Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
2,001
datasets available to search
ShareScore release 0.9.0
Dataset results
2,001 results for “x-rays”
Text-fig. 4. Synchrotron radiation X-ray tomographic microscopy (SRXTM) images of seeds of Canrightia foveolata sp. nov.; Catefica locality, Portugal. a–d) Volume renderings of abraded seeds in ventral (a), lateral (b, d) and apical (c) views showing the slightly protruding chalaza (arrows) and dense longitudinal grooves with shallow pits in the surface of the endotesta; e) Transverse section of seed (orthoslice xy0665) showing the irregular grooved surface of the endotesta (oi-en) and the tegmen comprised of two layers of thick-walled cells that surround the cells of the prominent endothelium (asterisk); f) Longitudinal section (orthoslice xz1195) through seed showing the thin-walled endothelium cells (asterisk) surrounded by the thicker cells of the outer tegmen and endotesta; g) Longitudinal section (orthoslice yz0727) through seed showing outlines of angular crystals evenly distributed in cells of the endotesta (oi-en); note the outer epidermis of the tegmen (ii-o) composed of thick-walled cells; h) Longitudinal section (orthoslice xz0940) of seed showing details of the chalazal region with course of the vascular bundle (vb), cells of the prominent endothelium (asterisk), crystalliferous endotesta of the outer integument (oi-en) and the distinct thick walled cells of the outer cells of the tegmen (ii-o); i) Longitudinal and tangential section (orthoslice yz0542) through the endotesta (oi-en) showing the outlines of densely spaced crystals. Specimens, Catefica 242-S175178 (a–c, e–h), Catefica 49-S175179 (d, i). Scale bars = 300 Μm (a–d), 100 Μm (e, f, h, i), 50 Μm (g). in The Early Cretaceous Mesofossil Flora Of Catefica, Portugal: Angiosperms
Text-fig. 4. Synchrotron radiation X-ray tomographic microscopy (SRXTM) images of seeds of Canrightia foveolata sp. nov.; Catefica locality, Portugal. a–d) Volume renderings of abraded seeds in ventral (a), lateral (b, d) and apical (c) views showing the slightly protruding chalaza (arrows) and dense longitudinal grooves with shallow pits in the surface of the endotesta; e) Transverse section of seed (orthoslice xy0665) showing the irregular grooved surface of the endotesta (oi-en) and the tegmen comprised of two layers of thick-walled cells that surround the cells of the prominent endothelium (asterisk); f) Longitudinal section (orthoslice xz1195) through seed showing the thin-walled endothelium cells (asterisk) surrounded by the thicker cells of the outer tegmen and endotesta; g) Longitudinal section (orthoslice yz0727) through seed showing outlines of angular crystals evenly distributed in cells of the endotesta (oi-en); note the outer epidermis of the tegmen (ii-o) composed of thick-walled cells; h) Longitudinal section (orthoslice xz0940) of seed showing details of the chalazal region with course of the vascular bundle (vb), cells of the prominent endothelium (asterisk), crystalliferous endotesta of the outer integument (oi-en) and the distinct thick walled cells of the outer cells of the tegmen (ii-o); i) Longitudinal and tangential section (orthoslice yz0542) through the endotesta (oi-en) showing the outlines of densely spaced crystals. Specimens, Catefica 242-S175178 (a–c, e–h), Catefica 49-S175179 (d, i). Scale bars = 300 Μm (a–d), 100 Μm (e, f, h, i), 50 Μm (g).
X-ray properties of high-redshift Radio Loud and Radio Quiet Quasars observed by Chandra
<p><a href="http://arxiv.org/abs/2301.02866">X-ray properties of high-redshift Radio Loud and Radio Quiet Quasars observed by Chandra</a></p> <p>The following data set presents the data used in our research paper "X-ray properties of high-redshift Radio Loud and Radio Quiet Quasars observed by Chandra " <a href="http://http://arxiv.org/abs/2301.02866">http://arxiv.org/abs/2301.02866</a>. These tables contain the X-rays parameters of our selected sample of quasars. The file name acronames are (RLQ: Radio Loud Quasars), (RQQ: Radio Quiet Quasars), and (RIQ: Radio Intermediate Quasars). The number in the files name indicates the number of quasars in this file. Each parameter has its corresponding data type, physical description, and unit.</p>
Text-fig. 23. Synchrotron radiation X-ray tomographic microscopy (SRXTM) images of Ibericarpus cuneiformis gen. et sp. nov.; Catefica locality, Portugal. a) Longitudinal section (orthoslice yz0827) showing fruitlet with apical stigmatic region and a single seed enclosed within the fruitlet wall that has a thick epidermal cuticle; note the tiny embryo (emb) internal to the micropyle (mi) and oriented toward the base of the fruitlet; b) Transverse section through apical part of two fruitlets (orthoslice xy0810) showing the fruitlet wall (fr) composed of small thin-walled cells covered by an epidermis of isodiametric cells (ep) with a thick outer cuticle (cu); c) Longitudinal section (orthoslice xz0370) through basal part of fruitlet perpendicular to section in (a) showing the micropyle (mi), embryo (emb) composed of tiny cells, and the thick cuticle (cu) covering the bulging cells of the fruitlet epidermis. Specimen, Catefica 50-S174907 (a–c). Scale bars = 300 Μm (a–c). in The Early Cretaceous Mesofossil Flora Of Catefica, Portugal: Angiosperms
Text-fig. 23. Synchrotron radiation X-ray tomographic microscopy (SRXTM) images of Ibericarpus cuneiformis gen. et sp. nov.; Catefica locality, Portugal. a) Longitudinal section (orthoslice yz0827) showing fruitlet with apical stigmatic region and a single seed enclosed within the fruitlet wall that has a thick epidermal cuticle; note the tiny embryo (emb) internal to the micropyle (mi) and oriented toward the base of the fruitlet; b) Transverse section through apical part of two fruitlets (orthoslice xy0810) showing the fruitlet wall (fr) composed of small thin-walled cells covered by an epidermis of isodiametric cells (ep) with a thick outer cuticle (cu); c) Longitudinal section (orthoslice xz0370) through basal part of fruitlet perpendicular to section in (a) showing the micropyle (mi), embryo (emb) composed of tiny cells, and the thick cuticle (cu) covering the bulging cells of the fruitlet epidermis. Specimen, Catefica 50-S174907 (a–c). Scale bars = 300 Μm (a–c).
Raw data for "Multimodal imaging of cubic Cu2O@Au nanocage formation via galvanic replacement using X-ray ptychography and nano diffraction"
<p><strong>Raw data for "Multimodal imaging of cubic Cu2O@Au nanocage formation via galvanic replacement using X-ray ptychography and nano diffraction"</strong></p> <p>The file "raw_data_ptychography_waxs.zip" contains one HDF5 archive for each scan. The archives are structured as follows:</p> <ul> <li>section experiment: <ul> <li>identifiers of the lightsource, beamline, beamtime, session number, and scan number</li> </ul> </li> <li>section measured: <ul> <li>N diffraction patterns of size 512x512 px used for ptychography</li> <li>N WAXS patterns of size 514x1030 px</li> <li>N scan positions in mm</li> <li>one detector mask of size 512x512 px used for ptychography</li> <li>one detector mask of size 514x1030 px used for WAXS</li> <li>slice separation in mm for multi slice reconstruction</li> </ul> </li> <li>section parameters: <ul> <li>distance between sample and forward detector (ptychography) in mm</li> <li>pixel size of forward detector (ptychography) in mm</li> <li>photon energy in keV</li> <li>cropping of diffraction patterns in px used for ptychographic reconstruction</li> </ul> </li> </ul> <p>The following lists show the scan numbers with their corresponding reaction times and slice separations for the in situ series recorded during growth of Cu<sub>2</sub>O nanocubes, as well as galvanic replacement with Au measured out of focus and in focus.</p> <p>Growth of Cu<sub>2</sub>O nanocubes:</p> <table> <tbody> <tr> <td><strong>scan number</strong></td> <td><strong>slice distance, mm</strong></td> <td><strong>reaction time, h</strong></td> </tr> <tr> <td>179</td> <td>1</td> <td>1.58</td> </tr> <tr> <td>185</td> <td>1</td> <td>3.59</td> </tr> <tr> <td>191</td> <td>1</td> <td>4.78</td> </tr> <tr> <td>192</td> <td>1</td> <td>5.21</td> </tr> <tr> <td>193</td> <td>1</td> <td>5.64</td> </tr> <tr> <td>194</td> <td>1</td> <td>6.08</td> </tr> <tr> <td>195</td> <td>1</td> <td>6.51</td> </tr> <tr> <td>196</td> <td>1</td> <td>6.94</td> </tr> <tr> <td>197</td> <td>1</td> <td>7.37</td> </tr> <tr> <td>198</td> <td>1</td> <td>7.81</td> </tr> <tr> <td>199</td> <td>1</td> <td>8.24</td> </tr> <tr> <td>200</td> <td>1</td> <td>8.67</td> </tr> <tr> <td>201</td> <td>1</td> <td>9.10</td> </tr> <tr> <td>202</td> <td>1</td> <td>9.53</td> </tr> <tr> <td>203</td> <td>1</td> <td>9.97</td> </tr> <tr> <td>204</td> <td>1</td> <td>10.41</td> </tr> <tr> <td>205</td> <td>1</td> <td>10.86</td> </tr> <tr> <td>207</td> <td>0.96</td> <td>11.53</td> </tr> <tr> <td>208</td> <td>0.94</td> <td>11.96</td> </tr> <tr> <td>209</td> <td>0.92</td> <td>12.41</td> </tr> <tr> <td>210</td> <td>0.9</td> <td>12.85</td> </tr> <tr> <td>211</td> <td>0.88</td> <td>13.29</td> </tr> <tr> <td>212</td> <td>0.86</td> <td>13.74</td> </tr> <tr> <td>213</td> <td>0.84</td> <td>14.19</td> </tr> <tr> <td>215</td> <td>0.8</td> <td>15.07</td> </tr> <tr> <td>216</td> <td>0.78</td> <td>15.50</td> </tr> <tr> <td>218</td> <td>0.74</td> <td>16.06</td> </tr> <tr> <td>219</td> <td>0.72</td> <td>16.50</td> </tr> <tr> <td>220</td> <td>0.7</td> <td>16.82</td> </tr> <tr> <td>221</td> <td>0.68</td> <td>17.08</td> </tr> <tr> <td>223</td> <td>0.64</td> <td>17.79</td> </tr> <tr> <td>225</td> <td>0.6</td> <td>18.53</td> </tr> </tbody> </table> <p>Galvanic replacement with Au measured out of focus:</p> <table> <tbody> <tr> <td><strong>scan number</strong></td> <td><strong>slice distance, mm</strong></td> <td><strong>reaction time, h</strong></td> </tr> <tr> <td>263</td> <td>1</td> <td>-0.53</td> </tr> <tr> <td>265</td> <td>1</td> <td>0.13</td> </tr> <tr> <td>266</td> <td>1</td> <td>0.38</td> </tr> <tr> <td>267</td> <td>1</td> <td>0.63</td> </tr> <tr> <td>268</td> <td>1</td> <td>0.89</td> </tr> <tr> <td>269</td> <td>1</td> <td>1.14</td> </tr> <tr> <td>270</td> <td>1</td> <td>1.40</td> </tr> <tr> <td>271</td> <td>1</td> <td>1.64</td> </tr> <tr> <td>272</td> <td>1</td> <td>1.90</td> </tr> <tr> <td>273</td> <td>1</td> <td>2.14</td> </tr> <tr> <td>274</td> <td>1</td> <td>2.39</td> </tr> <tr> <td>275</td> <td>1</td> <td>2.63</td> </tr> <tr> <td>276</td> <td>1</td> <td>2.87</td> </tr> <tr> <td>277</td> <td>1</td> <td>3.11</td> </tr> <tr> <td>278</td> <td>1</td> <td>3.35</td> </tr> <tr> <td>279</td> <td>1</td> <td>3.60</td> </tr> <tr> <td>280</td> <td>1</td> <td>3.84</td> </tr> <tr> <td>281</td> <td>1</td> <td>4.08</td> </tr> <tr> <td>282</td> <td>1</td> <td>4.32</td> </tr> <tr> <td>283</td> <td>1</td> <td>4.74</td> </tr> <tr> <td>284</td> <td>1</td> <td>5.15</td> </tr> <tr> <td>286</td> <td>1</td> <td>5.59</td> </tr> <tr> <td>287</td> <td>1</td> <td>6.01</td> </tr> <tr> <td>288</td> <td>1</td> <td>6.35</td> </tr> <tr> <td>289</td> <td>1</td> <td>6.74</td> </tr> <tr> <td>290</td> <td>1</td> <td>7.15</td> </tr> <tr> <td>291</td> <td>1</td> <td>7.55</td> </tr> <tr> <td>292</td> <td>1</td> <td>7.94</td> </tr> <tr> <td>293</td> <td>1</td> <td>8.35</td> </tr> <tr> <td>294</td> <td>1</td> <td>8.75</td> </tr> <tr> <td>295</td> <td>1</td> <td>9.16</td> </tr> <tr> <td>296</td> <td>1</td> <td>9.56</td> </tr> <tr> <td>297</td> <td>1</td> <td>9.96</td> </tr> </tbody> </table> <p>Galvanic replacement with Au measured in focus:</p> <table> <tbody> <tr> <td><strong>scan number</strong></td> <td><strong>slice distance, mm</strong></td> <td><strong>reaction time, h</strong></td> </tr> <tr> <td>117</td> <td>1</td> <td>0.33</td> </tr> <tr> <td>118</td> <td>1</td> <td>0.93</td> </tr> <tr> <td>119</td> <td>1</td> <td>1.51</td> </tr> <tr> <td>120</td> <td>1</td> <td>2.08</td> </tr> <tr> <td>121</td> <td>1</td> <td>2.66</td> </tr> <tr> <td>122</td> <td>1</td> <td>3.24</td> </tr> <tr> <td>123</td> <td>1</td> <td>3.87</td> </tr> <tr> <td>124</td> <td>1</td> <td>4.44</td> </tr> <tr> <td>125</td> <td>1</td> <td>5.02</td> </tr> <tr> <td>126</td> <td>1</td> <td>5.61</td> </tr> <tr> <td>127</td> <td>1</td> <td>6.19</td> </tr> <tr> <td>128</td> <td>1</td> <td>6.77</td> </tr> <tr> <td>129</td> <td>1</td> <td>7.35</td> </tr> <tr> <td>130</td> <td>1</td> <td>7.93</td> </tr> <tr> <td>131</td> <td>1</td> <td>8.50</td> </tr> </tbody> </table> <p>The files "waxs_detector_calibration_cu2o_growth.poni" and "waxs_detector_calibration_au_galvanic_replacement.poni" contain the PONI data to be used for azimuthal integration of WAXS patterns using the pyFAI library.</p> <p><strong>Ptychographic reconstructions</strong></p> <p>The file "ptychographic_reconstructions.zip" contains the ptychographic reconstructions shown in the article and supplementary information in tiff format.</p> <p>Stacks of images corresponding to time series:</p> <ul> <li>Figure 1b, 2: P06_Cu2O_growth_scans_00179-00225_entrance_window.tif</li> <li>Figure 1b, 2: P06_Cu2O_growth_scans_00179-00225_exit_window.tif</li> <li>Figure 1d, 4, 5: P06_Au_galvanic_replacement_de-focus_scans_00263-00297_exit_window.tif</li> <li>Figure 5c: P06_Au_galvanic_replacement_in-focus_scans_00117-00131_exit_window.tif</li> </ul> <p><strong>SEM and EDX</strong></p> <p>The file "SEM_EDX.zip" contains the SEM images and EDX maps shown in Figure 3 in png format. Subfolders indicate the reaction time.</p>
Dataset for the paper 'Probing for the host galaxies of the fast X-ray transients XRT 000519 and XRT 110103'
<p>This is a reproduction package for the paper 'Probing for the host galaxies of the fast X-ray transients XRT 000519 and XRT 110103'. Instructions are given in the readme file. Those are minimalistic instructions. Please get in touch with me (d.eappachen@sron.nl/deepakeappachen5@gmail.com) for more details.</p>
Catalogue of X-ray photon fluence spectra of electronic brachytherapy device Esteya manufactured by Elekta
<p>The catalogue was compiled from suitable data available in literature and from the data measured or created by the project "18NRM02 PRISM-eBT" (Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices; http://www.ebt-empir.eu/) of the European Metrology Programme for Innovation and Research (EMPIR).</p> <p>The main goal of the catalogue was to develop a set of harmonised reference X-ray qualities denoted as “eBT equivalent” that would be established for in-laboratory activities by the X-ray tubes usually available for calibration in calibration laboratories, but the tube voltage and the filter are specifically selected to simulate the energy spectrum of the corresponding eBT radiation as closely as possible at the reference point. </p> <p>The catalogue contains the following spectra:</p> <p>1) Measured spectrum in air, 100 cm source-to-detector distance<br> 2) Measured spectrum in air, 150 cm source-to-detector distance<br> 3) eBT-equivalent spectrum in air, 150 cm source-to-detector distance, calculated by SpekCalc software<br> 4) Intermediate results for eBT-equivalent spectrum in air, 150 cm source-to-detector distance, realized at VSL"</p>
Commercial P-Channel Power VDMOSFET as X-ray Dosimeter (raw data from journal article)
<p>This upload contains raw data from the manuscript "Commercial P-Channel Power VDMOSFET as X-ray Dosimeter". The manuscript was published in Electronics, 11(6):918, 2022.; DOI: https://doi.org/10.3390/electronics11060918</p> <p>The upload consists of a .pdf file of the manuscript and .opj files with raw data related to the figures in the manuscript.</p> <p>This work was partly supported by the European Union’s Horizon 2020 research and innovation programme (Grant No. 857558) and the Ministry of Education, Science and Technology Development of the Republic of Serbia (Project No. 43011).</p>
Fig. 5. X-ray ORTEP drawing for 2a in Meroterpenoids with diverse structures and anti-inflammatory activities from Rhododendron anthopogonoides
Fig. 5. X-ray ORTEP drawing for 2a.
Fig. 4. X-ray ORTEP plots for compounds 1 and 3 in Clerodane diterpenoids from Dodonaea viscosa and their inhibitory effects on ATP citrate lyase
Fig. 4. X-ray ORTEP plots for compounds 1 and 3.
Fig. 4. X-Ray ORTEP plots for 1, 3, 4, 6 in Cycloartane triterpenoids from Pseudolarix amabilis and their antiviral activity
Fig. 4. X-Ray ORTEP plots for 1, 3, 4, 6, and 7.
Fig. 4. X-ray crystallographic data for 1 in Triterpenoids from Liquidambar Fructus induced cell apoptosis via a PI3KAKT related signal pathway in SMMC7721 cancer cells
Fig. 4. X-ray crystallographic data for 1.
Instrumentation Neutron Activation Analysis & Proton Induced X-RAY Emission techniques supported with Machine learning analysis for rare earth/macro/micro elements correlation from O. Sativa Rice varieties in Senegal River valley
<p>data sheet INAA;results</p>
Characteristics of Rheumatoid Arthritis Patients With Atlantoaxial Synovitis Detected by Plain X-ray and MRI
ClinicalTrials.gov study NCT02774070. IPD Sharing: UNDECIDED. Countries: 0. Publications: 2.
Diagnostic Role of Chest Ultrasound in Children Presenting With Respiratory Distress in Pediatric Intensive Care Unit (PICU) Compared to Chest X-ray
ClinicalTrials.gov study NCT04328220. IPD Sharing: Not stated. Countries: 0. Publications: 5.
Comparison of Ultrasound and X-ray as Screening Tests for Diagnosis of Lower Extremity Stress Fracture.
ClinicalTrials.gov study NCT03116360. IPD Sharing: NO. Countries: 0. Publications: 14.
3D X-ray Motion Analysis of Ankle-foot Motion After Total Ankle Arthroplasty
ClinicalTrials.gov study NCT03575975. IPD Sharing: NO. Countries: 1. Publications: 0.
MetaNeb® Chest X-ray Study
ClinicalTrials.gov study NCT02871258. IPD Sharing: Not stated. Countries: 1. Publications: 0.
X-ray Dose Reduction Study for Endovascular Interventional Radiology
ClinicalTrials.gov study NCT01599741. IPD Sharing: Not stated. Countries: 1. Publications: 0.
Study of Monochromatic X-ray Mammography System
ClinicalTrials.gov study NCT07219797. IPD Sharing: NO. Countries: 1. Publications: 0.
Evaluation of X-ray, Acetabular Guides and CT in THR
ClinicalTrials.gov study NCT03072706. IPD Sharing: NO. Countries: 1. Publications: 0.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.