky Imager at The Pas (53.99 deg GLat, 259.06 deg GLong): 32 x 32 pixel thumbnails for full ASI images. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours sun shades deploy to protect the CCD.
THEMIS-B (P1/ARTEMIS-P1) Orbit (Ephemeris)
THEMIS-B Orbital Information provided via the Satellite Situation Center, SSCWeb, System and Services, Space Physics Data Facility, SPDF, GSFC, NASA
THEMIS-E: On Board spin fits (FIT) of Electric (EFI) and Magnetic (FGM) field. On-Board Spin-fit electric and magnetic field data
THEMIS-E: On Board spin fits of Electric (EFI) and Magnetic (FGM) fields. This file contains data EFI and FGM that has been despun on-board to 3 second resolution. It stores meta information like the number of points that contributed to each spin and the standard deviation of those points. For the EFI data it also stores variables with the Z component of the EFI data zeroed and the Z component of the EFI estimated using the E.B=0 equality. The need to use an estimated Z axis for the EFI is due to error in measurements from the EFI axial booms. These data are provided in DSL (despun spacecraft L-Z vector), GSM, and GSE coordinates.
Sanikiluaq THEMIS Ground-based All Sky Imager; Full Resolution Images.
THEMIS Ground All Sky Imager at Sanikiluaq (56.54 deg GLat, 280.77 deg GLong): 256 x 256 pixel full resolution images of auroral oval. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours a sun shades deploy to protect the CCD.
THEMIS GBO All Sky Imager at Inuvik, NT, Canada. ASI Thumbnails Data.
THEMIS Ground All Sky Imager at Inuvik (68.41 deg GLat, 226.23 deg GLong): 32 x 32 pixel thumbnails for full ASI images. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours sun shades deploy to protect the CCD.
THEMIS-A: Probe Electric Field Instrument and Search Coil Magnetometer Instrument, Digital Fields Board - digitally computed Filter Bank spectra and E12 peak and average in HF band (FBK).
The Filter Bank is part of the Digital fields board and provides band-pass filtering for EFI and SCM spectra as well as E12HF peak and average value calculations. The Filter Bank provides band-pass filtering for less computationally and power intensive spectra than the FFT would provide. The process is as follows: Signals are fed to the Filter Bank via a low-pass FIR filter with a cut-off frequency half that of the original signal maximum. The output is passed to the band-pass filters, is differenced from the original signal, then absolute value of the data is taken and averaged. The output from the low-pass filter is also sent to a second FIR filter with 2:1 decimation. This output is then fed back through the system. The process runs through 12 cascades for input at 8,192 samples/s and 13 for input at 16,384 samples/sec (EAC input only), reducing the signal and computing power by a factor 2 at each cascade. At each cascade a set of data is produced at a sampling frequency of 2^n from 2 Hz to the initial sampling frequency (frequency characteristics for each step are shown below in Table 1). The average from the Filter Bank is compressed to 8 bits with a pseudo-logarithmic encoder. The data is stored in sets of six frequency bins at 2.689 kHz, 572 Hz, 144.2 Hz, 36.2 Hz, 9.05 Hz, and 2.26 Hz. The average of the coupled E12HF signal and it's peak value are recorded over 62.5 ms windows (i.e. a 16 Hz sampling rate). Accumulation of values from signal 31.25 ms windows is performed externally. The analog signals fed into the FBK are E12DC and SCM1. Sensor and electronics design provided by UCB (J. W. Bonnell, F. S. Mozer), Digital Fields Board provided by LASP (R. Ergun), Search coil data provided by CETP (A. Roux). Table 1: Frequency Properties. Cascade Frequency content of Input Signal Low-pass Filter Cutoff Frequency Freuency Content of Low-pass Output Signal Filter Bank Frequency Band 0* 0 - 8 kHz 4 kHz 0 - 4 kHz 4 - 8 kHz 1 0 - 4 kHz 2 kHz 0 - 2 kHz 2 - 4 kHz 2 0 - 2 kHz 1 kHz 0 - 1 kHz 1 - 2 kHz 3 0 - 1 kHz 512 Hz 0 - 512 Hz 512 Hz - 1 kHz 4 0 - 512 Hz 256 Hz 0 - 256 Hz 256 - 512 Hz 5 0 - 256 Hz 128 Hz 0 - 128 Hz 128 - 256 Hz 6 0 - 128 Hz 64 Hz 0 - 64 Hz 64 - 128 Hz 7 0 - 64 Hz 32 Hz 0 - 32 Hz 32 - 64 Hz 8 0 - 32 Hz 16 Hz 0 - 16 Hz 16 - 32 Hz 9 0 - 16 Hz 8 Hz 0 - 8 Hz 8 - 16 Hz 10 0 - 8 Hz 4 Hz 0 - 4 Hz 4 - 8 Hz 11 0 - 4 Hz 2 Hz 0 - 2 Hz 2 - 4 Hz 12 0 - 2 Hz 1 Hz 0 - 1 Hz 1 - 2 Hz *Only available for 16,384 Hz sampling.
THEMIS-D: On Board spin fits (FIT) of Electric (EFI) and Magnetic (FGM) field. On-Board Spin-fit electric and magnetic field data
THEMIS-D: On Board spin fits of Electric (EFI) and Magnetic (FGM) fields. This file contains data EFI and FGM that has been despun on-board to 3 second resolution. It stores meta information like the number of points that contributed to each spin and the standard deviation of those points. For the EFI data it also stores variables with the Z component of the EFI data zeroed and the Z component of the EFI estimated using the E.B=0 equality. The need to use an estimated Z axis for the EFI is due to error in measurements from the EFI axial booms. These data are provided in DSL (despun spacecraft L-Z vector), GSM, and GSE coordinates.
The Pas THEMIS Ground-based All Sky Imager; Full Resolution Images.
THEMIS Ground All Sky Imager at The Pas (53.99 deg GLat, 259.06 deg GLong): 256 x 256 pixel full resolution images of auroral oval. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours a sun shades deploy to protect the CCD.
ODYSSEY THEMIS IR RDR V1.0
The THEMIS IR-RDR data set contains the calibrated thermal infrared observations. Each qube header includes basic parameters describing the observation and file specific details of the calibration process.
THEMIS-C: Solid State Telescope (SST): Energy flux spectrogram, electron/ion ground-calculated fluxes (30 keV - 300 keV).
THEMIS-C: The Solid State Telescope (SST) measures the incoming intensity (flux per solid angle) of superthermal electrons and ions. The spacecraft is fitted with two units (heads), each SST unit has two pairs of opposing ion and electron sensors. Each single sensor covers an angle of 36 degrees. The units are oriented such that one pair is always centered in the rotation plane, the other oriented at a maximum angle of 54 degrees off the plane. Each pair of units are oriented opposite each other allowing both ion and electron sensors to sweep out a maximum of 92% of the sky (45x45 degree required Elevation by Azimuth FOV, 108x22 raw) . The ion and electron sensors primarily measure particles between 30-300 keV and 30-100 keV respectively with a maximum capability of 20-6000 keV and 25-1000 keV. Full distribution data is measured over 128 angles and 16 energy bins, reduced distribution uses 6 angles and 16 energy bins, and burst mode data has 64 angles in 16 energy bins. Matched and paired electron broom magnets produce quadrapole fields reducing magnetic contamination. A mechanical attenuator is used to increase the instruments dynamical range avoiding oversaturation near the plasma sheet edge.
THEMIS-A: Solid State Telescope (SST): Energy flux spectrogram, electron/ion ground-calculated fluxes (30 keV - 300 keV).
THEMIS-A: The Solid State Telescope (SST) measures the incoming intensity (flux per solid angle) of superthermal electrons and ions. The spacecraft is fitted with two units (heads), each SST unit has two pairs of opposing ion and electron sensors. Each single sensor covers an angle of 36 degrees. The units are oriented such that one pair is always centered in the rotation plane, the other oriented at a maximum angle of 54 degrees off the plane. Each pair of units are oriented opposite each other allowing both ion and electron sensors to sweep out a maximum of 92% of the sky (45x45 degree required Elevation by Azimuth FOV, 108x22 raw) . The ion and electron sensors primarily measure particles between 30-300 keV and 30-100 keV respectively with a maximum capability of 20-6000 keV and 25-1000 keV. Full distribution data is measured over 128 angles and 16 energy bins, reduced distribution uses 6 angles and 16 energy bins, and burst mode data has 64 angles in 16 energy bins. Matched and paired electron broom magnets produce quadrapole fields reducing magnetic contamination. A mechanical attenuator is used to increase the instruments dynamical range avoiding oversaturation near the plasma sheet edge.
THEMIS-A: ESA electron/ion energy fluxes and moments
THEMIS-A: Electrostatic Analyzers (ESA): Electron/Ion Ground-Calculated Energy Fluxes (5eV - 25 keV for Ions and 6eV - 30 KeV for Electrons) and Moments (density, velocity, pressure, and temperature). The satellite has 2 modes Fast and Slow survey and 3 data types: FULL, REDUCED and BURST. FULL: 88 angles x 32 energies, time resolution of 128 spins(395 seconds) in slow survey and 32 spins(98 seconds) in fast survey. REDUCED: spin time resolution(3 sec) but angles averaged into 1 angular spectra x 32 energies in slow survey or 6 angular spectra(90 degree x 90 degree window) x 32 energies in fast survey. BURST: 88 angles x 32 energies and spin time resolution(3 sec) but only available sporadically and for short duration. Note that angular resolution affects moments since they are obtained integrating over the mode-specific angular distribution. These moments are processed on the ground. They should be regarded as approximations but will improve in quality as our processing routines are improved over the course of the mission to account for additional sources of variance.
THEMIS GBO All Sky Imager at McGrath, AK. ASI Thumbnails Data.
THEMIS Ground All Sky Imager at McGrath (62.95 deg GLat, 204.40 deg GLong): 32 x 32 pixel thumbnails for full ASI images. The ASI stations monitor a 170 degree field of view imaging the auroral oval at kilometer resolution. The ASI is comprised of a fisheye lens and CCD in a stainless steel enclosure topped with a transparent acrylic dome. The CCD has a resolution of 256 x 256 pixels. Exposure control ranges from 5 s to 1 ms although the typical data rate is one image every 3 seconds. Silicone heaters keep the instrument within the nominal temperature range. During daylight hours sun shades deploy to protect the CCD.
THEMIS-C: On Board moments: ESA and SST Electron/Ion moments, density, flux, velocity, pressure and temperature.
THEMIS-C On Board moments. On board data outputs include number density, particle flux, energy flux, and a six component symetric momentum flux tensor. Other moments are calculated from these partial moments on the ground adding total pressure, velocity, plasma temperature (measured as a three dimensional energy vector), and a six component symetric pressure tensor to the list of data products. Number density and total pressure are scalar outputs. Velocity is calculated in DSL, GSE, GSM, and MFA coordinates (coordinate descriptions are listed below in Table 1). Magnetic Field Aligned pressure tensor and temperature are calculated as well. All quantities are calculated for both ions and electrons from a combination of ESA and SST data. Moments data are taken at spin resolution in all ESA survey modes except burst. The spacecraft potential, as measure by the EFI, is used to correct for spacecraft charging by shifting the particle energies for calculation; this eliminates contamination from photo-electrons. Also, weighting factors are used to account for instrument specific energy and angle efficiency variations. Table 1: Coordinate Descriptions. Despun Sun - L-vector (DSL): Z-axis points towards the spin axis, the Y-axis is obtained from the cross product of Z and the Spacecraft-Sun direction as viewed from the probe. The X-axis sits in the Z-axis-Sun plane and completes a right handed system. Geocentric Solar Ecliptic (GSE): Z-axis is normal to the solar ecliptic, the X-axis points from earth towards the Sun, and Y complets a right handed system. Geocentric solar Magnetosphereic (GSM): X-axis points from Earth to the Sun, the Y-axis is orthogonal to the Earth's magnetic dipole and points towards the dusk side, and the X-Z plane contains the dipole axis. Magnetic Field Aligned (MFA): Z-axis points along magnetic field lines, the Y-axis is the orthonormal cross product of the Z-axis and a vector pointing towards the Sun, and the X-axis completes the right handed system.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.